Comparison of Laryngeal Mask Airway Supreme and Laryngeal Mask Airway Proseal with respect to oropharyngeal leak pressure during laparoscopic cholecystectomy

2013 ◽  
Vol 30 (3) ◽  
pp. 119-123 ◽  
Author(s):  
José M. Beleña ◽  
Mónica Núñez ◽  
Diego Anta ◽  
Maria Carnero ◽  
José L. Gracia ◽  
...  
2002 ◽  
Vol 30 (5) ◽  
pp. 624-627 ◽  
Author(s):  
A. Howath ◽  
J. Brimacombe ◽  
C. Keller

We determined the success rates, cardiovascular responses and airway morbidity for gum-elastic bougie-guided insertion of the ProSeal™ laryngeal mask airway. One hundred anaesthetized, non-paralyzed adults (ASA 1–2, aged 18 to 80 years) were studied. The ProSeal LMA drainage tube was primed with a well-lubricated 16 French gauge gum-elastic bougie with the curved end proximal and the straight end protruding 30 cm beyond the drainage tube tip. The straight end of the gum-elastic bougie was inserted into the oesophagus under laryngoscopic guidance, the laryngoscope removed and the ProSeal LMA inserted using the standard insertion technique and the gum-elastic bougie as a guide. The following variables were recorded: ease of insertion, oropharyngeal leak pressure, ventilatory capability, ease of gastric tube insertion, blood staining on the bougie or LMA at removal, and postoperative airway morbidity. Haemodynamic data were recorded immediately pre-insertion and every minute for five minutes after insertion. Gum-elastic bougie and ProSeal LMA insertion was successful at the first attempt in all patients within 50 seconds. There were no significant increases in heart rate or blood pressure. Oropharyngeal leak pressure was 33 (17–40) cmH 2 O and ventilation was possible without leak in all patients at 9.5 ml.kg –1 tidal volume. There were no drainage tube or gastric air leaks. Gastric tube insertion was successful at the first attempt in all patients. Blood staining at removal was not detected on the gum-elastic bougie, but was detected in 3% of ProSeal LMAs. The incidence of sore throat, dysphagia and dysarthria was 21%, 9% and 1% respectively. We conclude that gum-elastic bougie-guided insertion of the ProSeal LMA has a high success rate and is associated with minimal haemodynamic change and a low incidence of trauma.


Author(s):  
Xiang Liu ◽  
Xiaona Tan ◽  
Qi Zhang ◽  
Li Qiao ◽  
Lei Shi

Abstract Objective An adequate intracuff pressure is important to ensure sufficient sealing function when using supraglottic airway devices to protect the airway from secretions and achieve adequate positive pressure ventilation. The aim of this study is to analyze a feasible and effective alternative Ambu AuraFlex intracuff pressure in child's laparoscopic surgery. Study Design Seventy-two children were included in this study. After insertion of the laryngeal mask airway AuraFlex, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 10, 30, and 60-cmH2O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, AuraFlex was maintained using the last intracuff pressure of the allocated sequence. Oropharyngeal leak pressure, peak airway pressure, the fiberoptic view, mucosal change, and complications were assessed at three intracuff pressures. Results The OLP at the intracuff pressure of 10 cmH2O was significantly lower than that of 30 cmH2O (2# 18.1 ± 1.5 vs. 19.5 ± 1.4 cmH2O, p = 0.001; 2.5# 17.7 ± 1.2 vs. 20.2 ± 1.4, p = 0.001) and 60 cmH2O (2# 18.1 ± 1.5 vs. 20.0 ± 1.3 cmH2O, p = 0.002; 2.5# 17.7 ± 1.2 vs. 20.8 ± 1.1, p = 0.003). Compared with the peak airway pressure in pre-and postpneumoperitoneum, the OLP was significantly higher. Subgroup analysis showed no differences in mucosal change and complications. Conclusion Intracuff pressures of 30 may be sufficient for the Ambu AuraFlex in child's laparoscopic surgery, and there may be no added benefit of an intracuff pressure of 60 cmH2O, as oropharyngeal leak pressures were similar.


Sign in / Sign up

Export Citation Format

Share Document