Liquid Chromatographic Determination of Diazepam in Tablets: Collaborative Study

1985 ◽  
Vol 68 (3) ◽  
pp. 545-546
Author(s):  
Michael Tsougros

Abstract A stability indicating liquid chromatographic method for the determination of diazepam in tablets was collaboratively studied by 6 laboratories. The method uses a Cig reverse phase column, a methanolwater mobile phase, p-tolualdehyde as the internal standard, and photometric detection at 254 nm. The collaborators were supplied with a synthetic tablet powder and 3 commercial tablet samples. The mean recovery of diazepam from the synthetic tablet powder was 100.2%. For all samples analyzed, the coefficient of variation was < 1.5%. The method has been adopted official first action.

1988 ◽  
Vol 71 (1) ◽  
pp. 33-35
Author(s):  
Donald Shostak ◽  
Clifford Klein ◽  
◽  
C Cappon ◽  
N Falcone ◽  
...  

Abstract A liquid chromatographic method for the determination of flucytosine in capsules was collaboratively studied by 7 laboratories. The method uses a C18 reverse phase column, water-methanol-acetic acid mobile phase containing 1-octanesulfonic acid sodium salt, p-aminobenzoic acid as internal standard, and photometric detection at 285 nm. The mean recovery value (±SD) of flucytosine from a synthetic formulation representing capsules was 99.2 ± 1.72% (CV = 1.73%). Composited samples of 250 and 500 mg commercial capsules gave assay values of (mean ± SD) 103.17 ± 2.21 and 99.29 ± 1.29% of declared, respectively. CV values were 2.15 and 1.30%. Reproducibility and repeatability CVs were 2.19 and 1.50%, respectively, for the 250 mg capsules, and 1.34 and 0.63%, respectively, for the 500 mg capsules. The method has been adopted official first action.


1984 ◽  
Vol 67 (6) ◽  
pp. 1121-1122
Author(s):  
Donald Shostak ◽  
◽  
M P Uribe ◽  
T Poplawski ◽  
T S Savage ◽  
...  

Abstract A liquid chromatographic method for the determination of allopurinolin tablets was collaboratively studied by 7 laboratories. The methoduses a C,8 reverse phase column, a 0.05M ammonium phosphate mobilephase, hypoxanthine as the internal standard, and photometric detectionat 254 nm. Collaborators were supplied with samples of 2 commercialtablets and 1 synthetic tablet powder. The mean recovery value of allopurinol from the synthetic tablet powder was 100.0%. The combinedmean coefficient of variation for all 3 types of sample analyzedwas less than 2%. The method has been adopted official first action.


1984 ◽  
Vol 67 (3) ◽  
pp. 497-499
Author(s):  
Stephen C Slahck ◽  
◽  
J B Audino ◽  
O O Bennett ◽  
B D Folsom ◽  
...  

Abstract A liquid chromatographic method for the determination of propoxur in technical and formulated products has been subjected to a collaborative study with 8 participating collaborators. Formulations are extracted with acetonitrile and analyzed by reverse phase chromatography, with n-butyrophenone as an internal standard. Collaborators were furnished with samples of technical, 70% wettable powder, 1.5 emulsifiable, and 2% bait. Coefficient of variation values obtained on the 4 samples were 0.34, 0.68, 3.25, and 5.41%, respectively. The method has been adopted official first action.


1984 ◽  
Vol 67 (3) ◽  
pp. 492-493
Author(s):  
Stephen C Slahck ◽  
◽  
A A Carlstrom ◽  
L T Chenery ◽  
N D Ellis ◽  
...  

Abstract An LC method for the determination of methiocarb in methiocarb technical and formulated products has been subjected to a collaborative study with 9 participating collaborators. Formulations are extracted with acetonitrile and analyzed by reverse phase chromatography, with acetophenone as an internal standard. Collaborators were furnished samples of technical, 75% wettable powder, 75% seed treater, 75% concentrate, and 50% hopper box treater. Coefficient of variation values obtained on the 5 samples were 0.71, 0.83, 0.62, 1.57, and 0.82%, respectively. The method has been adopted official first action.


1986 ◽  
Vol 69 (5) ◽  
pp. 915-918
Author(s):  
Edward J Kikta ◽  
◽  
E Bane ◽  
A Burns ◽  
A Christensen ◽  
...  

Abstract A liquid chromatographic (LC) method for the analysis of technical and formulated carbofuran samples was evaluated in a collaborative study. Carbofuran is determined by reverse phase LC, using a water-methanol mobile phase and acetophenone as internal standard, and detected at 280 nm. Twelve samples, 5 formulations and technical matched pairs, were analyzed by 17 collaborating laboratories. Accuracy and variability of results are typical of large LC data sets. The method has been adopted official first action.


