Multifunctional Column Coupled with Liquid Chromatography for Determination of Aflatoxins B1, B2, G1, and G2 in Corn, Almonds, Brazil Nuts, Peanuts, and Pistachio Nuts: Collaborative Study

1994 ◽  
Vol 77 (6) ◽  
pp. 1512-1521 ◽  
Author(s):  
Mary W Trucksess ◽  
Michael E Stack ◽  
Stanley Nesheim ◽  
Richard H Albert ◽  
Thomas R Romer

Abstract An AOAC/IUPAC collaborative study was conducted to evaluate the effectiveness of a multifunctional column for the determination of aflatoxins. The test portion is extracted with acetonitrile–water (9 + 1), the extract is filtered, and the filtrate is passed through the column. The aflatoxins in the eluate are determined by reversed-phase liquid chromatography after derivatization with trifluoroacetic acid. Naturally contaminated corn, almonds, Brazil nuts, peanuts, and pistachio nuts spiked with total aflatoxins at 5,10,20, and 30 ng/g were sent to 12 collaborators in the United States, Denmark, France, Japan, and Switzerland. Eleven collaborators completed the study. Average recoveries of total aflatoxins for each spike level for the various commodities (excluding Brazil nuts at 5 ng/g) were 93,97,95, and 95%, respectively; the repeatability relative standard deviation (RSDr) ranged from 6.0 to 23.2% and the reproducibility relative standard deviation (RSDR) ranged from 12.0 to 69.4%. The multifunctional column coupled with a liquid chromatographic method for determination of aflatoxins in corn, almonds, Brazil nuts, peanuts, and pistachio nuts has been adopted first action by AOAC INTERNATIONAL.

2005 ◽  
Vol 88 (2) ◽  
pp. 526-535 ◽  
Author(s):  
Hamide Z Senyuva ◽  
John Gilbert

Abstract An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 and total aflatoxins in hazelnut paste at European regulatory limits. The test portion was extracted with methanol–water (6 + 4). The extract was filtered, diluted with phosphate-buffered saline (PBS) solution to a specified solvent concentration, and applied to an immunoaffinity column containing antibodies specific to aflatoxins. The aflatoxins were removed from the immunoaffinity column with methanol, and then quantified by reversed-phase LC with post-column derivatization (PCD) involving bromination. The PCD was achieved with electrochemically generated bromine (Kobra Cell®) followed by fluorescence detection (except for one participant who used pyridinum hydrobromide perbromide for bromination). Hazelnut paste, both naturally contaminated with aflatoxins and blank (<0.1 ng/g) for spiking by participants with aflatoxins, was sent to 14 collaborators in Belgium, The Netherlands, Spain, Turkey, the United Kingdom, and the United States. Test portions were spiked at levels of 4.0 and 10.0 ng/g for total aflatoxins by participants using supplied total aflatoxins standards. Recoveries for total aflatoxins and aflatoxin B1 averaged from 86 to 89%. Based on results for naturally contaminated samples (blind duplicates at 3 levels ranging from 4.0 to 11.8 ng/g total aflatoxins), the relative standard deviation for repeatability (RSDr) ranged from 2.3 to 3.4% for total aflatoxins and from 2.2 to 3.2% for aflatoxin B1. The relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 7.0% for total aflatoxins and from 7.3 to 7.8% for aflatoxin B1. The method showed exceptionally good within-laboratory and between-laboratory precision for hazelnut paste, as evidenced by HORRAT values, which in all cases were significantly below target levels, the low levels of determination for both aflatoxin B1 and total aflatoxins.


2003 ◽  
Vol 86 (6) ◽  
pp. 1179-1186 ◽  
Author(s):  
Joerg Stroka ◽  
Christoph von Holst ◽  
Elke Anklam ◽  
Matthias Reutter ◽  
A Barmark ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone–water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP–LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminatedwithaflatoxinB1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally con-taminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within-and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.


1991 ◽  
Vol 74 (1) ◽  
pp. 81-88 ◽  
Author(s):  
Mary W Trucksess ◽  
Michael E stack ◽  
Stanley Nesheim ◽  
Samuel W Page ◽  
Richard H Albert ◽  
...  

