planning ct
Recently Published Documents


TOTAL DOCUMENTS

263
(FIVE YEARS 88)

H-INDEX

20
(FIVE YEARS 3)

Author(s):  
Yeon Soo Yeom ◽  
Keith Tchadwick Griffin ◽  
Matthew M Mille ◽  
Choonik Lee ◽  
Shannon O'Reilly ◽  
...  

Abstract Objective: We conducted a Monte Carlo study to comprehensively investigate the fetal dose resulting from proton pencil beam scanning (PBS) craniospinal irradiation (CSI) during pregnancy. Approach: The gestational-age dependent pregnant phantom series developed at the University of Florida (UF) were converted into DICOM-RT format (CT images and structures) and imported into a treatment planning system (TPS) (Eclipse v15.6) commissioned to a IBA PBS nozzle. A proton PBS CSI plan (prescribed dose: 36 Gy) was created on the phantoms. The TOPAS MC code was used to simulate the proton PBS CSI on the phantoms, for which MC beam properties at the nozzle exit (spot size, spot divergence, mean energy, and energy spread) were matched to IBA PBS nozzle beam measurement data. We calculated mean absorbed doses for 28 organs and tissues and whole body of the fetus at eight gestational ages (8, 10, 15, 20, 25, 30, 35, and 38 weeks). For contextual purposes, the fetal organ/tissue doses from the treatment planning CT scan of the mother’s head and torso were estimated using the National Cancer Institute dosimetry system for CT (NCICT, Version 3) considering a low-dose CT protocol (CTDIvol: 8.97 mGy). Main Results: The majority of the fetal organ/tissue doses from the proton PBS CSI treatment fell within a range of 3 to 6 mGy. The fetal organ/tissue doses for the 38-week phantom showed the largest variation with the doses ranging from 2.9 mGy (adrenals) to 8.2 mGy (eye lenses) while the smallest variation ranging from 3.2 mGy (oesophagus) to 4.4 mGy (brain) was observed for the doses for the 20-week phantom. The fetal whole-body dose ranged from 3.7 mGy (25 weeks) to 5.8 mGy (8 weeks). Most of the fetal doses from the planning CT scan fell within a range of 7 to 13 mGy, approximately 2-to-9 times lower than the fetal dose equivalents of the proton PBS CSI treatment (assuming a quality factor of 7). Significance: The fetal organ/tissue doses observed in the present work will be useful for one of the first clinically informative predictions on the magnitude of fetal dose during proton PBS CSI during pregnancy.


2022 ◽  
Author(s):  
Stine Nyby ◽  
Signe Hertz Hansen ◽  
Sophie Yammeni ◽  
Agnieszka Monika Delekta ◽  
Gintare Naujokaite ◽  
...  

Abstract Purpose: Breast cancer patients scheduled for postoperative radiotherapy undergo radiotherapy-planning computed tomography (CT), and incidental findings (IFs) may appear. This study investigated the interobserver variability between radiologists and oncologists when assessing IFs on radiotherapy-planning CT scans in breast cancer patients prior to adjuvant radiotherapy. Methods: We included 383 breast cancer patients who underwent planning CT at the Aalborg University Hospital between February 1, 2017 and February 28, 2018. IFs noted by the oncologists were identified from medical records. Two specialized radiologists reviewed the scans and described their IFs. IFs were classified as benign or potential malignant lesions. Cohen’s kappa statistic was used to measure interobserver agreement.Results: A total of 513 IFs were registered. The radiologists registered 433 findings, and the oncologists noted 80 (1.1 and 0.2 IFs per patient, respectively). Most potential malignant IFs were found in the liver, lungs, bones, and lymph nodes. The radiologists and oncologists detected potential malignant lesions in 94 (25%) and 34 (9%) patients, respectively. The oncologists’ sensitivity for detecting IFs in the liver and lungs were 29% and 20%, respectively. The agreements on IFs in the liver and lungs were fair (Cohen’s kappa values of 0.33 and 0.28, respectively).Conclusion: Radiologists reported a significantly higher frequency of IFs and potential malignant lesions than oncologists. Additionally, the oncologists had a low sensitivity when reporting IFs in both the liver and lungs. These results emphasize the need for specialized radiologists to scrutinize planning CT scans of breast cancer patients to ensure the intention to treat.


