Linearity measurements of critical Johnson noise thermometer components with low-distortion multitones from a Josephson arbitrary waveform synthesizer

Author(s):  
Marco Kraus ◽  
Dietmar Drung ◽  
Christian Krause ◽  
Luis Palafox ◽  
Ralf Behr
Metrologia ◽  
2009 ◽  
Vol 46 (5) ◽  
pp. 512-524 ◽  
Author(s):  
Jifeng Qu ◽  
S P Benz ◽  
H Rogalla ◽  
D R White

2009 ◽  
Vol 10 (9) ◽  
pp. 849-858 ◽  
Author(s):  
Samuel Benz ◽  
D. Rod White ◽  
JiFeng Qu ◽  
Horst Rogalla ◽  
Weston Tew

Author(s):  
Alessio Pollarolo ◽  
Weston Tew ◽  
Horst Rogalla ◽  
Jason M. Underwood ◽  
Samuel P. Benz

Metrologia ◽  
2009 ◽  
Vol 46 (5) ◽  
pp. 409-415 ◽  
Author(s):  
Luca Callegaro ◽  
Vincenzo D'Elia ◽  
Marco Pisani ◽  
Alessio Pollarolo

2020 ◽  
Vol 225 ◽  
pp. 03001
Author(s):  
Jonathan V. Pearce ◽  
Paul Bramley ◽  
David Cruickshank

Existing temperature sensors such as thermocouples and platinum resistance thermometers suffer from calibration drift, especially in harsh environments, due to mechanical and chemical changes (and transmutation in the case of nuclear applications). A solution to the drift problem is to use temperature sensors based on fundamental thermometry (primary thermometers) where the measured property is related to absolute temperature by a fundamental physical law. A Johnson noise thermometer is such a sensor and uses the measurement of the extremely small thermal voltage noise signals generated by any resistive element to determine temperature using the Johnson-Nyquist equation. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material, which makes it ideally suited to long-term temperature measurement in harsh environments. These can include reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have achieved commercialization because of technical difficulties. We describe the results of a collaboration between the National Physical Laboratory and Metrosol Limited, which has led to a new technique for measuring Johnson noise that overcomes the previous problems that have prevented commercialization. The results from a proof-of-principle prototype that demonstrates performance commensurate with the needs of nuclear applications is presented, together with details of progress towards the commercialization of the technology. The development partners have effected a step change in the application of primary thermometry to industrial applications and seek partners for field trials and further exploitation.


Sign in / Sign up

Export Citation Format

Share Document