Abstract An AOAC/IUPAC (International Union of Pure and Applied Chemistry) collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column for the determination of af latoxin. The test portion Is extracted with methanol- water (7 + 3), filtered, diluted to ⦟30% methanol with water, and applied to the affinity column. The column Is washed with water and the concentrated aflatoxins are eluted with methanol. Total aflatoxins are determined by solution fluorometry with bromine (SFB), and Individual toxins are determined by reverse-phase liquid chromatography with postcolumn derlvatizatlon with Iodine (PCD). Corn naturally contaminated with aflatoxins, and peanuts, peanut butter, and corn containing added aflatoxins ( B1:B2:G1G2 = 7:1:3:1) were sent to 24 collaborators In the United States, France, Canada, and the Republic of South Africa. Twelve collaborators used the SFB method, 9 used the PCD method, and 3 used both SFB and PCD methods. Twenty collaborators completed the study (10 used the SFB method, 7 used the PCD method, and 3 used both SFB and PCD methods). Test portions were spiked at 10, 20, and 30 ng/g. For SFB analyses, recoveries of total aflatoxins were 123,105, and 107%, respectively; the relative standard deviation for repeatability (RSDr) ranged from 11.75 to 16.57%, and the relative standard deviation for reproducibility (RSDR) ranged from 10.97 to 33.09%. For PCD analyses, recoveries were 81, 81, and 83%, respectively; the RSDr ranged from 5.20 to 17.22%, and the RSDR ranged from 4.68 to 50.77%. The RSDr for aflatoxins B1, and G1 for spiked test portions ranged from 5.45 to 23.55%, and the RSDR ranged from 4.21 to 57.28%. The RSDr and RSDR for aflatoxins B2 and G2 were higher because of the small amounts added. Analyses by both SFB and PCD methods showed acceptable within-laboratory and betweenlaboratories precision. The method has been adopted official first action by AOAC as an AOAC-IUPAC method.


1994 ◽  
Vol 77 (3) ◽  
pp. 672-674 ◽  
Author(s):  
Paul R Beuaars ◽  
Remmelt Van Dijk ◽  
Arie Brands

Abstract A collaborative study of the determination of p-tolu-enesulfonamide (p-TSA) in ice cream by a combination of continuous flow and on-line liquid chromatography was conducted. Seven ice cream samples containing 0-6.35 mg p-TSA/kg at 4 levels (1 blank and 3 pairs of split level samples) were analyzed by 11 laboratories. For all samples analyzed, the repeatability relative standard deviation varied from 2.08 to 3.67%, whereas the reproducibility relative standard deviation ranged from 7.79 to 11.68%. The average p-TSA values for the split levels 1,2, and 3 were 0.55,1.02, and 4.44 mg p-TSA/kg, respectively, with mean recoveries ranging from 76 to 79% (overall recovery range for all levels, 63-101 %). No false positive results were reported for the blank sample, and no interference was encountered by the presence of vanillin in samples. The method has been adopted first action by AOAC INTERNATIONAL.


2001 ◽  
Vol 84 (2) ◽  
pp. 444-450 ◽  
Author(s):  
A Catherine Entwisle ◽  
Alison C Williams ◽  
Peter J Mann ◽  
Joanne Russell ◽  
Philip T Slack ◽  
...  

Abstract A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup. The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits. The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min. The extract was filtered, centrifuged, and then cleaned up on a phenyl silane column before being eluted from the washed column with methanol–water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent. After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection. Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and spiking solutions, were sent to 15 laboratories in 13 different European countries. Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low level of determination for ochratoxin A in roasted coffee.


2003 ◽  
Vol 86 (4) ◽  
pp. 685-693 ◽  
Author(s):  
Guo-Fang Pang ◽  
Yan-Zhong Cao ◽  
Chun-Lin Fan ◽  
Jin-Jie Zhang ◽  
Xue-Min Li ◽  
...  

Abstract Eighteen laboratories participated in a collaborative study on the determination of clopidol residues in chicken muscle tissues by liquid chromatography. Of these, results from 16 laboratories which rigorously followed the method were subjected to statistical analysis. The method performance was assessed by all participants using 14 samples of chicken muscle fortified at concentrations ranging from 0.1 to 5.0 mg/kg. In addition, 9 participants each reported results for 6 clopidol-incurred samples in chicken muscle. Test portions were extracted with acetonitrile, and the extracts were purified with alumina and anion exchange resin solid-phase extraction cartridges in sequence. Clopidol was separated by reversed-phase liquid chromatography and quantified at 270 nm. Average recoveries ranged from 81.8 to 85.4%, reproducibility relative standard deviation (RSDR) ranged from 11.9 to 22.6%, and repeatability relative standard deviation (RSDr) ranged from 9.9 to 15.1%. For clopidol-incurred samples at concentrations of 0.100–0.687 mg/kg, the mean determination value range was 0.099–0.659 mg/kg; RSDR was 12.6–19.8%, RSDr was 3.1–8.5%; and HORRAT values were 0.7–1.1. The accuracy and precision of the method are in conformity with the requirements specified by AOAC INTERNATIONAL. The method was adopted Official First Action in April 2003.