2022 ◽  
Vol 71 ◽  
pp. 103074
Author(s):  
João Otàvio Bandeira Diniz ◽  
Jonnison Lima Ferreira ◽  
Pedro Henrique Bandeira Diniz ◽  
Aristófanes Corrêa Silva ◽  
Anselmo Cardoso Paiva

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Katrina Woodford ◽  
Vanessa Panettieri ◽  
Jeremy D. Ruben ◽  
Sidney Davis ◽  
Trieumy Tran Le ◽  
...  

Abstract Background To determine the optimal volume of barium for oesophageal localisation on cone-beam CT (CBCT) for locally-advanced non-small cell lung cancers (NSCLC) and quantify the interfraction oesophageal movement relative to tumour. Methods Twenty NSCLC patients with mediastinal and/or hilar disease receiving radical radiotherapy were recruited. The first five patients received 25 ml of barium prior to their planning CT and alternate CBCTs during treatment. Subsequent five patient cohorts, received 15 ml, 10 ml and 5 ml. Six observers contoured the oesophagus on each of the 107 datasets and consensus contours were created. Overall 642 observer contours were generated and interobserver contouring reproducibility was assessed. The kappa statistic, dice coefficient and Hausdorff Distance (HD) were used to compare barium-enhanced CBCTs and non-enhanced CBCTs. Oesophageal displacement was assessed using the HD between consensus contours of barium-enhanced CBCTs and planning CTs. Results Interobserver contouring reproducibility was significantly improved in barium-enhanced CBCTs compared to non-contrast CBCTs with minimal difference between barium dose levels. Only 10 mL produced a significantly higher kappa (0.814, p = 0.008) and dice (0.895, p = 0.001). The poorer the reproducibility without barium, the greater the improvement barium provided. The median interfraction HD between consensus contours was 4 mm, with 95% of the oesophageal displacement within 15 mm. Conclusions 10 mL of barium significantly improves oesophageal localisation on CBCT with minimal image artifact. The oesophagus moves substantially and unpredictably over a course of treatment, requiring close daily monitoring in the context of hypofractionation.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Shuxue Zhao ◽  
Xianfa Lu ◽  
Jiasen Zou ◽  
Zhouying Xu ◽  
Siyu Wei ◽  
...  

Objective. To investigate the influence of cold weather on setup errors of patients with chest and pelvic disease in radiotherapy. Methods. The image-guided data of the patients were collected from the Radiotherapy Center of Cancer Hospital Affiliated to Guangxi Medical University from October 2020 to February 2021. During this period, the cold weather days were December 15, 16, and 17, 2020, and January 7 and 8, 2021. For body fixation in radiotherapy, an integrated plate and a thermoplastic mold were employed in 18 patients with chest disease, while an integrated plate and a vacuum pad were applied in 19 patients with pelvic disease. All patients underwent cone beam computed tomography (CBCT) scans in the first five treatments and once a week thereafter. The obtained data were registered to the planning CT image to get the setup errors of the patient in the translational direction including X, Y, and Z axes and rotational direction including RX, RY, and RZ. Then, the Mann–Whitney U test was performed. The expansion boundary values of the chest and pelvis were calculated according to the formula M PTV = 2.5 ∑ + 0.7 δ . Results. A total of 286 eligible results of CBCT scans were collected. There were 138 chest CBCT scans, including 26 taken in cold weather and 112 in usual weather, and 148 pelvic CBCT scans, including 33 taken in cold weather and 115 in usual weather. The X-, Y-, and Z-axis translational setup errors of patients with chest disease in the cold weather group were 0.16 (0.06, 0.32) cm, 0.25 (0.17, 0.52) cm, and 0.35 (0.21, 0.47) cm, respectively, and those in the usual weather group were 0.14 (0.08, 0.29) cm, 0.23 (0.13, 0.37) cm, and 0.18 (0.1, 0.35) cm, respectively. The results indicated that there was a statistical difference in the Z-axis translational error between the cold weather group and the usual weather group (U = 935.5; p = 0.005 < 0.05 ), while there was no statistical difference in the rotational error between the two groups. The external boundary values of X, Y, and Z axes in the cold weather group were 0.57 cm, 0.92 cm, and 0.99 cm, respectively, and those in the usual weather group were 0.57 cm, 0.78 cm, and 0.68 cm, respectively. There was no significant difference in the translational and rotational errors of patients with pelvic disease between the cold weather group and the usual weather group ( p < 0.05 ). The external boundary values of X, Y, and Z axes were 0.63 cm, 0.79 cm, and 0.68 cm in the cold weather group and 0.61 cm, 0.79 cm, and 0.61 cm in the usual weather group, respectively. Conclusion. The setup error of patients undergoing radiotherapy with their bodies fixed by an integrated plate and a thermoplastic mold was greater in cold weather than in usual weather, especially in the ventrodorsal direction.


