scholarly journals Analysis on the Problem of Blocking of the Storage Pump Caused by Peak Load Regulation of the Unit

Author(s):  
Ke Liu ◽  
Haichao Wang ◽  
Jinglong Liu ◽  
Fuxing Cui ◽  
Chuanjun Duan ◽  
...  
Keyword(s):  
Author(s):  
Yifan Wu ◽  
Wei Li ◽  
Deren Sheng ◽  
Jianhong Chen ◽  
Zitao Yu

Clean energy is now developing rapidly, especially in the United States, China, the Britain and the European Union. To ensure the stability of power production and consumption, and to give higher priority to clean energy, it is essential for large power plants to implement peak shaving operation, which means that even the 1000 MW steam turbines in large plants will undertake peak shaving tasks for a long period of time. However, with the peak load regulation, the steam turbines operating in low capacity may be much more likely to cause faults. In this paper, aiming at peak load shaving, a fault diagnosis method of steam turbine vibration has been presented. The major models, namely hierarchy-KNN model on the basis of improved principal component analysis (Improved PCA-HKNN) has been discussed in detail. Additionally, a new fault diagnosis method has been proposed. By applying the PCA improved by information entropy, the vibration and thermal original data are decomposed and classified into a finite number of characteristic parameters and factor matrices. For the peak shaving power plants, the peak load shaving state involving their methods of operation and results of vibration would be elaborated further. Combined with the data and the operation state, the HKNN model is established to carry out the fault diagnosis. Finally, the efficiency and reliability of the improved PCA-HKNN model is discussed. It’s indicated that compared with the traditional method, especially handling the large data, this model enhances the convergence speed and the anti-interference ability of the neural network, reduces the training time and diagnosis time by more than 50%, improving the reliability of the diagnosis from 76% to 97%.


2017 ◽  
Vol 09 (04) ◽  
pp. 452-463
Author(s):  
Cong Liu ◽  
Deyue Men ◽  
Dan Xu ◽  
Qiang Ding ◽  
Guodong Huang ◽  
...  

2020 ◽  
Vol 143 ◽  
pp. 02047
Author(s):  
Shufang Tang ◽  
Guoan Tang ◽  
Xiaohong He ◽  
Lijun Zheng ◽  
Cong Yu ◽  
...  

This paper introduces the retrofit scheme of the New Condensing Extraction Backpressure heating technology, and the technology is recommend for use by comparing and analysing the combined heat and power system based on a 330MW unit retrofit. After improvement, the heating capacity has been Obvious improved, the generation power has been greatly reduced and the capacity of peak load regulation has been significantly improved, which can not only realize the thermoelectric decoupling, but also obtain the remarkable economic benefit.


2018 ◽  
Vol 152 ◽  
pp. 227-232 ◽  
Author(s):  
Feixiang Peng ◽  
Wei Zhou ◽  
Xin Sui ◽  
Shubo Hu ◽  
Hui Sun ◽  
...  

2014 ◽  
Vol 986-987 ◽  
pp. 465-469 ◽  
Author(s):  
Gang Wang ◽  
Xiao Dong Ma ◽  
Chao Wang ◽  
Peng Ye

Base on Nuclear Power Plant (NPP) participating in peak load regulation of power grid, this paper studies the operation mode of hydropower, thermal power and NPP in Combined Peak Load Regulation. The optimization model for Peaking depth of NPP was set up. The case based on actual power grid were calculated and analyzed, results of the research show that in combined peak load regulation of hydropower, thermal power and NPP, a reasonable peaking depth of NPP will effectively alleviate the peaking pressure of power grid, avoid start-stop of thermal power and abandoned water of hydropower, while ensuring the hydroelectric generating capacity in the low load periods, and ensure thermal power output smooth, it further reduce the operating costs, verify the effectiveness of the model.


2013 ◽  
Vol 416-417 ◽  
pp. 2110-2113
Author(s):  
Xing Liu

This paper, focusing on the practical moving condition of the thermal power plants, studied in detail that how to did the curve fitting according to the units data collected from Tianjin Dagang Power Plant; studied the each fuel loss in the process of start-stop the units and their calculation methods; and put forward that fuel consumption and life expenditure while starting and stopping the units should be considered when using peak-load regulation; worked out the GA program and proved GAs accuracy and superiority through the calculation examples, and showed that GA had great practical and research meaning.


Sign in / Sign up

Export Citation Format

Share Document