scholarly journals Time Resolution Simulation Measurement for the Configuration Plastic Scintillator Material+SiPM and its Application to Medical Physics

2020 ◽  
Vol 1540 ◽  
pp. 012031
Author(s):  
C H Zepeda
Author(s):  
C. H. Zepeda Fernández ◽  
Hernández Aguilar Javier Efrén ◽  
E. Moreno-Barbosa

The high time resolution detectors are relevant in those experiments or simulations were the particles to detect, have a very short time of flight (TOF), and due this it´s required that the detections times are ranged between ns. & ps.Using Geant4 software, it was made thirty simulations of coupled detectors to plastic scintillators with two silicon photomultipliers (SiPMs) located on the scintillator’s central sides. To characterize the time resolution, it was required to quantify the optical photons that reach the Score in a certain time, which are generated by muons on the surface of the plastic scintillator. Different configurations of muon beams were simulated at energy of 1 GeV, to interact with the configuration of the scintillator material of its corresponding arrangement. The simulations were made varying three parameters: the scintillator material “BC404 & BC422”, its size, and the location of the radiation source. Fifteen simulations correspond to BC404 material & fifteen simulations to BC422 material respectively. The first five simulations consisted in varying the scintillator’s volumetric size and collocate the muons beam guided randomly distributed over it, the next five simulations differentiate from setting up a directly centered beam, and the last five simulations for guide the beam on the left lower corner of each scintillator.The best time resolution achieved was σ= 8.67 +/− 0.26 ps., reported by the detector with BC422 scintillator material which has a volume of 20x20x3 mm3.


Author(s):  
Jiaxing Li ◽  
Denggao Zhang ◽  
Pingping Liu

We present here an ellipsoidal timing detector in Radioactive Ion Beam Line in Lanzhou (RIBLL). The photons induced by radioactive beam ions passing through a thin plastic-scintillator foil BC422, emit from the foil center corresponding to one focal point of an aluminum ellipsoidal mirror and are reflected to another focus point at which the cathode of a photomultiplier tube locates. A time resolution of about 115ps is achieved for 12N and the counting rate up to 108 pps is allowed. The simulation was carried out using GEANT4 Monte Carlo toolkit. The photons total collection efficiency following projectile from different position, photon collection efficiency and time resolution of photon to photocathode of 3 different cases were calculated. Also the main factors influencing the detector’s time resolution and some proposals are given.


2008 ◽  
Vol 276 (3) ◽  
pp. 743-748 ◽  
Author(s):  
J. Ely ◽  
K. Anderson ◽  
D. Bates ◽  
R. Kouzes ◽  
C. Lo Presti ◽  
...  

2022 ◽  
Vol 17 (01) ◽  
pp. P01016
Author(s):  
A. Korzenev ◽  
F. Barao ◽  
S. Bordoni ◽  
D. Breton ◽  
F. Cadoux ◽  
...  

Abstract ND280 is a near detector of the T2K experiment which is located in the J-PARC accelerator complex in Japan. After a decade of fruitful data-taking, ND280 is scheduled for upgrade. The time-of-flight (ToF) detector, which is described in this article, is one of three new detectors that will be installed in the basket of ND280. The ToF detector has a modular structure. Each module represents an array of 20 plastic scintillator bars which are stacked in a plane of 2.4 × 2.2 m2 area. Six modules of similar construction will be assembled in a cube, thus providing an almost 4π enclosure for an active neutrino target and two TPCs. The light emitted by scintillator is absorbed by arrays of large-area silicon photo-multipliers (SiPMs) which are attached to both ends of every bar. The readout of SiPMs, shaping and analog sum of individual SiPM signals within the array are performed by a discrete circuit amplifier. An average time resolution of about 0.14 ns is achieved for a single bar when measured with cosmic muons. The detector will be installed in the basket of ND280, where it will be used to veto particle originating outside the neutrino target, improve the particle identification and provide a cosmic trigger for calibration of detectors which are enclosed inside it.


2016 ◽  
Vol 61 (5) ◽  
pp. 2025-2047 ◽  
Author(s):  
P Moskal ◽  
O Rundel ◽  
D Alfs ◽  
T Bednarski ◽  
P Białas ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document