scholarly journals Determination of Cefdinir by a Stability-Indicating Liquid Chromatographic Method

2005 ◽  
Vol 88 (6) ◽  
pp. 1661-1665 ◽  
Author(s):  
Tushar N Mehta ◽  
Gunta Subbaiah ◽  
Kilambi Pundarikakshudu

Abstract A simple, fast, specific, stability-indicating, and precise reversed-phase liquid chromatographic method was developed for the determination of Cefdinir in its different dosage forms, i.e., capsules and suspensions. The method was developed and optimized by analyzing the placebo preparation, formulations, and degraded samples of the drug substance according to the International Conference on Harmonization. The proposed method can successfully separate the drug from degradation products formed under stress conditions along with pharmaceutical ingredients such as preservatives. The developed method was used successfully to determine Cefdinir in capsules and Insta-use suspensions. The developed method was found to be linear for a concentration range of 6–14 μg/mL. Average recoveries obtained with the method were 99.3 ± 0.4 and 99.6 ± 0.4% for Insta-use suspensions and capsules, respectively. The method was shown to be specific, precise, and robust.

1992 ◽  
Vol 75 (1) ◽  
pp. 62-65 ◽  
Author(s):  
R Khazanchi ◽  
S Walia ◽  
S K Handa

Abstract A reversed-phase liquid chromatographic method has been developed for the determination of fenamiphos and the metabolites fenamiphos sulfoxide, fenamiphos sulfone, 3-methyl-4-(methylthlo)- phenol, and 3-methyl-4-(methylsulflnyl)phenol. Trace quantities of the nematlclde and Its metabolites In soil can be determined simultaneously. The limit of detection of the method was 5 ppm. Recoveries of fenamiphos and Its degradation products at fortification levels of 25,50, and 100 ppm ranged from 99.2 to 100.8%. Standard deviations ranged from 0.29 to 0.70 ppm.


1995 ◽  
Vol 78 (5) ◽  
pp. 1131-1133
Author(s):  
Alan R Hanks

Abstract A liquid chromatographic method for determination of dithianon in technical products and formulations was evaluated by 22 laboratories participating in a collaborative study. Data received from 19 laboratories were used in the statistical analysis. The study included 3 technical grade materials, 1 suspension concentrate, and 1 wettable powder. Dithianon is determined by reversed-phase liquid chromatography on a C18 column with a mobile phase of acetonitrile and water. Detection at 254 nm with peak area measurements is used with an external standard for quantitation of dithianon. The liquid chromatographic method for determination of dithianon in technical products and formulations has been adopted first action by AOAC INTERNATIONAL.


Sign in / Sign up

Export Citation Format

Share Document