hvac systems
Recently Published Documents


TOTAL DOCUMENTS

1147
(FIVE YEARS 382)

H-INDEX

45
(FIVE YEARS 8)

2022 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Femi Emmanuel Adeosun ◽  
Ayodeji Emmanuel Oke

Purpose In recent times, the construction industry is being influenced by technological innovations when delivering a better, more effective and efficient desired project, cyber-physical systems (CPSs) offer a coupling of the physical and engineered systems by monitoring, coordinating, controlling and integrating their operations. This study aims to examine the level of awareness of professionals and usage of CPSs for construction projects in Nigerian construction industry. Design/methodology/approach The target population for this study was the professionals in the construction industry consisting Architects, Quantity Surveyors, Engineers and Builders. Data collection was through the use of a structured questionnaire administered to the target population. The data was analyzed by using statistical tools. Findings This study concluded that the construction professionals in the Nigerian construction industry are mostly aware about the heating, ventilation and air conditioning (HVAC) systems, global positioning system, microphone, speakers and camera as the most widely used CPSs in construction industry. HVAC systems was also found to be the mostly adopted technologies in the construction industry. Originality/value This study recommended that platforms that increase the awareness and encourage the usage of CPSs in construction industry should be encouraged by stakeholders concerned with management of construction projects. Such include electronic construction and adoption of blockchain technology.


Energies ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 341
Author(s):  
Amir Rafati ◽  
Hamid Reza Shaker ◽  
Saman Ghahghahzadeh

Heat, ventilation, and air conditioning (HVAC) systems are some of the most energy-intensive equipment in buildings and their faulty or inefficient operation can significantly increase energy waste. Non-Intrusive Load Monitoring (NILM), which is a software-based tool, has been a popular research area over the last few decades. NILM can play an important role in providing future energy efficiency feedback and developing fault detection and diagnosis (FDD) tools in smart buildings. Therefore, the review of NILM-based methods for FDD and the energy efficiency (EE) assessment of HVACs can be beneficial for users as well as buildings and facilities operators. To the best of the authors’ knowledge, this paper is the first review paper on the application of NILM techniques in these areas and highlights their effectiveness and limitations. This review shows that even though NILM could be successfully implemented for FDD and the EE evaluation of HVACs, and enhance the performance of these techniques, there are many research opportunities to improve or develop NILM-based FDD methods to deal with real-world challenges. These challenges and future research works are also discussed in-depth.


Author(s):  
Farhad Forouharmajd ◽  
Shiva Soury ◽  
Mehran Mokhtari ◽  
Zahra Mohammadi

Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods: In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration assessment of the building was conducted in the other steps to compare with guidelines. In the next step, isolation method was used to control vibration. By placing the isolator on the duct wall, the accelerometer was located on the body of the duct wall and the value of vibration was measured in a millimeter per second. All stages of the experiment were performed in the Faculty of Health of Isfahan University of Medical Sciences in 2018. Results: The maximum vibration velocity reduction in the building was related to the frequency of 68 Hz, which reached 33 mm/s after isolation. In addition, the fan vibration at 485 Hz was equal to 2.1 m /s, which decreased to 2 mm /s after isolation. Conclusion: Comparison of vibration after fan isolation with standard showed that this method has been effective in reducing the fan vibration resulting in the vibration to reach below the standard.


Energies ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 313
Author(s):  
Mieczysław Porowski ◽  
Monika Jakubiak

This article presents approximating relations defining energy-optimal structures of the HVAC (Heating, Ventilation, Air Conditioning) system for cleanrooms as a function of key constant parameters and energy-optimal control algorithms for various options of heat recovery and external climates. The annual unit primary energy demand of the HVAC system for thermodynamic air treatment was adopted as the objective function. Research was performed for wide representative variability ranges of key constant parameters: cleanliness class—Cs (ISO5÷ISO8), unit cooling loads —q˙j (100 ÷ 500) W/m2 and percentage of outdoor air—αo (5 ÷ 100)%. HVAC systems are described with vectors x¯ with coordinates defined by constant parameters and decision variables, and the results are presented in the form of approximating functions illustrating zones of energy-optimal structures of the HVAC system x¯* = f (Cs, q˙j, αo). In the optimization procedure, the type of heat recovery as an element of optimal structures of the HVAC system and algorithms of energy-optimal control were defined based on an objective function and simulation models. It was proven that using heat recovery is profitable only for HVAC systems without recirculation and with internal recirculation (savings of 5 ÷ 66%, depending on the type of heat recovery and the climate), while it is not profitable (or generates losses) for HVAC systems with external recirculation or external and internal recirculation at the same time.


Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 262
Author(s):  
Archana Semwal ◽  
Rajesh Elara Elara Mohan ◽  
Lee Ming Jun Melvin ◽  
Povendhan Palanisamy ◽  
Chanthini Baskar ◽  
...  

