Subtemporal craniectomy and elevation of shunt valve opening pressure in the management of small ventricle-induced cerebrospinal fluid shunt dysfunction

Neurosurgery ◽  
1982 ◽  
Vol 10 (6 Pt 1) ◽  
pp. 698???703
Author(s):  
J W Walsh ◽  
H E James
2016 ◽  
Vol 124 (2) ◽  
pp. 342-349 ◽  
Author(s):  
Laurent Sakka ◽  
Alexandre Chomicki ◽  
Jean Gabrillargues ◽  
Toufic Khalil ◽  
Jean Chazal ◽  
...  

OBJECT Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. METHODS Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21–87 years (mean age 64.3 years), and the range of the follow-up period was 1–3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3–6 months, 7–15 months, 16–24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. RESULTS In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. CONCLUSIONS Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors’ diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.


2012 ◽  
Vol 9 (2) ◽  
pp. 191-197 ◽  
Author(s):  
Joseph T. Cheatle ◽  
Alexis N. Bowder ◽  
Sandeep K. Agrawal ◽  
Michael D. Sather ◽  
Leslie C. Hellbusch

Object Cerebrospinal fluid shunt systems malfunction for a multitude of reasons, including malpostitioning, obstruction of the ventricular or distal catheter, obstruction of the shunt valve, and catheter disruptions or disconnections. The goal of this study was to examine the hydrodynamic resistance and flow in new and explanted catheters and also in catheters with 1 or 2 straight connectors. Methods Explanted catheters of multiple lengths, 2-piece catheters, 3-piece catheters, and new catheters were attached to a proximal and distal manometer. A flask with artificial CSF attached to the proximal end provided flow. The flow was allowed to stabilize over 1 hour; then the change in pressure between the proximal and distal end of the catheter was measured. Results The resistance to flow was calculated for new, never-implanted catheters and compared with the resistance of explanted distal shunt catheters. The resistance of the new catheters was examined after the addition of 1 and 2 straight connectors. Explanted catheters exhibited a slight increase in the resistance to flow of artificial CSF compared with new catheters. Two-piece and 3-piece catheters had a significant increase in resistance to flow compared with new catheters. For all catheters, resistance to flow increased as length increased (new, p = 0.01; explanted, p = 0.009; 1 connector, p = 0.01; 2 connectors, p = 0.03). In this paper, effective diameter is defined as the available cross-sectional area of catheter contacted by the artificial CSF. For new and explanted catheters, a decrease in the effective diameter of the catheter was associated with an increase in the resistance to flow of artificial CSF (new, p = 0.1083; explanted, p = 0.0091). However, after the addition of 1 or 2 connectors, an inverse trend was observed: resistance to flow increased with effective diameter. Conclusions There appears to be some increase in resistance of CSF shunt catheters as they age, altering flow dynamics. In addition, the use of straight connectors within a CSF shunt system increases the resistance to flow of artificial CSF within the shunt system. The increase in resistance appears to be related to the duration of implantation and the length of the catheter and inversely related to the diameter of the catheter. This increase in resistance may be related to sterile shunt malfunction. The addition of straight connectors is associated with a significant increase in resistance in comparison with catheters without connectors (p = 0.005).


2018 ◽  
Vol 14 ◽  
pp. 183-185
Author(s):  
Kota Sato ◽  
Toru Yamashita ◽  
Keichiro Tsunoda ◽  
Mami Takemoto ◽  
Nozomi Hishikawa ◽  
...  

2021 ◽  
Vol 1 ◽  
pp. 100499
Author(s):  
B. Sommer ◽  
I. Konietzko ◽  
M.N. Bonk ◽  
B. Hackanson ◽  
M. Trepel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document