2021 ◽  
Vol 11 ◽  
Author(s):  
Zhenhui Dai ◽  
Yiwen Zhang ◽  
Lin Zhu ◽  
Junwen Tan ◽  
Geng Yang ◽  
...  

PurposeWe developed a deep learning model to achieve automatic multitarget delineation on planning CT (pCT) and synthetic CT (sCT) images generated from cone-beam CT (CBCT) images. The geometric and dosimetric impact of the model was evaluated for breast cancer adaptive radiation therapy.MethodsWe retrospectively analyzed 1,127 patients treated with radiotherapy after breast-conserving surgery from two medical institutions. The CBCT images for patient setup acquired utilizing breath-hold guided by optical surface monitoring system were used to generate sCT with a generative adversarial network. Organs at risk (OARs), clinical target volume (CTV), and tumor bed (TB) were delineated automatically with a 3D U-Net model on pCT and sCT images. The geometric accuracy of the model was evaluated with metrics, including Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD95). Dosimetric evaluation was performed by quick dose recalculation on sCT images relying on gamma analysis and dose-volume histogram (DVH) parameters. The relationship between ΔD95, ΔV95 and DSC-CTV was assessed to quantify the clinical impact of the geometric changes of CTV.ResultsThe ranges of DSC and HD95 were 0.73–0.97 and 2.22–9.36 mm for pCT, 0.63–0.95 and 2.30–19.57 mm for sCT from institution A, 0.70–0.97 and 2.10–11.43 mm for pCT from institution B, respectively. The quality of sCT was excellent with an average mean absolute error (MAE) of 71.58 ± 8.78 HU. The mean gamma pass rate (3%/3 mm criterion) was 91.46 ± 4.63%. DSC-CTV down to 0.65 accounted for a variation of more than 6% of V95 and 3 Gy of D95. DSC-CTV up to 0.80 accounted for a variation of less than 4% of V95 and 2 Gy of D95. The mean ΔD90/ΔD95 of CTV and TB were less than 2Gy/4Gy, 4Gy/5Gy for all the patients. The cardiac dose difference in left breast cancer cases was larger than that in right breast cancer cases.ConclusionsThe accurate multitarget delineation is achievable on pCT and sCT via deep learning. The results show that dose distribution needs to be considered to evaluate the clinical impact of geometric variations during breast cancer radiotherapy.


Tomography ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. 747-751
Author(s):  
Robert Devita ◽  
Kaushik Chagarlamudi ◽  
Jared Durieux ◽  
David Jordan ◽  
Brian Nguyen ◽  
...  

