A state-of-the-art review of an optimal sensor placement for contaminant warning system in a water distribution network

2018 ◽  
Vol 15 (10) ◽  
pp. 985-1000 ◽  
Author(s):  
Oluwaseye S. Adedoja ◽  
Yskandar Hamam ◽  
Baset Khalaf ◽  
Rotimi Sadiku
10.29007/whzr ◽  
2018 ◽  
Author(s):  
Armando Di Nardo ◽  
Carlo Giudicianni ◽  
Roberto Greco ◽  
Manuel Herrera ◽  
Giovanni Francesco Santonastaso ◽  
...  

Installing an efficient monitoring and control sensor system provides the possibility to carry out main tasks on Water Distribution Networks (WDNs) management and protection. Given the WDNs complexity, efficient numerical techniques are needed to support optimal monitoring system design. Generally, it is appropriate to locate sensors at highly connected places in the WDN with water flow reaching several parts of the network. This paper introduces a general method to support water utilities on the decision making process for an efficient water system monitoring. The proposal is based on graph spectral techniques that take advantage on spectrum properties of the adjacency matrix of the water distribution network graph. It is consequently created a novel tool-set of graph spectral techniques adapted to improve the water monitoring tasks and consequently simplify further sensor placement. This is approached with no need of hydraulic simulation, as data availability is often limited or not suitable to face anomaly events changing assets and distribution performance. A real water distribution network serving a town near to Naples is used to analyze the proposed graph spectral methodology. In order to test the proposed procedure, a comparison was made with a sensor layout obtained through a bi-objective optimization, through some performance indicators. The results confirm the effectiveness of the proposed spectral procedure.


2020 ◽  
Vol 12 (2) ◽  
pp. 723 ◽  
Author(s):  
Jiajia Wu ◽  
Donghui Ma ◽  
Wei Wang ◽  
Zhao Han

Sensor placement for disaster prevention for important users in urban water distribution networks is essential for post-earthquake monitoring and repair. Herein, we proposed a sensor placement approach for disaster prevention monitoring for important users, to (a) improve the fault diagnosis ability of the water distribution network and to (b) guarantee the function of emergency services for key nodes after an earthquake. First, an evaluation system of node users’ disaster prevention impact factors was presented to evaluate the node influence degree from three aspects: post-earthquake leakage, emergency support and topology structure; and the weight values of node users’ disaster prevention impact factors were obtained. Second, a post-earthquake hydraulic analysis model based on the pressure-driven demand was used to calculate the water shortage ratio of nodes. Third, using the three-way clustering integration method, the results of four clustering techniques were integrated to divide the monitoring domain in the water distribution network based on sensitivity analysis. Finally, on basis of the sensitivity matrix, the division of the monitoring area and the impact factors of node users’ disaster prevention were combined to place sensors for post-earthquake disaster prevention in the water distribution network. Detailed computational experiments for a real urban water network in China were performed and compared with the results of other traditional techniques to evaluate the performance of the proposed approach. The results show that the approach is better than traditional methods. It not only considers the actual hydraulic information of the water distribution network, but also the important user nodes after an earthquake, and is of great significance for emergency command and rescue and disaster relief after an earthquake in the city.


Proceedings ◽  
2018 ◽  
Vol 2 (11) ◽  
pp. 670 ◽  
Author(s):  
Carlo Ciaponi ◽  
Enrico Creaco ◽  
Armando Di Nardo ◽  
Michele Di Natale ◽  
Carlo Giudicianni ◽  
...  

Water network protection from accidental and intentional contamination is one of the most critical issues for preserving the citizen health. Recently, some techniques have been proposed in the literature to define the optimal sensor placement. On the other hand, through the definition of permanent DMAs (District Meter Areas), water network partitioning allows significant reduction in the number of exposed users through the full isolation of DMA. In this paper, the optimal sensor placement is coupled with water network partitioning in order to define the best location of isolation valves and control stations, to be closed and installed respectively. The proposed procedure is based on different procedures, and it was tested on a real water network, showing that it is possible both to mitigate the impact of a water contamination and simplify the sensor placement through the water network partitioning.


2017 ◽  
Vol 16 (5) ◽  
pp. 1071-1079 ◽  
Author(s):  
Andrei-Mugur Georgescu ◽  
Sanda-Carmen Georgescu ◽  
Remus Alexandru Madularea ◽  
Diana Maria Bucur ◽  
Georgiana Dunca

Sign in / Sign up

Export Citation Format

Share Document