1000 mm2 plus aortic annulus: successful treatment of a giant bicuspid aortic valve with a Sapien 3 transcatheter heart valve

2020 ◽  
Vol 41 (29) ◽  
pp. 2814-2814
Author(s):  
Hector A Alvarez-Covarrubias ◽  
Erion Xhepa ◽  
Jonathan M Michel ◽  
A Markus Kasel
2017 ◽  
Vol 69 (11) ◽  
pp. 982
Author(s):  
Hiroyuki Kawamori ◽  
Sunghan Yoon ◽  
Tarun Chakravarty ◽  
Yoshio Maeno ◽  
Mohammad Kashif ◽  
...  

Author(s):  
Tamim M. Nazif ◽  
Thomas J. Cahill ◽  
David Daniels ◽  
James M. McCabe ◽  
Mark Reisman ◽  
...  

Background: Paravalvular regurgitation (PVR) after transcatheter aortic valve replacement is associated with adverse clinical outcomes. The SAPIEN 3 Ultra (Ultra) is a new generation balloon-expandable transcatheter heart valve with a modified external skirt that is designed to reduce PVR, but reports of clinical and echocardiographic outcomes are limited. The aim of this study was to compare short-term outcomes of patients undergoing transcatheter aortic valve replacement with the Ultra and the original SAPIEN 3 (S3) transcatheter heart valve in a large national registry. Methods: Data from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to compare patients who underwent elective, transfemoral transcatheter aortic valve replacement with the Ultra or S3 transcatheter heart valve. Clinical and echocardiographic outcomes were analyzed in a propensity-matched cohort at discharge and 30 days. Results: Patients who underwent transcatheter aortic valve replacement with Ultra (N=1324) from January 2019 to February 2020 were propensity score–matched with patients treated with S3 (N=32 982) during the same period, resulting in 1324 matched pairs. There was no difference in the rate of device success between patients treated with Ultra and S3 (97.1% versus 98.0%, P =0.11). At hospital discharge, PVR was significantly reduced with Ultra compared with S3, with mild PVR in 9.0% versus 13.9% and moderate or greater PVR in 0.1% versus 0.4% (overall P <0.01). At 30 days, there were no differences between Ultra and S3 recipients in the rates of all-cause mortality or stroke (1.8% versus 2.8%, P =0.10), major vascular complications (1.1% versus 1.0%, P =0.84), or permanent pacemaker implantation (6.4% versus 6.2%, P =0.81). Conclusions: In this propensity-matched analysis from the Transcatheter Valve Therapy Registry, the Ultra transcatheter heart valve was associated with similar procedural and 30-day clinical outcomes, but reduced incidence of PVR, compared with S3. The clinical benefit of less PVR should be evaluated in longer-term studies.


2020 ◽  
Vol 61 (4) ◽  
pp. 713-719
Author(s):  
Franz-Josef Neumann ◽  
Simon Redwood ◽  
Mohamed Abdel-Wahab ◽  
Thierry Lefèvre ◽  
Derk Frank ◽  
...  

2018 ◽  
Vol 21 (5) ◽  
pp. E341-E344
Author(s):  
Kentaro Meguro ◽  
Ryota Kakizaki ◽  
Takuya Hashimoto ◽  
Tomoyoshi Yanagisawa ◽  
Toshimi Koitabashi ◽  
...  

Background: Transcatheter aortic valve implantation (TAVI) is effective in treating severe aortic stenosis in inoperable or high-risk surgical patients, however, the little is known about outcomes after Sapien 3 20 mm transcatheter heart valve (THV) implantation. The purpose of this study was to investigate the short term outcomes of Sapien 3 20 mm THV implantation in Japanese people with a small body size. Methods: We retrospectively collected the hospital records of consecutive patients who underwent TAVI using the Sapien 3 20 mm THV between October 2016 and March 2017. Clinical and echocardiographic data from before and one week after TAVI were collected. Results: Six Japanese patients (all female, mean age 89 ± 5 years, body surface area [BSA] 1.29 ± 0.16m2) received a Sapien 3 20 mm THV. All the procedures were feasible and successful, and the 30-day mortality rate was 0%. The functional class and the echocardiographic findings significantly improved (aortic valve area, 0.5 ± 0.1 cm2 to 0.8 ± 0.1cm2; mean pressure gradient, 55 ± 15 mmHg to 19 ± 7 mmHg; P = .043, respectively). However, the values of the indexed effective orifice area in all patients after Sapien 3 20 mm THV implantation were less than 0.85 cm2/m2, suggesting prosthesis-patient mismatch (PPM). Conclusions: The implantation of a Sapien 3 20 mm THV was safe and effective in high surgical risk elderly Japanese patients with a small body size. PPM after Sapien 3 20mm THV may be prevalent among Asians with small body sizes. Careful clinical follow-up will be necessary after Sapien 3 20 mm THV implantation.