Effect of Electroencephalography Spectral Edge Frequency (SEF) and Patient State Index (PSI)-Guided Propofol-Remifentanil Anesthesia on Delirium After Laparoscopic Surgery

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
E. Wang ◽  
Lu Wang ◽  
Chunyan Ye ◽  
Ning Luo ◽  
Yanrong Zhang ◽  
...  
2004 ◽  
Vol 21 (1) ◽  
pp. 6-12 ◽  
Author(s):  
G. Schneider ◽  
A. Mappes ◽  
T. Neissendorfer ◽  
M. Schabacker ◽  
H. Kuppe ◽  
...  

1998 ◽  
Vol 89 (Supplement) ◽  
pp. 930A ◽  
Author(s):  
Laverne D. Gugino ◽  
Robert J. Chabot ◽  
Leslie S. Prichep ◽  
E. Roy John

2002 ◽  
Vol 96 (Sup 2) ◽  
pp. A547
Author(s):  
Jun Tang ◽  
Hong Ma ◽  
Paul F. White ◽  
Scott Pearce ◽  
Ronald H. Wender

2020 ◽  
Author(s):  
Sang-Hwan Ji ◽  
Young-Eun Jang ◽  
Eun-Hee Kim ◽  
Ji-Hyun Lee ◽  
Jin-Tae Kim ◽  
...  

Abstract Background: Cortical electroencephalography (EEG)-based devices are used to monitor the depth of anesthesia. In this study, we compared the values of bispectral index (BIS) and patient state index (PSI) during sevoflurane anesthesia in children. The ability/accuracy of BIS and PSI to predict the maintenance and recovery state of anesthesia was evaluated based on prediction probability (Pk) values and the secondary outcomes were agreement and correlation of two monitors.Methods: Fifty children (3-12 years old) were enrolled and the patients received sevoflurane anesthesia with remifentanil. Before the induction of anesthesia, BIS and PSI sensors were simultaneously placed on the forehead, and data were collected until the end of anesthesia. Maintenance state was defined as the period following intubation until the cessation of sevoflurane, while recovery state was defined as the period following the cessation of sevoflurane until awake. The prediction probability (Pk), agreement or correlation of BIS and PSI in different anesthesia state were calculated.Results: Anesthesia reduced mean BIS and PSI values. Pk of BIS (95% Confidential Interval (CI) [0.78-0.91])) and PSI (95% CI [0.82-0.91]) for anesthesia were 0.85 and 0.87, respectively. Agreement was 0.79 for recovery state and 0.73 for maintenance state.Conclusions: Pk values were comparable for BIS and PSI. Agreement between BIS and PSI measurements in the same state was relatively good. Therefore, these monitors are appropriate for monitoring for different state of anesthesia in pediatric population.Trial Registry Number: Clinical Trials.gov NCT03792334.


2020 ◽  
Author(s):  
Sang-Hwan Ji ◽  
Young-Eun Jang ◽  
Eun-Hee Kim ◽  
Ji-Hyun Lee ◽  
Jin-Tae Kim ◽  
...  

Abstract Background: Cortical electroencephalography (EEG)-based devices are used to monitor the depth of anesthesia. In this study, we compared the values of bispectral index (BIS) and patient state index (PSI) during sevoflurane anesthesia in children. The ability/accuracy of BIS and PSI to predict the steady and recovery state of anesthesia was evaluated based on prediction probability (Pk) values and the secondary outcomes were agreement and correlation of two monitors. Methods: Fifty children (3-12 years old) were enrolled and the patients received sevoflurane anesthesia with remifentanil. Before the induction of anesthesia, BIS and PSI sensors were simultaneously placed on the forehead, and data were collected until the end of anesthesia. Steady state was defined as the period following intubation until the cessation of sevoflurane, while recovery state was defined as the period following the cessation of sevoflurane until awake. The prediction probability (Pk), agreement or correlation of BIS and PSI in different anesthesia state were calculated. Results: Anesthesia reduced mean BIS and PSI values. Pk of BIS (95% confidential interval (CI) [0.78-0.91])) and PSI (95% CI [0.82-0.91]) for anesthesia were 0.85 and 0.87, respectively. Agreement was 0.79 for recovery state and 0.73 for steady state. Conclusions: Pk values were comparable for BIS and PSI. Agreement between BIS and PSI measurements in the same state was relatively good. Therefore, these monitors are appropriate for monitoring for different state of anesthesia in pediatric population. Trial Registry Number: Clinical Trials.gov NCT03792334.


2019 ◽  
Vol 131 (6) ◽  
pp. 1223-1238 ◽  
Author(s):  
Merel H. Kuizenga ◽  
Pieter J. Colin ◽  
Koen M. E. M. Reyntjens ◽  
Daan J. Touw ◽  
Hasan Nalbat ◽  
...  

Abstract Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New Background The population pharmacodynamics of propofol and sevoflurane with or without opioids were compared using the endpoints no response to calling the person by name, tolerance to shake and shout, tolerance to tetanic stimulus, and two versions of a processed electroencephalographic measure, the Patient State Index (Patient State Index-1 and Patient State Index-2). Methods This is a reanalysis of previously published data. Volunteers received four anesthesia sessions, each with different drug combinations of propofol or sevoflurane, with or without remifentanil. Nonlinear mixed effects modeling was used to study the relationship between drug concentrations, clinical endpoints, and Patient State Index-1 and Patient State Index-2. Results The C50 values for no response to calling the person by name, tolerance to shake and shout, and tolerance to tetanic stimulation for propofol (µg · ml−1) and sevoflurane (vol %; relative standard error [%]) were 1.62 (7.00)/0.64 (4.20), 1.85 (6.20)/0.90 (5.00), and 2.82 (15.5)/0.91 (10.0), respectively. The C50 values for Patient State Index-1 and Patient State Index-2 were 1.63 µg · ml−1 (3.7) and 1.22 vol % (3.1) for propofol and sevoflurane. Only for sevoflurane was a significant difference found in the pharmacodynamic model for Patient State Index-2 compared with Patient State Index-1. The pharmacodynamic models for Patient State Index-1 and Patient State Index-2 as a predictor for no response to calling the person by name, tolerance to shake and shout, and tetanic stimulation were indistinguishable, with Patient State Index50 values for propofol and sevoflurane of 46.7 (5.1)/68 (3.0), 41.5 (4.1)/59.2 (3.6), and 29.5 (12.9)/61.1 (8.1), respectively. Post hoc C50 values for propofol and sevoflurane were perfectly correlated (correlation coefficient = 1) for no response to calling the person by name and tolerance to shake and shout. Post hoc C50 and Patient State Index50 values for propofol and sevoflurane for tolerance to tetanic stimulation were independent within an individual (correlation coefficient = 0). Conclusions The pharmacodynamics of propofol and sevoflurane were described on both population and individual levels using a clinical score and the Patient State Index. Patient State Index-2 has an improved performance at higher sevoflurane concentrations, and the relationship to probability of responsiveness depends on the drug used but is unaffected for Patient State Index-1 and Patient State Index-2.


2006 ◽  
Vol 23 (Supplement 37) ◽  
pp. 21
Author(s):  
M. Soehle ◽  
R. Ellerkmann ◽  
M. Kuech ◽  
M. Grube ◽  
S. Wirz ◽  
...  

2006 ◽  
Vol 20 (1) ◽  
pp. 121-128 ◽  
Author(s):  
David Drover ◽  
H.R. (Rick) Ortega

Sign in / Sign up

Export Citation Format

Share Document