Cryoablation for persistent and longstanding persistent atrial fibrillation: results from a multicentre European registry

EP Europace ◽  
2019 ◽  
Vol 22 (3) ◽  
pp. 375-381 ◽  
Author(s):  
Vinit Sawhney ◽  
Richard J Schilling ◽  
Rui Providencia ◽  
Matthew Cadd ◽  
Dhanuka Perera ◽  
...  

Abstract Aims Although cryoballoon pulmonary vein isolation is a well-established treatment for paroxysmal atrial fibrillation (AF), it’s role in persistent AF is unclear. We examined procedural success and long-term outcomes of cryoablation in persistent and longstanding persistent AF. Methods and results International multicentre registry from three UK and eight European centres. Consecutive patients undergoing cryoablation for persistent AF included. Procedural data, complications, and follow-up were prospectively recorded. Patients were followed-up at 3, 6, and 12 months with an electrocardiogram with open access to arrhythmia nurses thereafter. Ambulatory monitoring was dictated by symptoms. Success was defined as freedom from AF or atrial tachycardia lasting >30 s off antiarrhythmic drugs (AADs). Six hundred and nine consecutive cryoablation procedures. Mean procedure and fluoroscopy times were 95 ± 65 and 13 ± 10 min. Single procedure success rates were 368/602 (61%) off AADs over a median of 2.4 (1.0–4.0) years. Arrhythmia-free survival off AADs was 64% and 57% for persistent and longstanding persistent AF at 24 months of follow-up (P = 0.02). Rate of repeat ablations was 20% in persistent and 32% in longstanding persistent AF (P = 0.006). Cox regression analyses showed a significant association between duration of AF and left atrial diameter and arrhythmia recurrence [hazard ratio (HR) 1.05, P-value 0.01 and HR 1.02, P-value 0.004]. Conclusion Cryoablation for persistent AF is safe, fast and has good outcomes at long-term follow-up. Cryoablation is reasonable as a first line option for these patients. Short procedure times may help increase capacity of cardiac units to meet the rising demand for AF ablation. Randomised control trials are needed to compare outcomes with different techniques.

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D Musat ◽  
N Milstein ◽  
R Shaw ◽  
A Bhatt ◽  
M Preminger ◽  
...  

Abstract Background Cryoballoon (CB) pulmonary vein isolation (PVI) is increasingly being used in patients (pts) with persistent atrial fibrillation (AF). However, there are limited data about the pattern of atrial fibrillation (AF) recurrence in these pts. Objective To assess, using an implantable loop recorder (ILR), the patterns of AF recurrence following CB PVI in pts with persistent atrial fibrillation. Methods We enrolled consecutive pts with persistent AF ablation undergoing their first CB ablation. Other cavotricuspid isthmus ablation when indicated, no other ablation was performed. A Reveal LINQ ILR (Medtronic) was implanted <3 months following ablation; all pts had a minimum of 1-year follow-up. The recurrence of any atrial arrhythmia was determined and adjudicated; 4 distinct AF patterns were characterized (Figure). Results We studied 64 pts (66±9 years; 50 [78%] male; CHA2DS2-VASc 2.6±1.9) with persistent AF; 52 (81%) pts were on an antiarrhythmic drug (AAD) peri-ablation. During 803±361 days of follow-up, 33 (52%) pts had their 1st AF recurrence 91–365 days post-ablation and another 17 (27%) pts had their 1st AF recurrence >365 days post-ablation. No AF was seen in 14 (31%) pts. Most pts (33 of 50, 66%) with AF recurrence presented with 1 of 3 distinct patterns of paroxysmal AF (Figure), which ranged from 22 min to 124 hours. In 2/3 of these pts, all AF recurrences lasted <24 hours. Only 17 (34%) pts recurred with persistent AF. Conclusion Following single CB PVI, most pts with persistent AF remained free of persistent AF during long-term follow-up. Most pts with recurrent AF have 1 of 3 distinct patterns with episodes commonly last <24 hours. These data suggest that CB PVI ablation may halt AF progression in pts initially presenting with persistent AF.


2006 ◽  
Vol 70 (2) ◽  
pp. 169-173 ◽  
Author(s):  
Takeshi Sasaki ◽  
Shinichi Niwano ◽  
Sae Sasaki ◽  
Ryuta Imaki ◽  
Masaru Yuge ◽  
...  

2015 ◽  
Vol 4 (1) ◽  
pp. 47 ◽  
Author(s):  
Amir A Schricker ◽  
Junaid Zaman ◽  
Sanjiv M Narayan ◽  
◽  
◽  
...  

Atrial fibrillation (AF) ablation is increasingly used to maintain sinus rhythm yet its results are sub-optimal, especially in patients with persistent AF or prior unsuccessful procedures. Attempts at improvement have often targeted substrates that sustain AF after it is triggered, yet those mechanisms are debated. Many studies now challenge the concept that AF is driven by self-sustaining disordered wavelets, showing instead that localised drivers (rotors) may drive disorder via a process known as fibrillatory conduction. Novel mapping using wide-area recordings, physiological filtering and phase analysis demonstrates rotors in human AF. Contact mapping with focal impulse and rotor modulation (FIRM) shows that localised ablation at sources can improve procedural success in many populations on long-term follow up and some newer approaches to rotor mapping are qualitatively similar. This review critically evaluates the data on rotor mapping and ablation, which advances our conceptual understanding of AF and holds the promise of substantially improving ablative outcomes in patients with persistent AF.


2009 ◽  
Vol 30 (9) ◽  
pp. 1105-1112 ◽  
Author(s):  
M. D. O'Neill ◽  
M. Wright ◽  
S. Knecht ◽  
P. Jais ◽  
M. Hocini ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document