scholarly journals Prosthesis position and its influence on complications after transcatheter aortic valve implantation with self-expanding valves

2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
P Breitbart ◽  
J Minners ◽  
M Hein ◽  
H Schroefel ◽  
F J Neumann ◽  
...  

Abstract Background/Introduction Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose Purpose of this study was to investigate the THV position and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). Methods We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. Results The mean implantation depth of the THV in the whole cohort was 4.3±3.0 mm. Using the best cut-off of >4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P<0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI]: 1.312 [1.119–1.539], P=0.001). The implantation depth showed no influence on the grade of PVL (r=0.052, P=0.598). Conclusions In patients with TAVI using the Evolut R SEV, a lower THV positioning (>4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, prosthesis position was not associated with the extent of PVL. FUNDunding Acknowledgement Type of funding sources: None.

Author(s):  
Philipp Breitbart ◽  
Jan Minners ◽  
Manuel Hein ◽  
Holger Schröfel ◽  
Franz-Josef Neumann ◽  
...  

AbstractPrior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P < 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI] 1.312[1.119–1.539], P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Graphic abstract Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI.


Author(s):  
Akiko Masumoto ◽  
Takeshi Kitai ◽  
Mitsuhiko Ota ◽  
Kitae Kim ◽  
Natsuhiko Ehara ◽  
...  

Abstract Background Increasing number of symptomatic patients with severe aortic stenosis is treated with transcatheter aortic valve implantation (TAVI). Stroke is one of the most serious complications of TAVI, and the majority of cerebral events in patients undergoing TAVI have an embolic origin. Case summary A 90-year-old female underwent trans-femoral TAVI for symptomatic severe aortic stenosis. Just before the implantation of the transcatheter heart valve (THV), transoesophageal echocardiography (TOE) showed a mobile, high-echoic mass attached to the THV, which gradually enlarged to 26 mm, then spontaneously detached from the THV and flowed up the ascending aorta, disappearing from the TOE field of. After the procedure, the patient presented with ischaemic stroke. The patient’s stroke was thought to have resulted from the embolism migrating to the distal cerebral arteries. Discussion The detailed images acquired with TOE during TAVI enabled the prompt identification of the unusual intracardiac mass.


2021 ◽  
Author(s):  
James Carey ◽  
Anthony Buckley ◽  
Stephen O'Connor ◽  
Mark Hensey

Transcatheter aortic valve implantation and implantation of other transcatheter heart valves, generally requires insertion of a temporary venous pacemaker. Implantation of a temporary venous pacemaker adds complexity, time and risk to the procedure. Guidewire modification to allow pacing is increasingly popular, however it requires technical expertise and provides unipolar pacing resulting in high thresholds and potential capture loss. The Wattson temporary pacing guidewire is a novel device which offers guidewire support for valve delivery and concomitant bipolar pacing. It may offer a safe and effective solution to guidewire pacing for transcatheter aortic valve implantation and other transcatheter heart valve implantations. Herein, we review the literature surrounding left ventricular guidewire pacing along with the features and clinical data of the Wattson wire.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
G Avinee ◽  
E Durand ◽  
T Levesque ◽  
P Y Litzler ◽  
J N Dacher ◽  
...  

Abstract Background Since the first-in-man transcatheter aortic valve implantation (TAVI) performed in 2002, the number of procedures has dramatically increased. However, long-term data regarding outcome and valve durability remain poor. Purpose We aimed to evaluate the evolution of 30-day outcomes over years and long-term mortality and valve durability after TAVI. Methods All consecutive patients presenting with severe symptomatic aortic stenosis treated by TAVI in our center were included prospectively. Clinical and echocardiographic follow-up was performed at 30 days and annually thereafter. Survival curves were constructed using Kaplan-Meier analysis. We also evaluated valve durability according to the European standardized definition of structural valve deterioration. Results Between 2002 and 2018, 1530 consecutive patients underwent TAVI including 1285 (84.0%) patients via a femoral approach. A balloon-expandable transcatheter heart valve was predominantly used (1421 patients; 92.9%). The annual transfemoral approach rate increased progressively to reach 93.3%. Age of patients remained stable over time with a global mean age of 83.7±6.5 years old. Logistic EuroSCORE decreased from 49.2±8.2% to 14.3±8.6% (p<0.0001). Thirty-day mortality dramatically decreased below 3% since 2015 and was 0% in 2018. Similarly, major vascular complications decreased from 50.0% in the first year to less than 1% since 2017 (p=0.001). The length of hospital-stay progressively shortened up to a median of 2 days in 2018. The Kaplan-Meier survival estimation was 82.3%, 60.3%, 33.0%; 11.7% and 8.9% respectively at 1, 3, 5, 8 and 10 years. On long-term follow-up the mean aortic gradient remained unchanged (Figure), and only five patients presented a severe prosthetic valve deterioration. Among them, four patients successfully benefited from a valve in valve TAVI procedure. The competing risk analysis at 10 years estimates risk for severe and moderate-or-severe valve deterioration of 1.9±0.9% and 4.3±1.3% respectively. TEE mean transaortic gradient Conclusions Long-term (up to 10 years) follow-up of our large pioneer series of patients treated by TAVI shows a dramatic improvement of outcomes and no warning signs of valve deterioration suggesting very encouraging valve durability, using predominantly, a balloon expandable prosthesis. Further studies are warranted to study valve durability after TAVI before extension to lower risk patients.


Sign in / Sign up

Export Citation Format

Share Document