The use of a reference tissue arterial input function with low-temporal-resolution DCE-MRI data

2010 ◽  
Vol 55 (16) ◽  
pp. 4871-4883 ◽  
Author(s):  
M Heisen ◽  
X Fan ◽  
J Buurman ◽  
N A W van Riel ◽  
G S Karczmar ◽  
...  
2018 ◽  
Vol 81 (3) ◽  
pp. 1955-1963 ◽  
Author(s):  
Leonidas Georgiou ◽  
Daniel J. Wilson ◽  
Nisha Sharma ◽  
Timothy J. Perren ◽  
David L. Buckley

2020 ◽  
Author(s):  
Naoyuki Obokata ◽  
Chie Seki ◽  
Takeshi Hirata ◽  
Jun Maeda ◽  
Hideki Ishii ◽  
...  

AbstractPurposePhosphodiesterase (PDE) 7 is a potential therapeutic target for neurological and inflammatory diseases, although in-vivo visualization of PDE7 has not been successful. In this study, we aimed to develop [11C]MTP38 as a novel positron emission tomography (PET) ligand for PDE7.Methods[11C]MTP38 was radiosynthesized by 11C-cyanation of a bromo precursor with [11C]HCN. PET scans of rat and rhesus monkey brains and in-vitro autoradiography of brain sections derived from these species were conducted with [11C]MTP38. In monkeys, dynamic PET data were analyzed with an arterial input function to calculate the total distribution volume (VT). The non-displaceable binding potential (BPND) in the striatum was also determined by a reference tissue model with cerebellar reference. Finally, striatal occupancy of PDE7 by an inhibitor was calculated in monkeys according to changes in BPND.Results[11C]MTP38 was synthesized with radiochemical purity ≥ 99.4% and molar activity of 38.6 ± 12.6 GBq/μmol. Autoradiography revealed high radioactivity in the striatum and its reduction by non-radiolabeled ligands, in contrast with unaltered autoradiographic signals in other regions. In-vivo PET after radioligand injection to rats and monkeys demonstrated that radioactivity was rapidly distributed to the brain and intensely accumulated in the striatum relative to the cerebellum. Correspondingly, estimated VT values in the monkey striatum and cerebellum were 3.59 and 2.69 mL/cm3, respectively. The cerebellar VT value was unchanged by pretreatment with unlabeled MTP38. Striatal BPND was reduced in a dose-dependent manner after pretreatment with MTP-X, a PDE7 inhibitor. Relationships between PDE7 occupancy by MTP-X and plasma MTP-X concentration could be described by Hill’s sigmoidal function.ConclusionWe have provided the first successful preclinical demonstration of in-vivo PDE7 imaging with a specific PET radioligand. [11C]MTP38 is a feasible radioligand for evaluating PDE7 in the brain and is currently being applied to a first-in-human PET study.


2016 ◽  
Vol 43 (6Part25) ◽  
pp. 3644-3644
Author(s):  
N Majtenyi ◽  
H Gabrani-Juma ◽  
R Klein ◽  
RA deKemp ◽  
G Cron ◽  
...  

2004 ◽  
Vol 24 (6) ◽  
pp. 600-611 ◽  
Author(s):  
Koichi Sato ◽  
Kiyoshi Fukushi ◽  
Hitoshi Shinotoh ◽  
Shinichiro Nagatsuka ◽  
Noriko Tanaka ◽  
...  

The applicability of two reference tissue-based analyses without arterial blood sampling for the measurement of brain regional acetylcholinesterase (AChE) activity using N-[11C]methylpiperidin-4-yl propionate ([11C]MP4P) was evaluated in 12 healthy subjects. One was a linear least squares analysis derived from Blomqvist's equation, and the other was the analysis of the ratio of target-tissue radioactivity relative to reference-tissue radioactivity proposed by Herholz and coworkers. The standard compartment analysis using arterial input function provided reliable quantification of k3 (an index of AChE activity) estimates in regions with low (neocortex and hippocampus), moderate (thalamus), and high (cerebellum) AChE activity with a coefficient of variation (COV) of 12% to 19%. However, the precise k3 value in the striatum, where AChE activity is the highest, was not obtained. The striatum was used as a reference because its time-radioactivity curve was proportional to the time integral of the arterial input function. Reliable k3 estimates were also obtained in regions with low-to-moderate AChE activity with a COV of less than 21% by striatal reference analyses, though not obtained in the cerebellum. Shape analysis, the previous method of direct k3 estimation from the shape of time-radioactivity data, gave k3 estimates in the cortex and thalamus with a somewhat larger COV. In comparison with the standard analysis, a moderate overestimation of k3 by 9% to 18% in the linear analysis and a moderate underestimation by 2% to 13% in the Herholz method were observed, which were appropriately explained by the results of computer simulation. In conclusion, simplified kinetic analyses are practical and useful for the routine analysis of clinical [11C]MP4P studies and are nearly as effective as the standard analysis for detecting regions with abnormal AChE activity.


2007 ◽  
Vol 58 (6) ◽  
pp. 1266-1275 ◽  
Author(s):  
Cheng Yang ◽  
Gregory S. Karczmar ◽  
Milica Medved ◽  
Walter M. Stadler

2012 ◽  
Vol 39 (6Part3) ◽  
pp. 3615-3616 ◽  
Author(s):  
J Onxley ◽  
D Yoo ◽  
N Muradyan ◽  
J MacFall ◽  
D Brizel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document