scholarly journals P678Post-implant geometry of self-expandable transcatheter heart valve in patients with bicuspid versus tricuspid aortic valve stenosis

2018 ◽  
Vol 39 (suppl_1) ◽  
Author(s):  
Z.-G Zhao ◽  
Y J Li ◽  
Y B Liao ◽  
T Y Xiong ◽  
W Y Lv ◽  
...  
Author(s):  
Tamim M. Nazif ◽  
Thomas J. Cahill ◽  
David Daniels ◽  
James M. McCabe ◽  
Mark Reisman ◽  
...  

Background: Paravalvular regurgitation (PVR) after transcatheter aortic valve replacement is associated with adverse clinical outcomes. The SAPIEN 3 Ultra (Ultra) is a new generation balloon-expandable transcatheter heart valve with a modified external skirt that is designed to reduce PVR, but reports of clinical and echocardiographic outcomes are limited. The aim of this study was to compare short-term outcomes of patients undergoing transcatheter aortic valve replacement with the Ultra and the original SAPIEN 3 (S3) transcatheter heart valve in a large national registry. Methods: Data from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to compare patients who underwent elective, transfemoral transcatheter aortic valve replacement with the Ultra or S3 transcatheter heart valve. Clinical and echocardiographic outcomes were analyzed in a propensity-matched cohort at discharge and 30 days. Results: Patients who underwent transcatheter aortic valve replacement with Ultra (N=1324) from January 2019 to February 2020 were propensity score–matched with patients treated with S3 (N=32 982) during the same period, resulting in 1324 matched pairs. There was no difference in the rate of device success between patients treated with Ultra and S3 (97.1% versus 98.0%, P =0.11). At hospital discharge, PVR was significantly reduced with Ultra compared with S3, with mild PVR in 9.0% versus 13.9% and moderate or greater PVR in 0.1% versus 0.4% (overall P <0.01). At 30 days, there were no differences between Ultra and S3 recipients in the rates of all-cause mortality or stroke (1.8% versus 2.8%, P =0.10), major vascular complications (1.1% versus 1.0%, P =0.84), or permanent pacemaker implantation (6.4% versus 6.2%, P =0.81). Conclusions: In this propensity-matched analysis from the Transcatheter Valve Therapy Registry, the Ultra transcatheter heart valve was associated with similar procedural and 30-day clinical outcomes, but reduced incidence of PVR, compared with S3. The clinical benefit of less PVR should be evaluated in longer-term studies.


2021 ◽  
Author(s):  
James Carey ◽  
Anthony Buckley ◽  
Stephen O'Connor ◽  
Mark Hensey

Transcatheter aortic valve implantation and implantation of other transcatheter heart valves, generally requires insertion of a temporary venous pacemaker. Implantation of a temporary venous pacemaker adds complexity, time and risk to the procedure. Guidewire modification to allow pacing is increasingly popular, however it requires technical expertise and provides unipolar pacing resulting in high thresholds and potential capture loss. The Wattson temporary pacing guidewire is a novel device which offers guidewire support for valve delivery and concomitant bipolar pacing. It may offer a safe and effective solution to guidewire pacing for transcatheter aortic valve implantation and other transcatheter heart valve implantations. Herein, we review the literature surrounding left ventricular guidewire pacing along with the features and clinical data of the Wattson wire.


Sign in / Sign up

Export Citation Format

Share Document