scholarly journals Determination of Dyclonine Hydrochloride by a HPLC Method and Camphor and Menthol by a GC Method in Compound Lotion

2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.

2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Xiaojun Shang ◽  
Suying Ma ◽  
Zheshen Li

A rapid, sensitive, and reproducible reverse phase high performance liquid chromatographic (RP-HPLC) method with UV detector for the determination of nimodipine in sustained release tablets was developed. The method involved using a SinoChoom ODS-BP C18reversed phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of methanol-acetonitrile-water (35 : 38 : 27, v/v). The flow rate is 1.0 mL/min, the UV detector was operated at 237 nm, and the column was maintained at 25°C. The method was validated according to official compendia guidelines. The calibration curve of nimodipine for RP-HPLC method was linear over the range of 10–100 μg/mL. The retention time was found at 7.50 min for nimodipine. The variation for interday and intraday assay was found to be less than 0.72%. The proposed RP-HPLC was proved to be suitable for the determination of nimodipine in sustained release tablets.


2011 ◽  
Vol 47 (2) ◽  
pp. 261-268 ◽  
Author(s):  
Elisabete de Almeida Barbosa Antunes ◽  
Felipe Rebello Lourenço ◽  
Terezinha de Jesus Andreoli Pinto

A high-performance liquid chromatographic method employing pre-column derivatization with o-phthalaldehyde (OPA) and 2-mercaptoacetic acid was developed for the determination of apramycin, an aminoglycoside antibiotic used in veterinary medicine, in the oral soluble powder form. The chromatographic separation was done by ion-pair HPLC using a C18 reversed-phase column, Synergy Hydro (150 mm x 4.6 mm x 4 µm) and mobile phase composed of 0.005 mol/L sodium octanosulfonate in a mixture of acetonitrile: water: acetic acid (45:55:2) (v/v/v) with a flow rate of 1.0 mL/min; the UV detector was operated at 332 nm. The developed method was validated according to official compendia guidelines, having demonstrated robustness, selectivity and linearity for the concentration range of 0.02 to 0.05 mg/mL, precision (with RSD < 2.0% both for intra and inter-day precision) accuracy (average recuperation of 99.33%) and detectivity (quantification and detection limits of 0.08 and 0.02 µg/mL, respectively). Three batches of commercial apramycin oral soluble powder were analyzed by both the proposed method and the official microbiological method, where all the results obtained were in the acceptable range (95% to 105% of labeled value of apramycin). Both methods were statistically compared by the t test, which yielded no significant differences (α = 0.05) thereby confirming the equivalence of the methods.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (11) ◽  
pp. 46-50
Author(s):  
Z. G Khan ◽  
◽  
S. S. Patil ◽  
P. K. Deshmukh ◽  
P. O. Patil

Novel, isocratic reversed phase high performance liquid chromatography method was developed and validated for the determination of enzalutamide (EZA) in bulk drug and pharmaceutical formulation. Efficient separation was achieved on PrincetonSPHER C18 100A, 5μ (250×4.6 mm) under the isocratic mode of elution using acetonitrile: water (80:20) % V/V as a mobile phase pumped in to the column at flow rate 1.0 mL/min. The effluent was monitored at 237.0 nm using UV detector. EZA was eluted in the given mobile phase at retention time (tR) of 3.2 minutes. The standard calibration curve was linear over the concentration range 10 - 60 μg/mL with correlation coefficient 0.997. The method was validated for accuracy, precision, sensitivity, robustness, ruggedness and all the resulting data treated statistically. The system suitability parameters like retention time, theoretical plates, tailing factor, capacity factor were found within the limit.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


2008 ◽  
Vol 91 (4) ◽  
pp. 739-743 ◽  
Author(s):  
Andréia de Haro Moreno ◽  
Hérida Regina Nunes Salgado

Abstract A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanolwater (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 g/mL. The values for interday and intraday precision (relative standard deviation) were &lt;1. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


1988 ◽  
Vol 34 (12) ◽  
pp. 2502-2503 ◽  
Author(s):  
P A Hynning ◽  
P Anderson ◽  
U Bondesson ◽  
L O Boréus

Abstract A high-performance liquid chromatographic (HPLC) method for determining verapamil and norverapamil in plasma is presented and compared with gas chromatography/mass spectrometry (GC-MS). The plasma samples were extracted at alkaline pH with hexane containing 2-butanol (20 mL/L) and then back-extracted into phosphate buffer (0.1 mol/L, pH 3.0). For chromatography we used a reversed-phase column (Supelcosil LC-18 DB) with a mobile phase of the phosphate buffer and acetonitrile (70/30 by vol). Fluorescence detection was used (excitation at 203 nm, emission at 320 nm). Overall analytical recovery was 85%. Standard curves were linear from 1 to 1000 micrograms/L. The detection limit was 1 microgram/L. The assays are accurate and precise. We found no interferences by those substances tested. Results by HPLC and GC-MS agreed well (r = 0.99) for both verapamil and norverapamil determinations.


1988 ◽  
Vol 34 (9) ◽  
pp. 1897-1899 ◽  
Author(s):  
M H Cheng ◽  
W Y Huang ◽  
A I Lipsey

Abstract This high-performance liquid-chromatographic (HPLC) method for simultaneous determination of prednisone and its metabolite, prednisolone, in plasma is a modification of the method of Frey et al. (Clin Chem 1979;25:1944-7). Heparinized plasma (1.0 mL) with 0.1 mL of internal standard solution (11-deoxy-17-hydroxycorticosterone, 2 mg/L) is extracted with 7.0 mL of dichloromethane, then washed sequentially with 0.1 mol/L HCl, 0.1 mol/L NaOH, and deionized water, 2.0 mL each. The extract is evaporated and the residue reconstituted with 75 microL of mobile phase, methanol/H2O (40/60 by vol). Thirty microliters of this is injected onto a reversed-phase C6 column, which is eluted at 1.4 mL/min. Analytical recoveries of prednisone and prednisolone were 94-98% and 102-106%, respectively. Day-to-day precision (CV) was 3.8% for prednisone, 6.1% for prednisolone. We encountered no interference from the 21 other steroids and 25 drugs tested. This method is simple, accurate, and precise.


2011 ◽  
Vol 8 (4) ◽  
pp. 1958-1964 ◽  
Author(s):  
H. R. Prajapati ◽  
P. N. Raveshiya ◽  
J. M. Prajapati

A reversed phase high performance liquid chromatographic (RP–HPLC) method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm) using methanol: 50 mM KH2PO2buffer (PH adjusted to 6.8 with 0.1 M NaOH), 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.


2008 ◽  
Vol 73 (6) ◽  
pp. 665-671 ◽  
Author(s):  
Snezana Mitic ◽  
Gordana Miletic ◽  
Danijela Kostic ◽  
Daniela Naskovic-Ðokic ◽  
Biljana Arsic ◽  
...  

An accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantification of doxycycline hyclate in pharmaceutical samples has been developed and validated. The drug and the standard were eluted from a Lichrosorb RP-8 (250 mm x 4.6 mm, 10 mm particle size) at 20?C with a mobile phase consisting of methanol, acetonitrile and 0.010 M aqueous solution of oxalic acid (2:3:5, v/v/v). The flow rate was 1.25 ml min-1. A UV detector set at 350 nm was used to monitor the effluent. Each analysis required no longer than 4 min. The limits of detection and quantification were 1.15 and 3.84 ?g ml-1, respectively. Recoveries for different concentrations ranged from 99.58 to 101.93%.