scholarly journals Geophysical Assessment of Groundwater Vulnerability to Diesel Contamination at a Telecommunication Mast in Adebayo Area, Ado-Ekiti, Southwestern Nigeria

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Olaseeni Olayiwola ◽  
Fagbemigun Tokunbo ◽  
Ojo Bosede ◽  
Amosun Joel ◽  
Oyebamiji Ajibola

Abstract An appraisal of the groundwater vulnerability to contamination risk at Adebayo in Ado-Ekiti, Southwestern Nigeria, was carried out using the electrical resistivity method of geophysical prospecting. Two traverses of length 100 m each were established for both vertical electrical sounding (VES) and dipole-dipole. Six (6) Vertical Electrical Sounding (VES) and 2-D dipole-dipole profiling techniques of the electrical resistivity method were adopted for the geophysical investigation. The results show variations in resistivity values, depicting four to five geologic layers: the topsoil, laterite, weathered layer, fractured, and the fresh basement. It was observed from the correlation of the geoelectric section and 2-D resistivity image along traverse 1 (TR1) that the groundwater in the study area flows towards the southwestern part, and the fractured basement serves as a migration pathway to the diesel oil in the same direction as groundwater flow. The fractured basement (Well 2) with no lateritic cover has higher resistivity values compare to the fracture zone that was found directly under the mast which was overlain by the laterite. Comparing the resistivity values of Well 1 and 2, Well 2 that was drilled into the fractured basement has more traces of the contaminant than Well 1.

2020 ◽  
Vol 4 (2) ◽  
pp. 65-69
Author(s):  
Obaro R.I ◽  
Agbalajobi S.A ◽  
Adio O

Geophysical investigation using electrical sounding technique was carried out in Tanke community Ilorin, in order to characterize or explore ground water potential. The top soil resistivity values vary from 68.1Ωm to 65.1Ωm and thickness varying between 1.7m to 9.9m. The second layer resistivity values varies from 32.9Ωm to 651.1Ωm and the thickness vary from 2.9m to 12.7m.The third layer is the weathered basement with resistivity and thickness values varying between 22.6Ωm to 9562.6Ωm and 7.8m to 51.1m.The fourth layer is the partly weathered and fractured basement with resistivity and thickness values varying between 101Ωm to 2100Ωm and 80.1m to 124m while the fifth layer is apparently fresh basement whose resistivity values vary from 154.9Ωm to 7130Ωm with an infinite depth. The study further reveal VES 3, 4, and 5 as productive fractures within the weathered basement while other VES points are not productive.


2021 ◽  
Vol 5 (1) ◽  
pp. 18
Author(s):  
Matthew Tersoo Tsepav ◽  
Aliyu Yahaya Badeggi ◽  
Obaje Nuhu George ◽  
Usman Yusuf Tanko ◽  
Ibrahim Samuel Ibbi

<p>Electrical resistivity method employing the Schlumberger array was used to occupy forty four (44) vertical electrical sounding points in Lapai town with the aim of determining the depth to aquifers, aquifer thicknesses and aquifer protective capacity. The G41 Geotron resistivity meter was used in obtaining the apparent resistivity data which was processed using Interpex 1XD resistivity interpretation software. The results revealed four lithologic sections which include top lateritic soil, sandy clay, fractured basement and fresh basement. Both confined and unconfined aquifers were identified within the area, with four classes of aquifer proactive capacities as high, moderate, weak and poor. While the aquifer at VES 20 was highly protected, twenty other aquifers were moderately protected, eight others had weak protection and fifteen aquifers were poorly protected. The aquifers were generally of good thicknesses and at varying reasonable depths, making them good reservoirs of water in appreciable quantity. The average aquifer thickness was estimated to be 48.36m while the average depth to aquifers was estimated to be 56.68m.</p>


Author(s):  
K. O. Ozegin

The ultimate aim of the electrical resistivity survey is to determine the resistivity distribution with depth on the basis of surface measurements of the apparent resistivity and to interpret it in terms of geology. Marble deposit was investigated with the application of electrical resistivity method using Vertical Electrical Sounding (VES) technique with the aim of characterising this deposit in parts of Okpella. Six (6) VES were acquired using the Schlumberger array for data acquisition with current electrode spacing varying from 1.0 to 150.0 m. The VES data obtained were interpreted using ipi2win Software. The results showed three layers indicating subsurface geologic sequence probed 26.4 m and beyond with clay/clayey sand (23.3 – 219.1 Ωm), sand (423 - 2040 Ωm) and marble (12661 - 404498 Ωm). The occurrence of marble deposit was revealed at VES points at 1, 2 and 5 in the studied area.  This study concluded that the study area had occurrence of the marble deposits, which would be of economic importance, if exploited.


2020 ◽  
Vol 8 (11) ◽  
pp. 175-184
Author(s):  
Saleh Mustapha Babagana ◽  
Satendra Sharma

Electrical resistivity method using vertical electrical sounding (VES) technique and Schlumberger array was employed with the aim of delineating limits and types of aquifer system(s), and stratigraphic composition of the Demsa area, a confluence of Benue River in Northeast Nigeria. The result revealed that the hydrogeology of the area may be controlled by fractures (secondary porosity) developed in sedimentary units. Two aquifers, namely the upper alluvial aquifer and the confined deeper aquifer systems exist in the study area. The two aquifers occur at depths of 20.5 – 41 m, and 43.8 – 78.9 m respectively, and are separated by a thin layer of poorly permeable clays and silts, ranged between 1.1 – 5.3 m in thickness. The lateral extent of the aquifer systems extend almost evenly across the area. The aquifers’ thickness tends to decrease with increase in distance of VES station from the Benue River which suggested that the aquifer systems are probably recharged by direct escapement of the Benue River.


Application of geophysical investigation has been carried out using Vertical Electrical Sounding (VES) at the proposed site in wadi Ma’doo, Shabwah Governorate, Yemen to determine the geophysical parameters that can be used to evaluate the subsurface geological layering characteristics of the selection proposed site for dam construction. The Schlumberger array was used for the data acquisition. One-dimensional numerical inversion of individual DC resistivity was used to enhance the processing of the results for better achievement of the aim of the study. Model obtained from the 2D inversion of each VES were used for construction of geoelectric section which exhibit the main geoelectric characteristics of the geological units present in the site. The interpretation of the field data was carried out using the IP12WIN software, which converts the apparent resistivity as a function of electrode spacing to the true resistivity as a function of depth in two dimensions. The interpretation results showed that the geoelectric section consists of three layers namely: boulders and gravels, sandy to pebbly and hard limestone. The layer resistivities and thicknesses range from 18.17 to 746.20 Ω.m/0.20 to 1.084 m, 53 to 60 Ω.m/ 0.20 to 3.059 m and 455 to 1890 Ω.m, respectively. The investigation revealed that the limestone rocks is suitable for shallow foundation for proposed dam engineering structures.