scholarly journals Geophysical Investigation of Building Foundation in Part of Ilorin, North Central Nigeria Using Electrical Resistivity Method

2019 ◽  
Vol 1299 ◽  
pp. 012064
Author(s):  
G. B. Egbeyale ◽  
T. T. Ogunseye ◽  
K.O. Ozegin
2020 ◽  
Vol 4 (2) ◽  
pp. 65-69
Author(s):  
Obaro R.I ◽  
Agbalajobi S.A ◽  
Adio O

Geophysical investigation using electrical sounding technique was carried out in Tanke community Ilorin, in order to characterize or explore ground water potential. The top soil resistivity values vary from 68.1Ωm to 65.1Ωm and thickness varying between 1.7m to 9.9m. The second layer resistivity values varies from 32.9Ωm to 651.1Ωm and the thickness vary from 2.9m to 12.7m.The third layer is the weathered basement with resistivity and thickness values varying between 22.6Ωm to 9562.6Ωm and 7.8m to 51.1m.The fourth layer is the partly weathered and fractured basement with resistivity and thickness values varying between 101Ωm to 2100Ωm and 80.1m to 124m while the fifth layer is apparently fresh basement whose resistivity values vary from 154.9Ωm to 7130Ωm with an infinite depth. The study further reveal VES 3, 4, and 5 as productive fractures within the weathered basement while other VES points are not productive.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Olaseeni Olayiwola ◽  
Fagbemigun Tokunbo ◽  
Ojo Bosede ◽  
Amosun Joel ◽  
Oyebamiji Ajibola

Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.


2016 ◽  
Vol 33 (3) ◽  
Author(s):  
Eduardo M.S. Amarante ◽  
Olivar A.L. de Lima ◽  
Susana S. Cavalcanti

ABSTRACT. To investigate the subsurface geological and hydrological conditions around the area of the Alagoinhas county cemetery – Bahia State, Brazil, 38 vertical electrical soundings using Schlumberger electrode array were performed to a maximum AB/2 spacing... RESUMO. Para investigar as condições geológicas e hidrológicas da subsuperfície na área do entorno do Cemitério Municipal de Alagoinhas, Bahia, foram realizadas 38 sondagens elétricas verticais centradas em pontos acessíveis da área. As sondagens foram...


Sign in / Sign up

Export Citation Format

Share Document