Clinical Long-Term Results of Anterior Discectomy Without Interbody Fusion for Cervical Disc Disease

Spine ◽  
1991 ◽  
Vol 16 (3) ◽  
pp. 272-279 ◽  
Author(s):  
ISAO YAMAMOTO ◽  
AKIRAIKEDA ◽  
NAOKI SHIBUYA ◽  
RYUICHI TSUGANE ◽  
OSAMU SATO
2004 ◽  
Vol 17 (3) ◽  
pp. 155-159 ◽  
Author(s):  
Praveen V. Mummaneni ◽  
Regis W. Haid

✓ In the past 50 years tremendous advances have been made in the treatment of cervical disc disease with cervical fusion. Fusion rates have surpassed 95% after application of anterior cervical implants. Adjacent-segment degeneration, however, has plagued the long-term clinical success of cervical fusion. Cervical arthroplasty has been introduced to maintain cervical motion and potentially avoid or minimize adjacent-segment degeneration. If cervical arthroplasty is successful, the long-term results of surgery for cervical disc disease may improve; however, there are associated drawbacks that must be overcome. Implant wear, fatigue, and failure have been reported in cases of large-joint arthroplasty, and research is underway to limit these problems in cervical arthroplasty. In this article the authors trace the evolution of cervical fusion and the new technique of cervical arthroplasty. The nomenclature of cervical arthroplasty will also be introduced.


1994 ◽  
Vol 3 (1) ◽  
pp. 45-51 ◽  
Author(s):  
Takashi Yuasa ◽  
Yuji Nikaido ◽  
Kiyoshi Nagata ◽  
Yeohg-jin Kim ◽  
Kenta Fujimoto ◽  
...  

2004 ◽  
Vol 1 (2) ◽  
pp. 155-159 ◽  
Author(s):  
Praveen V. Mummaneni ◽  
Regis W. Haid

✓ In the past 50 years tremendous advances have been made in the treatment of cervical disc disease with cervical fusion. Fusion rates have surpassed 95% after application of anterior cervical implants. Adjacent-segment degeneration, however, has plagued the long-term clinical success of cervical fusion. Cervical arthroplasty has been introduced to maintain cervical motion and potentially avoid or minimize adjacent-segment degeneration. If cervical arthroplasty is successful, the long-term results of surgery for cervical disc disease may improve; however, there are associated drawbacks that must be overcome. Implant wear, fatigue, and failure have been reported in cases of large-joint arthroplasty, and research is underway to limit these problems in cervical arthroplasty. In this article the authors trace the evolution of cervical fusion and the new technique of cervical arthroplasty. The nomenclature of cervical arthroplasty will also be introduced.


1986 ◽  
Vol 26 (6) ◽  
pp. 481-486 ◽  
Author(s):  
Toyohiko ISU ◽  
Hiroshi ABE ◽  
Yoshinobu IWASAKI ◽  
Kenji MITSUMORI ◽  
Mitsuo TSURU ◽  
...  

2005 ◽  
Vol 3 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Jyi-Feng Chen ◽  
Chieh-Tsai Wu ◽  
Sai-Cheung Lee ◽  
Shih-Tseng Lee

Object. Polymethylmethacrylate (PMMA) bone cement has been used as a spacer in the treatment of patients with cervical disc disease with good long-term outcomes, but solid bone fusion has not been demonstrated in all cases. To achieve cervical interbody fusion, the authors designed a modified PMMA cervical cage that they filled with spongy bone for the treatment of single-level cervical disc herniation. Methods. Sixty-three patients underwent anterior cervical microdiscectomy and implantation of a PMMA cervical cage filled with autograft cancellous bone and were followed for a minimum of 2 years. The fusion rates were 90.5 and 100% at the 6- and 12-month follow-up examinations, respectively. The mean intervertebral disc height gain was 3.4 ± 1.9 mm when preoperative and 24-month postoperative values were compared. Neck pain, measured using the Huskissan visual analog scale (0 mm, no pain; 100 mm, worst possible pain), decreased from 71 ± 13 mm at preoperative baseline to 28 ± 17 at 6, 23 ± 19 at 12, and 31 ± 19 mm at 24 months. Based on the same scale, radicular pain decreased from 83 ± 15 mm at preoperative baseline to 24 ± 11 at 6, 27 ± 13 at 12, and 22 ± 11 mm at 24 months. The self-rated clinical outcome was excellent in 45 (71.4%) and good in 18 (28.6%) of the 63 patients. Conclusions. The autograft cancellous bone—filled PMMA cage is safe and effective for cervical interbody fusion in the treatment of single-level cervical disc herniation and monoradiculopathy.


Sign in / Sign up

Export Citation Format

Share Document