Treatment of complicated pediatric femoral fractures with titanium elastic nail

2008 ◽  
Vol 17 (1) ◽  
pp. 7-10 ◽  
Author(s):  
Mehmet Cemalettin Aksoy ◽  
Omur Caglar ◽  
Mehmet Ayvaz ◽  
Muharrem Yazici ◽  
Ahmet Mumtaz Alpaslan
2021 ◽  
Vol 12 (3) ◽  
pp. 81-87
Author(s):  
Sujay K Mahadik ◽  
Sasha Martyres ◽  
Mrutyunjay S Gaonkar ◽  
Anish W Isapure ◽  
Shrikant B Deshpande

Background: Distal femur fractures are generally due to high velocity trauma particularly form road traffic accidents and fall from height. The treatment of distal femur fractures has evolved from conservative to operative to fixation of both lateral and medial columns of femur. Aims and Objective:  The aim of this study was to evaluate the functional outcome of operated cases of comminuted fracture of lower end of femur fixed with locking compression plate laterally and augmented with titanium elastic nail system medially. Materials and Methods: The present study was a prospective study carried out in Bharati Vidyapeeth Medical College and Hospital, Sangli after approval from institutional ethical committee. In this study, 20 patients with communited fracture of lower end of femur were included on the basis of a predefined inclusion and exclusion criteria. Detailed history was taken and clinical examination was done in all cases. After preanesthetic evaluation and relevant investigations patients were treated by reduction (close or open) and fixation was done by locking compression plate laterally and augmented with titanium elastic nail system medially. Patients were followed up at 6, 10 and 14 weeks for functional outcome by Neer’s scoring system and degree of flexion at knee joint. Results: Out of 20 studied cases there were 16 (80%) males and 4 (20%) were females with a M:F ratio of 4:1. The mean age of male patients was found to be 42.81+/-14.79 whereas mean age of female patients was 40.5 +/- 14.36. The mean age of male and female patients was found to be comparable with no statistically significant difference (P=0.78). Most of the patient were diagnosed with the fracture of AO TYPE C3 (7 cases), followed by AO TYPE C1 (4 cases). Full weight bearing was achieved in 8 (40%) patients within 18 weeks whereas remaining 12 (60%) patients required more than 20 weeks for full weight bearing. 14 (70%) patients had excellent outcome whereas, Good, Fair and poor outcomes were seen in 4 (20%), 1 (5%) and 1 (5%) patient. On one-way ANOVA analysis, showed that the flexion was significantly higher in 12 weeks as that of the 6 weeks (P =<0.0001). Further the flexion was significantly higher in 24 weeks as that of the 6 and 12 weeks (P =<0.0001). Conclusion: Our study found that locking compression plating laterally augmented with titanium elastic nail system medially for comminuted distal femoral fractures is a good fixation system and provides good angular stability.


2020 ◽  
pp. 221049172097518
Author(s):  
Vineet Thomas Abraham ◽  
Chandrasekaran Marimuthu

Purpose: Fixation of displaced midshaft clavicle is well known to decrease nonunion, malunion and shoulder disability as compared to nonoperative treatment. This study was done to compare the clinical and functional outcome of group 1 clavicle fractures treated with anatomic locking plates (ALP) versus Titanium elastic nail (TEN). Methods: We studied patients presenting with displaced midshaft clavicle fractures treated with ALP or TEN. The study period was from Jan 2013 to Dec 2016. Patients were reviewed and at each visit clinical and radiological progress of union was noted, complications if any were noted, functional assessment was done using the quick Dash score and Constant Murley score. Results: A total of 116 patients met our inclusion criteria. 62 patients were treated with TEN and 54 with ALP. Bony union was achieved at an average of 11.8 weeks in the TENS group and 12.8 weeks in the ALP group post operatively and this was found to be significant. The mean postoperative Constant Murley score in the ALP and the TEN groups were 92.8 (range 80–97), and 93.7 (82–97) respectively. The mean postoperative quick dash score in the ALP and TEN groups were 2.48(range from 0 to 6.8) and 2.1 (range 0–9.1) respectively. Conclusion: Both Anatomical locking plate and TEN are good options for the treatment of non-comminuted mid clavicular fractures as they have a similar functional outcome. TEN nail insertion has the advantage of being minimally invasive, having a faster union time and may be recommended in midshaft clavicle fractures without comminution.


2016 ◽  
Vol 07 (02) ◽  
pp. 49-53
Author(s):  
Hrushikesh Saraf ◽  
Sarang Kasture

Medicina ◽  
2020 ◽  
Vol 56 (2) ◽  
pp. 79
Author(s):  
Ovidiu Adam ◽  
Vlad Laurentiu David ◽  
Florin George Horhat ◽  
Eugen Sorin Boia

Background and objectives: There are various methods in the management of forearm fractures in children. Elastic stable intramedullary nailing using Titanium Elastic Nail (TEN) is nowadays employed in diaphysis fractures of children, with clear benefits over other treatment options. However, in the case of TEN versus other treatment methods of forearm fractures in children, cost is an important issue. This report will focus on the cost assessment of using TEN versus other therapeutic means in the treatment of forearm fractures in children. Materials and Methods: We performed a retrospective longitudinal study of 173 consecutive patients with forearm fractures treated in a single institution during 2017. We calculated the cost for each patient by summing up direct costs plus indirect costs, calculated at an aggregate level. Hospital income data were extracted from the Diagnosis Related Groups database. Results: A total of 173 patients with forearm fractures were treated, 44 using TEN, 86 using K-wire, and 46 using closed reduction and cast. There were 66 radius fractures, 1 ulna fracture, and 106 that were both radius and ulna fractures. Mean treatment cost were $632.76 for TEN, $499.50 for K-wire, and $451.30 for closed reduction and cast. Costs for TEN were higher than for K-wire insertion (p = 0.00) and higher than closed reduction and cast ($182.42; p = 0.00). Reimbursement per patient was higher with TEN versus K-wire patients; $497.88 vs. $364.64 /patient (p = 0.00), and higher than for patients treated with closed reduction and cast (p = 0.00). Conclusions: The treatment of upper extremity fractures using TEN was more expensive than the other methods. In Romania, because the reimbursement for TEN is higher as well, there are no differences in the financial burden when treating forearm fractures with TEN versus K-wire. Non-surgical treatment has the lowest cost but also the lowest reimbursement.


2017 ◽  
Vol 13 (6) ◽  
pp. 2997-3002 ◽  
Author(s):  
Kaiying Shen ◽  
Yunlan Xu ◽  
Dan Cao ◽  
Zhigang Wang ◽  
Haiqing Cai

Sign in / Sign up

Export Citation Format

Share Document