The purpose of this study is to evaluate the impact of eliminating a preprocedural planning computed tomography during CT-guided bone marrow biopsy on the technical aspects of the procedure, including patient dose, sample quality, procedure time, and CT fluoroscopy usage. Retrospective analysis of 109 patients between 1 June 2018 and 1 January 2021 was performed. Patients were grouped based on whether they received a planning CT scan. Relative radiation exposure was measured using dose-length product (DLP). Secondary metrics included number of CT fluoroscopic acquisitions until target localization, total number of CT fluoroscopic acquisitions, biopsy diagnostic yield, and procedure time. A total of 43 bone marrow biopsies with planning CT scans (Group 1) and 66 bone marrow biopsies without planning CT scans (Group 2) were performed. The average total DLP for Group 1 and Group 2 was 268.73 mGy*cm and 50.92 mGy*cm, respectively. The mean radiation dose reduction between the groups was 81% (p < 0.0001). Significantly more CT fluoroscopy acquisitions were needed for needle localization in Group 2 than Group 1 (p < 0.0001). Total number of CT fluoroscopy acquisitions was four for Group 1 and eight for Group 2 (p = 0.0002). There was no significant difference between the groups in procedure time or diagnostic yield. Patients without a planning CT scan received more fluoroscopic CT acquisitions but overall were exposed to significantly less radiation without an increase in procedure time.


2021 ◽  
Vol 11 ◽  
Author(s):  
Bin Feng ◽  
Lei Yu ◽  
Enwei Mo ◽  
Liyuan Chen ◽  
Jun Zhao ◽  
...  

PurposeThe difference in anatomical structure and positioning between planning and treatment may lead to bias in electronic portal image device (EPID)-based in vivo dosimetry calculations. The purpose of this study was to use daily CT instead of planning CT as a reference for EPID-based in vivo dosimetry calculations and to analyze the necessity of using daily CT for EPID-based in vivo dosimetry calculations in terms of patient quality assurance.Materials and MethodsTwenty patients were enrolled in this study. The study design included eight different sites (the cervical, nasopharyngeal, and oral cavities, rectum, prostate, bladder, lung, and esophagus). All treatments were delivered with a CT-linac 506c (UIH, Shanghai) using 6 MV photon beams. This machine is equipped with diagnosis-level fan-beam CT and an amorphous silicon EPID XRD1642 (Varex Imaging Corporation, UT, USA). A Monte Carlo algorithm was developed to calculate the transmit EPID image. A pretreatment measurement was performed to assess system accuracy by delivering based on a homogeneous phantom (RW3 slab, PTW, Freiburg). During treatment, each patient underwent CT scanning before delivery either once or twice for a total of 268 fractions obtained daily CT images. Patients may have had a position correction that followed our image-guided radiation therapy (IGRT) procedure. Meanwhile, transmit EPID images were acquired for each field during delivery. After treatment, all patient CTs were reviewed to ensure that there was no large anatomical change between planning and treatment. The reference of transmit EPID images was calculated based on both planning and daily CTs, and the IGRT correction was corrected for the EPID calculation. The gamma passing rate (3 mm 3%, 2 mm 3%, and 2 mm 2%) was calculated and compared between the planning CT and daily CT. Mechanical errors [ ± 1 mm, ± 2 mm, ± 5 mm multileaf collimator (MLC) systematic shift and 3%, 5% monitor unit (MU) scaling] were also introduced in this study for comparing detectability between both types of CT.ResultThe average (standard deviation) gamma passing rate (3 mm 3%, 2 mm 3%, and 2 mm 2%) in the RW3 slab phantom was 99.6% ± 1.0%, 98.9% ± 2.1%, and 97.2% ± 3.9%. For patient measurement, the average (standard deviation) gamma passing rates were 87.8% ± 14.0%, 82.2% ± 16.9%, and 74.2% ± 18.9% for using planning CTs as reference and 93.6% ± 8.2%, 89.7% ± 11.0%, and 82.8% ± 14.7% for using daily CTs as reference. There were significant differences between the planning CT and daily CT results. All p-values (Mann–Whitney test) were less than 0.001. In terms of error simulation, nonparametric test shows that there were significant differences between practical daily results and error simulation results (p &lt; 0.001). The receiver operating characteristic (ROC) analysis indicated that the detectability of mechanical delivery error using daily CT was better than that of planning CT. AUCDaily CT = 0.63–0.96 and AUCPlanning CT = 0.49–0.93 in MLC systematic shift and AUCDaily CT = 0.56–0.82 and AUCPlanning CT = 0.45–0.73 in MU scaling.ConclusionThis study shows the feasibility and effectiveness of using two-dimensional (2D) EPID portal image and daily CT-based in vivo dosimetry for intensity-modulated radiation therapy (IMRT) verification during treatment. The daily CT-based in vivo dosimetry has better sensitivity and specificity to identify the variation of IMRT in MLC-related and dose-related errors than planning CT-based.


