Study on desiccant solution control strategies for efficient liquid desiccant air conditioning system control performance

2018 ◽  
Vol 25 (3) ◽  
pp. 322-335
Author(s):  
Siva Kumar Reddy Y ◽  
Karthik Balasubramanian ◽  
V. P. Chandramohan
2011 ◽  
Vol 43 (6) ◽  
pp. 1499-1507 ◽  
Author(s):  
Gaoming Ge ◽  
Fu Xiao ◽  
Xiaofeng Niu

2013 ◽  
Vol 671-674 ◽  
pp. 2515-2519
Author(s):  
Xue Mei Wang ◽  
Zhen Hai Wang ◽  
Xing Long Wu

This project aims to study the optimal control model of the ice-storage system which is theoretically close to the optimal control and also applicable to actual engineering. Using Energy Plus, the energy consumption simulation software, and the simple solution method of optimal control, researchers can analyze and compare the annual operation costs of the ice-storage air-conditioning system of a project in Beijing under different control strategies. Researchers obtained the power rates of the air-conditioning system in the office building under the conditions of chiller-priority and optimal contro1 throughout the cooling season. Through analysis and comparison, they find that after the implementation of optimal control, the annually saved power bills mainly result from non-design conditions, especially in the transitional seasons.


Energy ◽  
2016 ◽  
Vol 109 ◽  
pp. 180-189 ◽  
Author(s):  
Li Yinglin ◽  
Zhang Xiaosong ◽  
Tan Laizai ◽  
Zhang Zhongbin ◽  
Wu Wei ◽  
...  

Author(s):  
Ali Mohammad Jafarpour ◽  
Farivar Fazelpour ◽  
Seyyed Abbas Mousavi

AbstractIn this study an experimental design was developed to optimize the performance and structure of a membrane-based parallel-plate liquid desiccant dehumidifier used in air conditioning regeneration system which operates under high humidity weather conditions. We conducted a series of polymeric porous membranes with different compositions fabricated that were prepared with various weight percentages of polysulfone (PSU), mixed with N-methyl-2-pyrrolidone (NMP) and dimethyl form amide (DMF) solvents. Furthermore, the designed experiments were performed under various operating conditions, indicating that the dehumidification efficiency declines with increasing flow rate, temperature, and humidity. Consequently, a membrane with optimized porosity and moisture permeability was selected which resulted in eliminating the carryover of solution droplets in the air, largely due to separating the flow condition of liquid desiccant (Li Cl) and air. This specific design is also greatly benefited by removing the water vapor from the air stream. The results of mathematical model simulations indicate that the DMF solvent had higher dehumidification capability compared with that of NMP under the optimized operating conditions. Additionally, it can clarify the porosity of the membrane which plays a significant role in the overall performance. Therefore, the fabricated membrane produces fresh cool air, and it can be applied as a guiding sample for designing the membrane-based dehumidifier with improved performance.


2019 ◽  
Vol 111 ◽  
pp. 04042
Author(s):  
Nicolás Ablanque ◽  
Santiago Torras ◽  
Carles Oliet ◽  
Joaquim Rigola ◽  
Carlos-David Pérez-Segarra

The simulation of HVAC systems is a powerful tool to improve the energy efficiency in buildings. The modelling of such systems faces several obstacles due to both the physical phenomenology present and the numerical resolution difficulties. The present work is an attempt to develop a robust, fast, and accurate model for HVAC systems that can interact with the other relevant systems involved in buildings thermal management. The whole system model has been developed in the form of libraries under the Modelica language to exploit its advantageous characteristics: object-oriented programming, equationbased modelling, and handling of multi-physics. The global resolution is carried out dynamically so that not only steady-state predictions can be conducted but also control strategies can be studied over meaningful periods of time. This latter aspect is crucial for optimizing energy savings. The libraries include models for all the system individual components such as pumps, compressors or heat exchangers (operating with twophase flows and/or moist air) and also models assemblies to account for vapour compression units and liquid circuits. An illustrative example of an indirect air conditioning system is detailed in the present work in order to highlight the model potential.


Sign in / Sign up

Export Citation Format

Share Document