scholarly journals Development and Validation of a RP-HPLC Method for the Estimation of Netilmicin Sulfate and its Related Substances using Charged Aerosol Detection

2010 ◽  
Vol 48 (7) ◽  
pp. 607-612 ◽  
Author(s):  
A. Joseph ◽  
S. Patel ◽  
A. Rustum
Author(s):  
O. S. S. Chandana ◽  
D. Sathis Kumar ◽  
R. Ravichandra Babu

Objective: Our main objective is to develop an accurate and precise RP-HPLC method for the determination of Eprosartan Mesylate and its impurities. Methods: A Develosil ODS UG-5; (150 × 4.6) mm; 5 µm column was used for the Separation of drugs by a mobile phase consisting of Buffer and Acetonitrile mixture in the gradient proportion. The flow rate maintained was 0.8 ml/min and the wavelength used for detection was 235 nm.Results: The linearity was observed in the range of 0.025-50µg/ml of spiked impurities in Eprosartan Mesylate, impurity 1 and impurity 2 with a correlation coefficient of 0.99927, 0.99910 and 0.99934 respectively. The mean percentage recoveries for LOQ, 50%, 80%, 100%, 150% and 200% accuracy were found to be 101.5±1.51, 107.0±1.7, 104.6±0.4, 102.8±0.36, 101.7±0.26 and 101.3±0.15 respectively for impurities in Eprosartan Mesylate, impurity 1 and impurity 2. Linearity, accuracy, precision and robustness parameters for the suggested method were estimated for validation.Conclusion: The developed method is uncomplicated, accurate, sensitive and precise for the determination of related substances in the Eprosartan Mesylate. The satisfying % recoveries and low % RSD Values confirmed the suitability of the developed method for the usual analysis of Eprosartan mesylate in pharmaceuticals.


Author(s):  
SRINIVAS LINGABATHULA ◽  
NEELU JAIN

Objective: The current investigation was pointed at developing and progressively validating novel, simple, responsive and stable RP-HPLC method for the measurement of active pharmaceutical ingredients of Favipiravir and Peramivir and their related substances. Methods: A simple, selective, validated and well-defined stability that shows gradient RP-HPLC methodology for the quantitative determination of Favipiravir and Peramivir. The chromatographic strategy utilized Inertsil ODS column of dimensions 250x4.6 mm, 5 micron, using isocratic elution with a mobile phase of acetonitrile and 0.1 percent orthophosphoric acid (70:30). A flow rate of 1 ml/min and a detector wavelength of 260 nm utilizing the PDA detector was given in the instrumental settings. Using the impurity-spiked solution, the chromatographic approach was streamlined. Results: Validation of the proposed method was carried out according to an international conference on harmonization (ICH) guidelines. LOD and LOQ for the two active ingredients and their impurities were established with respect to test concentration. The calibration charts plotted were linear with a regression coefficient of R2>0.999, which means the linearity was within the limit. Recovery, specificity, linearity, accuracy, robustness, ruggedness was determined as a part of method validation and the results were found to be within the acceptable range. Conclusion: The proposed method to be fast, simple, feasible and affordable in RS condition. During stability tests, it can be used for routine analysis of production samples and to verify the quality of drug samples during stability studies.


Author(s):  
M. Zeba Baktiyar ◽  
B. Mohammed Ishaq ◽  
Siva Sanker Reddy L ◽  
Sreenivasulu M.

A simple, precise and reproducible RP-HPLC method was developed for the estimation of related substances in tilorone dihydrochloride. Quantification was performed using a Zorbax SB-phenyl column (150 × 4.6mm, 5µ) with mobile phase A: 20mM potassium dihydro phosphate + 2ml of triethylamine, pH 2.30 and mobile phase B: acetonitrile, methanol and water 60: 20: 20% v/v. A gradient program was followed with a run time of 55 minutes at a flow rate of 1.0 ml/min. The column temperature was maintained at 40°C, the injection volume was 10 µl and the detection was performed at 269nm using a PDA detector. The retention time of Tilorone dihydrochloride was found to be 10.36 minutes. The proposed method has been validated according to the ICH guidelines for Linearity, Precision, Accuracy, LOD, and LOQ. The method was linear from 0.157 - 3.934μg/ml for standard, 0.153-3.820μg/ml and 0.166 - 4.140μg/ml for impurities, TLHC01 and TLHC02 respectively. The impurities TLHC01 and TLHC02 have been mapped in all stress conditions. The LOD and LOQ of TLHC01 were found at 1.757μg/ml and 5.857μg/ml and 1.919μg/ml and 6.396μg/ml respectively for TLHC02 respectively. Statistical analysis showed that the method was precision, reproducible, selective, specific and accurate for the analysis of Tilorone dihydrochloride and its impurities. The wide range of linearity, sensitivity, precision, short retention times and simple mobile phase have shown that the method is suitable for the routine quantification of mass impurities of tilorone hydrochloride and its dosage pharmaceutical forms with high precision and accuracy.