A Monte-Carlo study to assess the effect of 1.5 T magnetic fields on the overall robustness of pencil-beam scanning proton radiotherapy plans for prostate cancer

2017 ◽  
Vol 62 (21) ◽  
pp. 8470-8482 ◽  
Author(s):  
Christopher Kurz ◽  
Guillaume Landry ◽  
Andreas F Resch ◽  
George Dedes ◽  
Florian Kamp ◽  
...  
2012 ◽  
Vol 57 (10) ◽  
pp. 2829-2842 ◽  
Author(s):  
Stephen J Dowdell ◽  
Benjamin Clasie ◽  
Nicolas Depauw ◽  
Peter Metcalfe ◽  
Anatoly B Rosenfeld ◽  
...  

2019 ◽  
Vol 63 (6) ◽  
pp. 829-835 ◽  
Author(s):  
Jiří Kubeš ◽  
Vladimir Vondráček ◽  
Michal Andrlik ◽  
Matěj Navrátil ◽  
Silvia Sláviková ◽  
...  

2016 ◽  
Vol 43 (3) ◽  
pp. 1462-1472 ◽  
Author(s):  
Frances C. Charlwood ◽  
Adam H. Aitkenhead ◽  
Ranald I. Mackay

2017 ◽  
Vol 18 (2) ◽  
pp. 44-49 ◽  
Author(s):  
Liyong Lin ◽  
Sheng Huang ◽  
Minglei Kang ◽  
Petri Hiltunen ◽  
Reynald Vanderstraeten ◽  
...  

2016 ◽  
Vol 119 ◽  
pp. S459-S460 ◽  
Author(s):  
J. Scherman Rydhög ◽  
R. Perrin ◽  
R. Irming Jølck ◽  
T. Lomax ◽  
F. Gagnon-Moisan ◽  
...  

2018 ◽  
Vol 45 (9) ◽  
pp. 4011-4019 ◽  
Author(s):  
Maryam Moteabbed ◽  
Alexei Trofimov ◽  
Fazal H. Khan ◽  
Yi Wang ◽  
Gregory C. Sharp ◽  
...  

Author(s):  
Yeon Soo Yeom ◽  
Keith Tchadwick Griffin ◽  
Matthew M Mille ◽  
Choonik Lee ◽  
Shannon O'Reilly ◽  
...  

Abstract Objective: We conducted a Monte Carlo study to comprehensively investigate the fetal dose resulting from proton pencil beam scanning (PBS) craniospinal irradiation (CSI) during pregnancy. Approach: The gestational-age dependent pregnant phantom series developed at the University of Florida (UF) were converted into DICOM-RT format (CT images and structures) and imported into a treatment planning system (TPS) (Eclipse v15.6) commissioned to a IBA PBS nozzle. A proton PBS CSI plan (prescribed dose: 36 Gy) was created on the phantoms. The TOPAS MC code was used to simulate the proton PBS CSI on the phantoms, for which MC beam properties at the nozzle exit (spot size, spot divergence, mean energy, and energy spread) were matched to IBA PBS nozzle beam measurement data. We calculated mean absorbed doses for 28 organs and tissues and whole body of the fetus at eight gestational ages (8, 10, 15, 20, 25, 30, 35, and 38 weeks). For contextual purposes, the fetal organ/tissue doses from the treatment planning CT scan of the mother’s head and torso were estimated using the National Cancer Institute dosimetry system for CT (NCICT, Version 3) considering a low-dose CT protocol (CTDIvol: 8.97 mGy). Main Results: The majority of the fetal organ/tissue doses from the proton PBS CSI treatment fell within a range of 3 to 6 mGy. The fetal organ/tissue doses for the 38-week phantom showed the largest variation with the doses ranging from 2.9 mGy (adrenals) to 8.2 mGy (eye lenses) while the smallest variation ranging from 3.2 mGy (oesophagus) to 4.4 mGy (brain) was observed for the doses for the 20-week phantom. The fetal whole-body dose ranged from 3.7 mGy (25 weeks) to 5.8 mGy (8 weeks). Most of the fetal doses from the planning CT scan fell within a range of 7 to 13 mGy, approximately 2-to-9 times lower than the fetal dose equivalents of the proton PBS CSI treatment (assuming a quality factor of 7). Significance: The fetal organ/tissue doses observed in the present work will be useful for one of the first clinically informative predictions on the magnitude of fetal dose during proton PBS CSI during pregnancy.


Sign in / Sign up

Export Citation Format

Share Document