scholarly journals Multiresidue Chromatographic Method for the Determination of Macrolide Residues in Muscle by High-Performance Liquid Chromatography with UV Detection

1999 ◽  
Vol 82 (5) ◽  
pp. 1046-1053 ◽  
Author(s):  
Murielle Juhel-Gaugain ◽  
Béatrice Anger ◽  
Michel Laurentie

Abstract A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 × 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from ½ the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 μg/kg for tilmicosin and tylosin, 30 μg/kg for spiramycin, and 25 μg/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.

Author(s):  
Ha Tran Nguyen ◽  
Thuy Linh Hoang Thi ◽  
Binh Vu Ngan ◽  
Thanh Nhai Nguyen Thi ◽  
Toan Phi Van ◽  
...  

Smilax glabra rhizoma (SGR) has been used in traditional medicine remedies for the treatment of joint pain and inflammation, and recently, has been presented in dietary supplements for supporting arthritis and gout treatment. In the 5th Vietnamese Pharmacopoeia, astilbin was chosen as a chemical marker for the quality control of Smilax glabra as herbal medicine. A high performance liquid chromatographic (HPLC) method was developed for the qualitative and quantitative determination of astilbin in dietary supplements containing Smilax glabra. Ultrasonic extraction with 60% methanol was used for astilbin extraction from herbal products. HPLC analysis was performed with a C18 column and a mobile phase consisting of methanol and water in gradient mode, with UV detection at 291 nm. The method was validated according to AOAC International’s requirements with high specificity and precision.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


Sign in / Sign up

Export Citation Format

Share Document