High Performance Liquid Chromatographic Determination of Carbaryl Insecticide in Formulations

1980 ◽  
Vol 63 (3) ◽  
pp. 650-652
Author(s):  
William H Mcdermott

Abstract A high performance liquid chromatographic method for carbaryl in formulations has been developed and used to assay 3 formulations in a 10-day repeatability study. The method uses a cyano modified silica gel column packing and a mobile phase of heptane-methylene chloride-isopropanol-methanol (60+35+4.8+0.2). The coefficients of variation for 2 wettable powders and one aqueous flowable formulation were 0.61, 0.62, and 0.75%, respectively. It is recommended that a collaborative study be conducted on this method.

1981 ◽  
Vol 64 (4) ◽  
pp. 805-807
Author(s):  
Leslie G West ◽  
Marie A Llorente

Abstract A rapid and simple high performance liquid chromatographic method for the determination of lactose in milk was developed. Samples were diluted with 0.5% perchloric acid and centrifuged, and an aliquot of the supernate was mixed with acetonitrile. Lactose was separated on a 10 μm particle-size silica column with aqueous acetonitrile as the mobile phase. The recovery of lactose from whole, skim, and chocolate milk averaged 99.2, 101.1, and 100.4%, respectively. Coefficients of variation for routinely performed duplicate determinations are between 1.0 and 1.5%.


1981 ◽  
Vol 64 (4) ◽  
pp. 889-892
Author(s):  
Badaruddin Shaikh ◽  
Margarette R Hallmark

Abstract Methapyrilene hydrochloride (MP·HCl) was extracted from feed with methanol and determined by reverse phase partition chromatography in less than 15 min, using isocratic elution with acetonitrile-1.1% ammonium carbonate (1 + 1) as the mobile phase. This procedure was tested on feed treated with MP·HCl at levels of 125,500, and 2000 ppm. Recoveries were 104,95, and 96% with coefficients of variation of 2.4,1.6, and 0.6%, respectively. MP·HCl in feed was stable for 14 days. This method was also successfully used to determine MP·HCl in 3 sleep aid tablets.


1985 ◽  
Vol 68 (3) ◽  
pp. 586-589
Author(s):  
Stephen C Slahck

Abstract A liquid chromatographic method for the determination of triadimefon (Bayleton™) in triadimefon technical and formulated products has been developed and subjected to a collaborative study with 7 participating collaborators. Formulations were extracted with mobile solvent and analyzed by normal phase chromatography, with 4-chlorophenyl sulfoxide as an internal standard. Collaborators were furnished with standards and samples of technical products, 50% wettable powders, and 25% wettable powders for analysis. Coefficients of variation of the values obtained on these samples were 1.42, 0.82, and 1.05%, respectively. The method has been adopted official first action.


1982 ◽  
Vol 28 (10) ◽  
pp. 2143-2148 ◽  
Author(s):  
P M Edelbroek ◽  
E J de Haas ◽  
F A de Wolff

Abstract To study correlations between the concentrations, in serum, of amitriptyline and its most important metabolites with clinical response in patients, we developed a "high-performance" liquid-chromatographic method for routine determination of amitriptyline, nortriptyline, total 10-hydroxy-amitriptyline, desmethylnortriptyline, and E(trans)- and Z(cis)-10-hydroxynortriptyline. These compounds are extracted from 1 mL of alkalinized serum into hexane/isoamyl alcohol (99/1 by vol). Perazine is the internal standard. To minimize irreversible adsorption of the drugs onto the glassware, 5 micrograms of maprotiline is added to the organic phase just before evaporation. After a 10-min resolution on a silica column eluted with acetonitrile/methanol/NH4OH (1 mol/L), absorbance is measured at 240 nm. Only chlorimipramine, doxepin, procainamide, and N-acetylprocainamide may interfere with assay of the compounds that probably are therapeutically relevant: amitriptyline, nortriptyline, and E-10-hydroxynortriptyline. Uremia, lipemia, and icterus also do not affect the analysis.


1980 ◽  
Vol 26 (1) ◽  
pp. 117-119
Author(s):  
J O Miners ◽  
T Foenander ◽  
D J Birkett

Abstract We report a "high-performance" liquid-chromatographic method for measuring 5-fluorocytosine in plasma and cerebrospinal fluid. After deproteinization with trichloroacetic acid, the supernates are chromatographed on a reversed-phase (C18) column. Response to concentration is linear in the range of 5 to 200 mg/L, with ultraviolet detection at 276 nm. The assay requires only 0.1 mL of plasma, is reproducible, and may be performed in less than 12 min. 5-Fluorocytosine concentrations determined by this procedure correlated well with those obtained by spectrofluorometry, although the present method is more specific with no observable interference from co-administered amphotericin B and most other commonly encountered drugs, including salicylat:. This method is applicable to the routine therapeutic monitoring of pediatric and adult patients as well as to pharmacokinetic studies.


