Liquid Chromatographic Determination of Saccharin in Beverages and Desserts: Complementary Collaborative Study

1988 ◽  
Vol 71 (6) ◽  
pp. 1210-1212 ◽  
Author(s):  
Anna-Maija K SjÖberg

Abstract A complementary collaborative study was conducted on a liquid chromatographic method for determination of saccharin in accordance with the latest international recommendations. One industrial and 6 official food control laboratories analyzed 3 samples of a juice, a soft drink, and a dessert at concentration levels of 26-90 mg/L, 33-73 mg/L, and 56-147 mg/kg, respectively. Blind duplicates and a blank were supplied for each type of material at each concentration level. The beverage was chromatographed directly and the dessert was extracted with ethanol before chromatography. Average recoveries were 95-107%. The reproducibility relative standard deviations were 6.4-7.3% for the juice, 9.2-20.6% for the soft drink, and 13.4-16.2% for the dessert. The outlier percentage was 14.3%. The results were compared with those of an earlier collaborative study by Nordic laboratories and with general collaborative results obtained by AOAC

1988 ◽  
Vol 71 (5) ◽  
pp. 1046-1048
Author(s):  
Ada C Bello ◽  
Rita K Jhangiani

Abstract A liquid chromatographic method for the assay of morphine sulfate and some preservatives and impurities in the bulk drug and in injections has been developed and collaboratively studied in 8 laboratories. Each collaborator analyzed 5 samples: 1 bulk drug, 3 different concentrations of injectable dosages, and 1 prepared mixture containing, in addition to morphine sulfate, phenol, 2-mercaptobenzothiazole, and pseudomorphine. The proposed method quantitates morphine sulfate and resolves the other components for identification using a Clg reverse-phase column with a mobile solvent containing 240 mL methanol, 720 mL 0.005M 1-heptanesulfonic acid Na salt, and 10 mL acetic acid. Samples are prepared by direct dilution with mobile solvent minus 1-heptanesulfonic acid. All collaborators met system suitability requirements and performed the analysis without difficulty. No outliers were found when data were analyzed by the Dixon, Grubbs, double Grubbs, and Cochran tests. Relative standard deviations between laboratories (RSDR) for duplicate determinations of morphine sulfate ranged from 1.4 to 2.1%. Mean morphine sulfate recoveries for the bulk drug and the prepared mixture were 100.8 and 100.4%, respectively. The method has been approved interim official first action.


1997 ◽  
Vol 80 (3) ◽  
pp. 549-554 ◽  
Author(s):  
Karl-Erik Hellenás ◽  
Carina Branzell ◽  
H Poutanen ◽  
T Suortti ◽  
R Kaario ◽  
...  

Abstract Twelve laboratories participated in a collaborative study to evaluate precision parameters of a liquid chromatographic method for analysis of the glycoalkaloids α-solanine and α-chaconine in potato tubers. Samples consisted of frozen potato tuber homogenates distributed as 3 blind duplicates and 3 split-level pairs. The analytical method included aqueous extraction, workup on disposable solidphase extraction cartridges, and reversed-phase chromatography with photometric detection at 202 nm. Results for α-solanine and α-chaconine were received from 10 and 9 laboratories, respectively. Relative standard deviations for reproducibilo ity for α-solanine and α-chaconine were similar, ranging from 8 to 13% in the applied concentration range of 12 to 260 mg/kg fresh weight.


1987 ◽  
Vol 70 (1) ◽  
pp. 58-60 ◽  
Author(s):  
Anna-Maija K Sjoberg ◽  
Timo A Alanko

Abstract A reverse phase liquid chromatographic method for the determination of saccharin in a soft drink and a juice was collaboratively studied in 8 laboratories. Collaborators were supplied with 3 samples of the soft drink and 3 samples of the juice containing sodium saccharin levels of 40-100 mg/L. Average recoveries of sodium saccharin were 95.3% for the soft drink and 98.0% for the juice. The reproducibility coefficients of variation were 16.9% for the soft drink and 10.4% for the juice. In addition, a mini-collaborative study was conducted for the determination of saccharin in 3 samples of sweets produced commercially. Five collaborators analyzed the samples, which contained saccharin at levels of 100-600 mg/kg according to the maker's specifications. Saccharin was extracted with water and ethanol and chromatographed using a modified liquid chromatographic method. The reproducibility coefficient of variation was 12.4% for the sweets.


1991 ◽  
Vol 74 (2) ◽  
pp. 317-323 ◽  
Author(s):  
Mark E Oppenhuizen ◽  
John E Cowell

Abstract A new method for determination of glyphosate and amlnomethylphosphonlc acid (AMPA) residues In environmental water was collaboratively studied by 6 laboratories. The method Is simpler and shorter than previous methods. A filtered volume of water is evaporated to dryness and the residue Is dissolved In a buffered EDTA solution. Glyphosate and AMPA are determined by liquid chromatography with postcolumn reaction detection. The method was validated over the range 0.50-5000 ppb, although one of the collaborating laboratories could not reliably quantltate below 1.0 ppb. Statistical analysis of the results showed that typical reproducibility relative standard deviations (RSDR) ranged from 11 to 20% for both glyphosate and AMPA, which compares very well with predicted values for this concentration range. Total variability (as measured by sR) Increased with increasing fortification level. The method has been adopted official first action by AOAC.