2021 ◽  
Vol 23 (Supplement_6) ◽  
pp. vi42-vi42
Author(s):  
Drishti Panse ◽  
Aubrey Rogers ◽  
Edward Farhangi ◽  
Maria Péris-Celda ◽  
Khaled Adil

Abstract BACKGROUND The incidence of brain metastasis is approximately 200,000 worldwide annually. Stereotactic radiation therapy of post-operative cavity reduces local recurrence. Surgical cavity size changes significantly with 96.5% demonstrating volumetric change during post-operative period. We sought to define the optimal time interval that preserved the volumetric dimensions between the post-surgical MRI and the CT simulation used for stereotactic radiosurgery planning. METHODS Seven patients with brain metastasis that underwent surgical resection and stereotactic radiation treatment at Albany Medical Center from February 2019 to April 2020 were included in the study. A total of 8 target lesions were included. Brain lab planning system was used for contouring the target volume. A postoperative MRI within 24-48 hours after surgery was obtained. 3 patients required an additional interim MRI 16-50 days after surgery. The planning CT simulation was performed 2 days prior and up to 15 days after the post-operative/interim MRI and target volumes were compared. RESULTS The average volume of the post-surgical cavity contoured by the neurosurgeons on the post-operative/interim MRI was 15.96 cc (± 7.79 cc, range of 6.54 -24.9 cc). The average volume of the post-surgical cavity contoured by the radiation oncologists on the planning CT was 15.71 (± 7.49 cc, range of 6.53 -24.31 cc). There was no noticeable change in volume size between post-operative/interim MRI and planning CT up to the period of 15 days. LIMITATION This was a retrospective pilot study with a small sample size and patients recruited from a single center. CONCLUSION There is no change in size of the cavity volume for up to 15 days between post-operative/interim MRI and planning CT. This knowledge will help understand the optimal time interval between post-operative MRI and CT simulation for the stereotactic radiation therapy planning.


2021 ◽  
Vol 6 (4) ◽  
pp. 407-415
Author(s):  
Ragavendra D Sagar ◽  
Irappa Madabhavi ◽  
Swaroop Revannasiddaiah

Aims & Objective: Hematological toxicity is common in patients with cervical cancer treated with concurrent chemo radiotherapy (CT-RT), so the purpose is to assess this hematological toxicity and correlate the toxicity with the dose and volume of bone marrow included in the field of radiation. Materials & Methods: Twenty five patients with histologically proven cervical cancer attending to our Cancer centre from July 2018-August 2019 were the subjects of this study. Patients were treated on 6 MV linear accelerator with a radical intent with concurrent chemotherapy using cisplatin 50 mg weekly. The planning CT was done for all the patients before the treatment and contouring of the pelvic bone marrow apart from other organs at risk was done. Hematological toxicity was assessed using RTOG common toxicity criteria weekly during and at 2 weeks after the completion of the treatment. Results: A total of 25 patients on CT-RT treatment were assessed. Sixteen patients were in locally advanced stage. The variation in HB, TLC, Platelets, and ANC counts from the baseline to 2 weeks after chemo radiotherapy were assessed. Grade II anemia was observed in 12 and Grade III in 2 patients. There were no toxicity as far as WBC and platelets were considered. There was also no correlation between the volume of bone marrow included in the field of irradiation and appearance of anemia. Conclusion: CT-RT for cervical cancer is safe and is associated with minimal hematological toxicity in the form of anemia. The toxicity is same for different volumes of bone marrow included in the field of irradiation with both 3DCRT as well as IMRT technique. The toxicity observed is probably contributed by Cisplatin.


Sign in / Sign up

Export Citation Format

Share Document