Periodic inspection of false ceilings is mandatory to ensure building and human safety. Generally, false ceiling inspection includes identifying structural defects, degradation in Heating, Ventilation, and Air Conditioning (HVAC) systems, electrical wire damage, and pest infestation. Human-assisted false ceiling inspection is a laborious and risky task. This work presents a false ceiling deterioration detection and mapping framework using a deep-neural-network-based object detection algorithm and the teleoperated `Falcon’ robot. The object detection algorithm was trained with our custom false ceiling deterioration image dataset composed of four classes: structural defects (spalling, cracks, pitted surfaces, and water damage), degradation in HVAC systems (corrosion, molding, and pipe damage), electrical damage (frayed wires), and infestation (termites and rodents). The efficiency of the trained CNN algorithm and deterioration mapping was evaluated through various experiments and real-time field trials. The experimental results indicate that the deterioration detection and mapping results were accurate in a real false-ceiling environment and achieved an 89.53% detection accuracy.


2021 ◽  
Author(s):  
Corneliu Arsene

The electrical generation and transmission infrastructures of many countries are under increased pressure. This partially reflects the move towards low carbon economies and the increased reliance on renewable power generation systems. There has been a reduction in the use of traditional fossil fuel generation systems, which provide a stable base load, and this has been replaced with more unpredictable renewable generation. As a consequence, the available load on the grid is becoming more unstable. To cope with this variability, the UK National Grid has placed emphasis on the investigation of various technical mechanisms (e.g. implementation of smart grids, energy storage technologies, auxiliary power sources, Demand Side Response (DSR)), which may be able to prevent critical situations, when the grid may become sometimes unstable. The successful implementation of these mechanisms may require large numbers of electrical consumers (e.g. HVAC systems, food refrigeration systems) for example to make additional investments in energy storage technologies (i.e. food refrigeration systems) or to integrate their electrical demand from industrial processes into the National Grid (i.e. HVAC systems). However, for food refrigeration systems, during these critical situations, even if the thermal inertia within refrigeration systems may maintain effective performance of the device for a short period of time (e.g. under 1 minute) when the electrical input load into the system is reduced, this still carries the paramount risk of food safety even for very short periods of time (e.g. 1 under minute). Therefore before considering any future actions (e.g. investing in energy storage technologies) to prevent the critical situations when grid becomes unstable, it is also needed to understand during the normal use how the temperature profiles evolve along the time inside these massive networks of food refrigeration systems during either shorter (i.e. minutes) or longer periods of time (i.e. days, months) and this paper presents this.


PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0259996
Author(s):  
Rongchen Dai ◽  
Shan Liu ◽  
Qiushuang Li ◽  
Hanting Wu ◽  
Li Wu ◽  
...  

Objectives To evaluate (1) the relationship between heating, ventilation, and air conditioning (HVAC) systems and bioaerosol concentrations in hospital rooms, and (2) the effectiveness of laminar air flow (LAF) and high efficiency particulate air (HEPA) according to the indoor bioaerosol concentrations. Methods Databases of Embase, PubMed, Cochrane Library, MEDLINE, and Web of Science were searched from 1st January 2000 to 31st December 2020. Two reviewers independently extracted data and assessed the quality of the studies. The samples obtained from different areas of hospitals were grouped and described statistically. Furthermore, the meta-analysis of LAF and HEPA were performed using random-effects models. The methodological quality of the studies included in the meta-analysis was assessed using the checklist recommended by the Agency for Healthcare Research and Quality. Results The mean CFU/m3 of the conventional HVAC rooms and enhanced HVAC rooms was lower than that of rooms without HVAC systems. Furthermore, the use of the HEPA filter reduced bacteria by 113.13 (95% CI: -197.89, -28.38) CFU/m3 and fungi by 6.53 (95% CI: -10.50, -2.55) CFU/m3. Meanwhile, the indoor bacterial concentration of LAF systems decreased by 40.05 (95% CI: -55.52, -24.58) CFU/m3 compared to that of conventional HVAC systems. Conclusions The HVAC systems in hospitals can effectively remove bioaerosols. Further, the use of HEPA filters is an effective option for areas that are under-ventilated and require additional protection. However, other components of the LAF system other than the HEPA filter are not conducive to removing airborne bacteria and fungi. Limitation of study Although our study analysed the overall trend of indoor bioaerosols, the conclusions cannot be extrapolated to rare, hard-to-culture, and highly pathogenic species, as well as species complexes. These species require specific culture conditions or different sampling requirements. Investigating the effects of HVAC systems on these species via conventional culture counting methods is challenging and further analysis that includes combining molecular identification methods is necessary. Strength of the study Our study was the first meta-analysis to evaluate the effect of HVAC systems on indoor bioaerosols through microbial incubation count. Our study demonstrated that HVAC systems could effectively reduce overall bioaerosol concentrations to maintain better indoor air quality. Moreover, our study provided further evidence that other components of the LAF system other than the HEPA filter are not conducive to removing airborne bacteria and fungi. Practical implication Our research showed that HEPA filters are more effective at removing bioaerosols in HVAC systems than the current LAF system. Therefore, instead of opting for the more costly LAF system, a filter with a higher filtration rate would be a better choice for indoor environments that require higher air quality; this is valuable for operating room construction and maintenance budget allocation.