2001 ◽  
Vol 84 (4) ◽  
pp. 1116-1124 ◽  
Author(s):  
Joerg Stroka ◽  
Elke Anklam ◽  
Urban Joerissen ◽  
John Gilbert ◽  
A Barmark ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol–water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and 5 particpants used the Kobra cell. There was no evidence of method performance depending on the derivatization method used. The method showed acceptable within- and between-laboratory precision for baby food matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1.


2001 ◽  
Vol 84 (2) ◽  
pp. 437-443 ◽  
Author(s):  
Sylviane Dragacci ◽  
Frederic Grosso ◽  
John Gilbert ◽  
M Agnedal ◽  
L Hyndrick ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.


2005 ◽  
Vol 88 (6) ◽  
pp. 1733-1740 ◽  
Author(s):  
Susan J MacDonald ◽  
Sharron Anderson ◽  
Paul Brereton ◽  
Roger Wood ◽  
Andrew Damant ◽  
...  

Abstract An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an affinity column cleanup liquid chromatography (LC) method for the determination of zearalenone (ZON) in a variety of cereals and cereal products at proposed European regulatory limits. The test portion is extracted with acetonitrile:water. The sample extract is filtered, diluted, and applied to an affinity column. The column is washed, and ZON is eluted with acetonitrile. ZON is quantified by reversed-phase LC with fluorescence detection. Barley, wheat and maize flours, polenta, and a maize-based baby food naturally contaminated, spiked, and blank (very low level) were sent to 28 collaborators in 9 European countries and 1 collaborator in New Zealand. Participants were asked to spike test portions of all samples at a ZON concentration equivalent to 100 μg/kg. Average recoveries ranged from 91–111%. Based on results for 4 artificially contaminated samples (blind duplicates) and 1 naturally contaminated sample (blind duplicate), the relative standard deviation for repeatability (RSDr) ranged from 6.9–35.8%, and the relative standard deviation for reproducibility (RSDR) ranged from 16.4–38.2%. The method showed acceptable within- and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values <1.7.


2000 ◽  
Vol 83 (2) ◽  
pp. 320-340 ◽  
Author(s):  
Joerg Stroka ◽  
Elke Anklam ◽  
Urban Jörissen ◽  
John Gilbert ◽  
Anna Barmark ◽  
...  

Abstract A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 and total aflatoxins at European regulatory limits. The test portion is extracted with methanol–water (8 + 2) for dried figs and paprika, and with methanol–water (8 + 2) plus hexane (or cyclohexane) for peanut butter and pistachios. The sample extract is filtered, diluted with phosphate buffer saline, and applied to an immunoaffinity column. The column is washed with water and the aflatoxins are eluted with methanol. Aflatoxins are quantitated by reversed-phase LC with post-column derivatization (PCD) involving bromination. PCD is achieved with either an electrochemical cell (Kobra cell) and addition of bromide to the mobile phase or pyridinium hydrobromide perbromide. Determination is by fluorescence. Peanut butter, pistachio paste, dried fig paste, and paprika powder samples, both naturally contaminated with aflatoxins and containing added aflatoxins, were sent to 16 collaborators in 16 European countries. Test portions of samples were spiked at levels of 2.4 and 9.6 ng/g for total aflatoxins which included 1.0 and 4.0 ng/g aflatoxin B1, respectively. Recoveries for total aflatoxins ranged from 71 to 92% with corresponding recoveries for aflatoxin B1 of 82 to 109%. Based on results for spiked samples (blind duplicates at 2 levels) as well as naturally contaminated samples (blind duplicates at 4 levels, including blank), the relative standard deviation for repeatability ranged from 4.6 to 23.3% for total aflatoxins and from 3.1 to 20.0% for aflatoxin B1. The relative standard deviation for reproducibility ranged from 14.1 to 34.2% for total aflatoxins, and from 9.1 to 32.2% for aflatoxin B1. The method showed acceptable within-laboratory and between-laboratory precision for all 4 matrixes, as evidenced by HORRAT values <1, at the low levels of determination for both total aflatoxins and aflatoxin B1.