scholarly journals Towards a generalised development of synthetic CT images and assessment of their dosimetric accuracy

2019 ◽  
Vol 59 (2) ◽  
pp. 180-187
Author(s):  
Josefine Handrack ◽  
Mark Bangert ◽  
Christian Möhler ◽  
Tilman Bostel ◽  
Steffen Greilich
2019 ◽  
Vol 136 ◽  
pp. 56-63 ◽  
Author(s):  
Samaneh Kazemifar ◽  
Sarah McGuire ◽  
Robert Timmerman ◽  
Zabi Wardak ◽  
Dan Nguyen ◽  
...  

2015 ◽  
Vol 93 (5) ◽  
pp. 1154-1161 ◽  
Author(s):  
Eric Paradis ◽  
Yue Cao ◽  
Theodore S. Lawrence ◽  
Christina Tsien ◽  
Mary Feng ◽  
...  

2021 ◽  
Author(s):  
Yingqing Lyu ◽  
Yue Chen ◽  
Greta Mok

Abstract Background: Quantitative activity estimation is essential in targeted radionuclide therapy dosimetry. Misregistration between SPECT and CT images at the same imaging time point due to patient movement degrades accuracy. This work aims to study the mismatch effects between CT and SPECT data on attenuation correction (AC), volume-of-interest (VOI) delineation and registration for activity estimation.Methods: Nine 4D XCAT phantoms were generated at 1, 24, and 144 hrs post In-111 Zevalin injection, varying in activity distributions, body and organ sizes. Realistic noisy SPECT projections were generated by an analytical projection and reconstructed with quantitative OS-EM method. CT images were shifted from -5 to 5 voxels as well as according to clinical reference corresponding to SPECT images at each time point. For AC effect, mismatched CT images were used for AC in SPECT reconstruction while VOIs were mapped out from matched CTs. For VOI effect, target organs were mapped out using mismatched CTs with matched CTs for AC. For registration effect, non-rigid registrations were performed on sequential mismatched CTs to align corresponding SPECT images, with no AC and VOI mismatch. Bi-exponential curve fitting was performed to obtain time-integrated activity (TIA). Organ activity errors (%OAE) and TIA errors (%TIAE) were calculated.Results: According to clinical reference, %OAE was larger for organs near ribs for AC effect, e.g., -2.58%±0.81% for liver. For VOI effect, %OAE was larger for small and low uptake organs, e.g., -11.94%±10.34% for spleen. %OAE was proportional to mismatch magnitude, e.g., 4.77%±1.41%, 12.01%±3.97% and 42.81%±6.38% for 1-, 2-, and 5-voxel mismatch for lungs. For registration effect, %TIAE were larger when mismatch existed in more numbers of SPECT/CT images, while no substantial difference was observed when using mismatched CT at different time points for registration reference. %TIAE was highest for VOI, followed by registration and AC, e.g., 37.61%±5.08%, 14.25%±7.07% and 1.13%±0.90% respectively for kidneys.Conclusions: The mismatch between CT and SPECT images poses a significant impact on accuracy of quantitative activity estimation in dosimetry, attributed particularly from VOI delineation errors. It is recommended to perform registration between emission and transmission images at the same time point to ensure dosimetric accuracy.


2008 ◽  
Vol 7 (5) ◽  
pp. 341-347 ◽  
Author(s):  
C. Wang ◽  
M. Chao ◽  
L. Lee ◽  
L. Xing

Nowadays magnetic resonance imaging (MRI) has been profoundly used in radiotherapy (RT) planning to aid the contouring of targets and critical organs in brain and intracranial cases, which is attributable to its excellent soft tissue contrast and multi-planar imaging capability. However, the lack of electron density information in MRI, together with the image distortion issues, precludes its use as the sole image set for RT planning and dose calculation. The purpose of this preliminary study is to probe the feasibility and evaluate an MRI-based radiation dose calculation process by providing MR images the necessary electron density (ED) information from a patient's readily available diagnostic/staging computed tomography (CT) images using an image registration model. To evaluate the dosimetric accuracy of the proposed approach, three brain and three intracranial cases were selected retrospectively for this study. For each patient, the MR images were registered to the CT images, and the ED information was then mapped onto the MR images by in-house developed software generating a modified set of MR images. Another set of MR images with voxel values assigned with the density of water was also generated. The original intensity modulated radiation treatment (IMRT) plan was then applied to the two sets of MR images and the doses were calculated. The dose distributions from the MRI-based calculations were compared to that of the original CT-based calculation. In all cases, the MRI-based calculations with mapped ED yielded dose values very close (within 2%) to that of the CT-based calculations. The MRI-based calculations with voxel values assigned with water density indicated a dosimetric error of 3–5%, depending on the treatment site. The present approach offers a means of utilizing MR images for accurate dose calculation and affords a potential to eliminate the redundant simulation CT by planning a patient's treatment with only simulation MRI and any available diagnostic/staging CT data.


2018 ◽  
Vol 127 ◽  
pp. S1144-S1145
Author(s):  
J. Handrack ◽  
M. Bangert ◽  
C. Möhler ◽  
T. Bostel ◽  
S. Greilich

2016 ◽  
Vol 119 ◽  
pp. S72
Author(s):  
E. Persson ◽  
F. Nordström ◽  
C. Siversson ◽  
C. Ceberg

2017 ◽  
Vol 44 (9) ◽  
pp. 4687-4694 ◽  
Author(s):  
Abraam S. Soliman ◽  
Levi Burns ◽  
Amir Owrangi ◽  
Young Lee ◽  
William Y. Song ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document