1985 ◽  
Vol 68 (3) ◽  
pp. 545-546
Author(s):  
Michael Tsougros

Abstract A stability indicating liquid chromatographic method for the determination of diazepam in tablets was collaboratively studied by 6 laboratories. The method uses a Cig reverse phase column, a methanolwater mobile phase, p-tolualdehyde as the internal standard, and photometric detection at 254 nm. The collaborators were supplied with a synthetic tablet powder and 3 commercial tablet samples. The mean recovery of diazepam from the synthetic tablet powder was 100.2%. For all samples analyzed, the coefficient of variation was < 1.5%. The method has been adopted official first action.


1989 ◽  
Vol 72 (2) ◽  
pp. 231-234 ◽  
Author(s):  
Mercedes Jalón ◽  
Majesús Peńa ◽  
Julián C Rivas

Abstract A reverse-phase liquid chromatographic method is described for the determination of carminic acid in yogurt. A C18 column is used with acetonitrile-1.19M formic acid (19 + 81) as mobile phase and diode array detection. Sample preparation includes deproteinization with papain and purification in a polyamide column. The relative standard deviation for repeated determinations of carminic acid in a commercial strawberry-flavored yogurt was 3.0%. Recoveries of carminic acid added to a natural-flavored yogurt ranged from 87.2 to 95.3% with a mean of 90.2%. The method permits measurement of amounts as low as 0.10 mg/kg.


1985 ◽  
Vol 68 (3) ◽  
pp. 586-589
Author(s):  
Stephen C Slahck

Abstract A liquid chromatographic method for the determination of triadimefon (Bayleton™) in triadimefon technical and formulated products has been developed and subjected to a collaborative study with 7 participating collaborators. Formulations were extracted with mobile solvent and analyzed by normal phase chromatography, with 4-chlorophenyl sulfoxide as an internal standard. Collaborators were furnished with standards and samples of technical products, 50% wettable powders, and 25% wettable powders for analysis. Coefficients of variation of the values obtained on these samples were 1.42, 0.82, and 1.05%, respectively. The method has been adopted official first action.


1984 ◽  
Vol 67 (2) ◽  
pp. 225-227 ◽  
Author(s):  
Richard L Everett ◽  
◽  
L Allgire ◽  
R J Ballbach ◽  
J Booth ◽  
...  

Abstract A reverse phase liquid chromatographic method was developed for determining methocarbamol in injection and tablet dosage forms. The injections require dilution only; the tablets require a nitration step before introduction into the chromatograph. Response for methocarbamol was linear over the range 0-18 μg, using an ultraviolet detector at 274 nm. Recoveries by the author ranged from 96.1 to 101.9% for authentic injection formulations and 98.0 to 101.0% for authentic tablet formulations. A collaborative study of the method by 6 laboratories resulted in standard deviations of 1.70 and 2.22 for injection and tablet dosage forms, respectively. The method has been adopted official first action.


1987 ◽  
Vol 70 (5) ◽  
pp. 834-836
Author(s):  
Ella S Moore

Abstract A liquid chromatographic method for the determination of coumarin anticoagulants in tablets was collaboratively studied by 7 laboratories. The method uses an octadecylsilane-bonded microparticulate column, tetrahydrofuran-methanol-water-acetic acid mobile phase, and photometric detection at 311 nm. Each collaborator received samples of warfarin sodium, phenprocoumon, and dicumarol as a synthetic composite and as commercial individual and composited tablets. Pooled average assay values for synthetic and commercial tablet samples of warfarin sodium were 101.6 and 99.5%, respectively, with a combined reproducibility SD of 2.38% (CV = 2.37%) and combined repeatability SD of 1.49% (CV = 1.49%). Pooled average (SD) assay values for dicumarol and phenprocoumon commercial samples were 98.0 (2.27) and 101.3% (4.00), respectively. The content uniformity determinations of 2 mg warfarin sodium and 25 mg dicumarol tablets indicated average tablet contents (range) of 99.5% (91.0-116.0) and 98.0% (89.8-108.8), respectively. The method has been approved interim official first action


1984 ◽  
Vol 67 (3) ◽  
pp. 497-499
Author(s):  
Stephen C Slahck ◽  
◽  
J B Audino ◽  
O O Bennett ◽  
B D Folsom ◽  
...  

Abstract A liquid chromatographic method for the determination of propoxur in technical and formulated products has been subjected to a collaborative study with 8 participating collaborators. Formulations are extracted with acetonitrile and analyzed by reverse phase chromatography, with n-butyrophenone as an internal standard. Collaborators were furnished with samples of technical, 70% wettable powder, 1.5 emulsifiable, and 2% bait. Coefficient of variation values obtained on the 4 samples were 0.34, 0.68, 3.25, and 5.41%, respectively. The method has been adopted official first action.