1985 ◽  
Vol 68 (3) ◽  
pp. 586-589
Author(s):  
Stephen C Slahck

Abstract A liquid chromatographic method for the determination of triadimefon (Bayleton™) in triadimefon technical and formulated products has been developed and subjected to a collaborative study with 7 participating collaborators. Formulations were extracted with mobile solvent and analyzed by normal phase chromatography, with 4-chlorophenyl sulfoxide as an internal standard. Collaborators were furnished with standards and samples of technical products, 50% wettable powders, and 25% wettable powders for analysis. Coefficients of variation of the values obtained on these samples were 1.42, 0.82, and 1.05%, respectively. The method has been adopted official first action.


1987 ◽  
Vol 70 (5) ◽  
pp. 834-836
Author(s):  
Ella S Moore

Abstract A liquid chromatographic method for the determination of coumarin anticoagulants in tablets was collaboratively studied by 7 laboratories. The method uses an octadecylsilane-bonded microparticulate column, tetrahydrofuran-methanol-water-acetic acid mobile phase, and photometric detection at 311 nm. Each collaborator received samples of warfarin sodium, phenprocoumon, and dicumarol as a synthetic composite and as commercial individual and composited tablets. Pooled average assay values for synthetic and commercial tablet samples of warfarin sodium were 101.6 and 99.5%, respectively, with a combined reproducibility SD of 2.38% (CV = 2.37%) and combined repeatability SD of 1.49% (CV = 1.49%). Pooled average (SD) assay values for dicumarol and phenprocoumon commercial samples were 98.0 (2.27) and 101.3% (4.00), respectively. The content uniformity determinations of 2 mg warfarin sodium and 25 mg dicumarol tablets indicated average tablet contents (range) of 99.5% (91.0-116.0) and 98.0% (89.8-108.8), respectively. The method has been approved interim official first action


1997 ◽  
Vol 80 (3) ◽  
pp. 549-554 ◽  
Author(s):  
Karl-Erik Hellenás ◽  
Carina Branzell ◽  
H Poutanen ◽  
T Suortti ◽  
R Kaario ◽  
...  

Abstract Twelve laboratories participated in a collaborative study to evaluate precision parameters of a liquid chromatographic method for analysis of the glycoalkaloids α-solanine and α-chaconine in potato tubers. Samples consisted of frozen potato tuber homogenates distributed as 3 blind duplicates and 3 split-level pairs. The analytical method included aqueous extraction, workup on disposable solidphase extraction cartridges, and reversed-phase chromatography with photometric detection at 202 nm. Results for α-solanine and α-chaconine were received from 10 and 9 laboratories, respectively. Relative standard deviations for reproducibilo ity for α-solanine and α-chaconine were similar, ranging from 8 to 13% in the applied concentration range of 12 to 260 mg/kg fresh weight.


1986 ◽  
Vol 69 (5) ◽  
pp. 908-911
Author(s):  
Peter L Carter ◽  
Keith C Overton ◽  
◽  
P G Baker ◽  
O O Bennett ◽  
...  

Abstract A liquid chromatographic method for determination of bendiocarb in technical materials and wettable powders was tested by 12 collaborators. Bendiocarb is dissolved in acetonitrile containing 0.1% propiophenone as internal standard. This solution is analyzed on a liquid chromatograph utilizing a reverse phase (C18) column. The compound is detected at 254 nm and peak area is used for quantitation. The 3 different materials studied contained 20, 80, and nominally 100% bendiocarb. Each was examined in duplicate to provide the necessary matched pairs. Collaborators approved of the ease and simplicity of the method and, in particular, the way the method can be applied to automatic injection assemblies. The statistical data show acceptable precision of the method: Reproducibility coefficients of variation were 20% material, 2.04%; 80% material, 1.02%; and nominal 100% material (technical product), 0.64%. The method has been adopted official first action.


1983 ◽  
Vol 66 (4) ◽  
pp. 864-866
Author(s):  
Eileen S Bargo ◽  
◽  
E Aranda ◽  
C Bonnin ◽  
S Hauser ◽  
...  

Abstract A reverse phase high pressure liquid chromatographic method for the determination of oxazepam in tablets and capsules was collaboratively studied by 9 laboratories. Collaborators were supplied with 6 samples that included synthetic and commercial formulations. Tablet and capsule composites are diluted with methanol and filtered. Oxazepam is determined at 254 nm by using a C18 column. Mean recoveries of oxazepam from synthetic tablet and capsule formulations were 97.2 and 99.0%, respectively. Mean coefficients of variation for tablets and capsules ranged from 1.85 to 2.86%. The method has been adopted official first action.


Sign in / Sign up

Export Citation Format

Share Document