1986 ◽  
Vol 69 (5) ◽  
pp. 908-911
Author(s):  
Peter L Carter ◽  
Keith C Overton ◽  
◽  
P G Baker ◽  
O O Bennett ◽  
...  

Abstract A liquid chromatographic method for determination of bendiocarb in technical materials and wettable powders was tested by 12 collaborators. Bendiocarb is dissolved in acetonitrile containing 0.1% propiophenone as internal standard. This solution is analyzed on a liquid chromatograph utilizing a reverse phase (C18) column. The compound is detected at 254 nm and peak area is used for quantitation. The 3 different materials studied contained 20, 80, and nominally 100% bendiocarb. Each was examined in duplicate to provide the necessary matched pairs. Collaborators approved of the ease and simplicity of the method and, in particular, the way the method can be applied to automatic injection assemblies. The statistical data show acceptable precision of the method: Reproducibility coefficients of variation were 20% material, 2.04%; 80% material, 1.02%; and nominal 100% material (technical product), 0.64%. The method has been adopted official first action.


1980 ◽  
Vol 26 (1) ◽  
pp. 117-119 ◽  
Author(s):  
J O Miners ◽  
T Foenander ◽  
D J Birkett

Abstract We report a "high-performance" liquid-chromatographic method for measuring 5-fluorocytosine in plasma and cerebrospinal fluid. After deproteinization with trichloroacetic acid, the supernates are chromatographed on a reversed-phase (C18) column. Response to concentration is linear in the range of 5 to 200 mg/L, with ultraviolet detection at 276 nm. The assay requires only 0.1 mL of plasma, is reproducible, and may be performed in less than 12 min. 5-Fluorocytosine concentrations determined by this procedure correlated well with those obtained by spectrofluorometry, although the present method is more specific with no observable interference from co-administered amphotericin B and most other commonly encountered drugs, including salicylat:. This method is applicable to the routine therapeutic monitoring of pediatric and adult patients as well as to pharmacokinetic studies.


1983 ◽  
Vol 66 (4) ◽  
pp. 864-866
Author(s):  
Eileen S Bargo ◽  
◽  
E Aranda ◽  
C Bonnin ◽  
S Hauser ◽  
...  

Abstract A reverse phase high pressure liquid chromatographic method for the determination of oxazepam in tablets and capsules was collaboratively studied by 9 laboratories. Collaborators were supplied with 6 samples that included synthetic and commercial formulations. Tablet and capsule composites are diluted with methanol and filtered. Oxazepam is determined at 254 nm by using a C18 column. Mean recoveries of oxazepam from synthetic tablet and capsule formulations were 97.2 and 99.0%, respectively. Mean coefficients of variation for tablets and capsules ranged from 1.85 to 2.86%. The method has been adopted official first action.


1982 ◽  
Vol 65 (3) ◽  
pp. 567-571
Author(s):  
Peter Sporns

Abstract A rapid, accurate high performance liquid chromatographic method is described for determination of glutamic acid in food. Average recovery of added glutamic acid was 99.2% by this method. The method could be used to analyze samples such as soy sauce, which contain a large amount of other potentially interfering soluble compounds.


1986 ◽  
Vol 69 (4) ◽  
pp. 594-597 ◽  
Author(s):  
Elia D Coppola ◽  
Martin S Starr ◽  
◽  
G H Chang ◽  
J DeVries ◽  
...  

Abstract Twelve laboratories collaboratively studied a liquid chromatographic method for determination of quinic, malic, and citric acids in cranberry juice cocktail and apple juice. Samples are passed through a disposable silica cartridge, filtered, and directly injected into the chromatograph. The mobile phase is 0.2M KH2PO4 (pH 2.4). Two reverse phase columns are used, with UV detection at 214 nm. Six samples of cranberry juice cocktail and 6 samples of apple juice were sent to each collaborator. Repeatability and reproducibility coefficients of variation ranged from 1.2 to 7.6% and from 2.9 to 14.7%, respectively, for quinic, malic, and citric acid levels above 0.10%. The precision of the method is satisfactory. The method has been adopted official first action.


Sign in / Sign up

Export Citation Format

Share Document