Outcomes after tricuspid valve surgery concomitant with left ventricular assist device implantation in the EUROMACS registry: a propensity score matched analysis

2019 ◽  
Vol 56 (6) ◽  
pp. 1081-1089 ◽  
Author(s):  
Kevin M Veen ◽  
Kadir Caliskan ◽  
Theo M M H de By ◽  
Mostafa M Mokhles ◽  
Osama I Soliman ◽  
...  

Abstract OBJECTIVES Tricuspid regurgitation (TR) is common in patients receiving a left ventricular assist device (LVAD). Controversy exists as to whether concomitant tricuspid valve surgery (TVS) is beneficial in currently treated patients. Therefore, our goal was to investigate the effect of TVS concomitant with a LVAD implant. METHODS The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients. Matched patients with and without concomitant TVS were compared using a propensity score matching strategy. RESULTS In total, 3323 patients underwent LVAD implantation of which 299 (9%) had TVS. After matching, 258 patients without TVS were matched to 258 patients with TVS. In the matched population, hospital deaths, days on inotropic support, temporary right ventricular assist device implants and hospital stay were comparable, whereas stay in the intensive care unit was higher in the TVS cohort (11 vs 15 days; P = 0.026). Late deaths (P = 0.17), cumulative incidence of unexpected hospital readmission (P = 0.15) and right heart failure (P = 0.55) were comparable between patients with and without concomitant TVS. In the matched population, probability of moderate-to-severe TR immediately after surgery was lower in patients with concomitant TVS compared to patients without TVS (33% vs 70%; P = 0.001). Nevertheless, the probability of moderate-to-severe TR decreased more quickly in patients without TVS (P = 0.030), resulting in comparable probabilities of moderate-to-severe TR within 1.5 years of follow-up. CONCLUSIONS In matched patients, TVS concomitant with LVAD implant does not seem to be associated with better clinical outcomes. Concomitant TVS reduced TR significantly early after LVAD implant; however, differences in probability of TR disappeared during the follow-up period.

Perfusion ◽  
2021 ◽  
pp. 026765912110248
Author(s):  
Gregory Reid ◽  
Constantin Mork ◽  
Brigita Gahl ◽  
Christian Appenzeller-Herzog ◽  
Ludwig K von Segesser ◽  
...  

Objectives: The main aim was a systematic evaluation of the current evidence on outcomes for patients undergoing right ventricular assist device (RVAD) implantation following left ventricular assist device (LVAD) implantation. Methods: This systematic review was registered on PROSPERO (CRD42019130131). Reports evaluating in-hospital as well as follow-up outcome in LVAD and LVAD/RVAD implantation were identified through Ovid Medline, Web of Science and EMBASE. The primary endpoint was mortality at the hospital stay and at follow-up. Pooled incidence of defined endpoints was calculated by using random effects models. Results: A total of 35 retrospective studies that included 3260 patients were analyzed. 30 days mortality was in favour of isolated LVAD implantation 6.74% (1.98–11.5%) versus 31.9% (19.78–44.02%) p = 0.001 in LVAD with temporary need for RVAD. During the hospital stay the incidence of major bleeding was 18.7% (18.2–19.4%) versus 40.0% (36.3–48.8%) and stroke rate was 5.6% (5.4–5.8%) versus 20.9% (16.8–28.3%) and was in favour of isolated LVAD implantation. Mortality reported at short-term as well at long-term was 19.66% (CI 15.73–23.59%) and 33.90% (CI 8.84–59.96%) in LVAD respectively versus 45.35% (CI 35.31–55.4%) p ⩽ 0.001 and 48.23% (CI 16.01–80.45%) p = 0.686 in LVAD/RVAD group respectively. Conclusion: Implantation of a temporary RVAD is allied with a worse outcome during the primary hospitalization and at follow-up. Compared to isolated LVAD support, biventricular mechanical circulatory support leads to an elevated mortality and higher incidence of adverse events such as bleeding and stroke.


2020 ◽  
Vol 75 (11) ◽  
pp. 774
Author(s):  
Ganesh Gajanan ◽  
Kulpreet Barn ◽  
Jerome Thomas ◽  
Mauricio Garrido ◽  
Rohinton Morris ◽  
...  

2019 ◽  
Vol 6 (Supplement_2) ◽  
pp. S92-S93
Author(s):  
Yunus C Yalcin ◽  
Nelianne Verkaik ◽  
Hannelore I Bax ◽  
Peter D Croughs ◽  
Ad J J C Bogers ◽  
...  

Abstract Background Left ventricular assist device (LVAD) implantation has become an effective treatment option for patients with severe heart failure. However, infections remain a substantial risk. Therefore, the aim of this study was to gain insight in the incidence and outcome of LVAD infections in our center and develop an up-to-date flowchart for the management of LVAD-related infections. Methods A retrospective study was performed which included all patients with an LVAD implanted between 2006 until 2019, along with a rigorous review of the current literature. Clinical records and microbiological laboratory results of all patients were reviewed. In view of local infectious complications, a flowchart was developed for the contemporary management of LVAD-related infections (Figure 1). Results Overall, 106 patients (median age 54 years [IQR 47–60], 78% male) were included, of whom 92 (87%) as bridge-to-transplantation/decision and 14 (13%) as destination therapy. LVAD-related infections occurred in n = 30 (28%) of the patients. The median time until first infection was 308 days [IQR 115–528], and the median duration of hospital stay was 16 days [IQR 4–29]. Eighty percent of LVAD-related infections were driveline-related. The most common causative pathogen was Staphylococcus aureus, which was present in almost half of the cases (40%). Patients who experienced infections were younger (46 [IQR 37–57] vs. 56 [IQR 52–62]; P < 0.001).The survival rate at 3 years was 76% in the infected vs. 94% not infected patients; P = 0.037). A secondary infection occurred in 10 patients (33%). At 3 years of follow-up, 31 patients were successfully transplanted. Six patients with deep S. aureus driveline infections were treated according to the standardized protocol of whom 2 with suppressive therapy by cephalexin, with clinical success so far. Conclusion LVAD infections occur frequently and lead to prolonged periods of hospital admissions and death. The lack of standardized treatment regimens complicates the treatment of LVAD-related infections. A comprehensive flowchart to treat future LVAD-related infections in a protocolized fashion was developed, based on our single-center experience. While the preliminary results look promising, more follow-up time of the treated patients is needed. Disclosures All authors: No reported disclosures.


2018 ◽  
Vol 122 (6) ◽  
pp. 1021-1027 ◽  
Author(s):  
Himabindu Vidula ◽  
Valentina Kutyifa ◽  
Brent A. Johnson ◽  
Robert L. Strawderman ◽  
Donald Harrington ◽  
...  