scholarly journals Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns

2016 ◽  
Vol 17 (11) ◽  
pp. 1239-1247 ◽  
Author(s):  
Susanne Schnell ◽  
Danielle A. Smith ◽  
Alex J. Barker ◽  
Pegah Entezari ◽  
Amir R. Honarmand ◽  
...  
2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Evaldas Girdauskas ◽  
Kushtrim Disha ◽  
Michael-Andrew Borger ◽  
Thomas Kuntze

Whether the dilatation of proximal aorta in patients with bicuspid aortic valve is secondary to hemodynamic effects related to the abnormal aortic valve or a primary manifestation of the genetic disorder remains controversial. We discuss in this paper the recent data on the BAV function and transvalvular flow patterns in relation with the dilatation type of the proximal aorta. Different morphological forms of bicuspid aortic valve in relation with the specific transvalvular blood flow patterns are focus of the first paragraph of this paper. In the second part of this paper we present the pathogenetic insight into the different clinically observed phenotypes of bicuspid aortic valve disease (i.e., association of proximal aortic shapes with the specific cusp fusion patterns), based on the data from recent rheological studies.


Author(s):  
Ralf Felix Trauzeddel ◽  
Ulrike Löbe ◽  
Alex Barker ◽  
Carmen Gelsinger ◽  
Christian Butter ◽  
...  

Background Transcatheter aortic valve implantation (TAVI) is a new method for treating patients with severe aortic stenosis with high risk for or rejected from conventional heart surgery. Its impact on blood flow patterns and parameters in the ascending aorta are unknown. Using 4-dimensional phase contrast MRI (4D Flow MRI) we examined the hemodynamics in the ascending aorta after TAVI and compared them to stented bioprostheses and healthy controls. Methods We used 4D Flow MRI (spatial resolution 1.8x1.8x2.5mm3; temporal resolution 13-22 phases/heart cycle) of the ascending aorta in 14 patients with TAVI (mean age 76 years, 8 males, all Edwards Sapien), 12 patients with different stented bioprostheses (mean age 77 years, 8 males) and 9 healthy controls (mean age 55 years, 8 males) controls using a 1.5T MR system. We examined the distribution of the maximum systolic wall shear stresses as well as the maximum blood flow velocities in the mid-ascending aorta. Results Patients with TAVI and stented bioprosthesis revealed an asymetric distribution of the wall shear stresses with significantly elevated values at the anterior and right-anterior curvature and significantly lower values at the posterior curvature compared to the healthy controls. Concerning the maximum velocities both TAVI and stented bioprostheses revealed an asymetric distribution along the right-anterior curvature where TAVI showed a more anterior distribution compared to the healty controls which showed a central distribution. Conclusion The blood flow patterns in patients with TAVI and stented bioprostheses differs significantly from the ones in healthy controls. However, TAVI and stented bioprosthesis showed small but significant regional differences.


2019 ◽  
Vol 3 (sup1) ◽  
pp. 12-12
Author(s):  
Emile S. Farag ◽  
Luca Peroni ◽  
Lukas M. Gottwald ◽  
Jeroen Vendrik ◽  
S. Matthijs Boekholdt ◽  
...  

1987 ◽  
Vol 103 (5) ◽  
pp. 176-181 ◽  
Author(s):  
Norma Slepecky ◽  
Clarence Angelborg ◽  
Hans-Christian Larsen

2012 ◽  
Vol 14 (Suppl 1) ◽  
pp. W46
Author(s):  
Vikas Sinha ◽  
Gilion Hautvast ◽  
Jeroen Sonnemans ◽  
Hubrecht de Bliek ◽  
Andrei Jalba ◽  
...  

1988 ◽  
Vol 151 (1) ◽  
pp. 139-141 ◽  
Author(s):  
AS Brody ◽  
SH Embury ◽  
WC Mentzer ◽  
ML Winkler ◽  
CA Gooding

Sign in / Sign up

Export Citation Format

Share Document