Short-Term In Vivo Preclinical Biocompatibility Evaluation of FW-II Axial Blood Pump in a Sheep Model

ASAIO Journal ◽  
2011 ◽  
Vol 57 (3) ◽  
pp. 177-182 ◽  
Author(s):  
Haibo Chen ◽  
Jianye Zhou ◽  
Hansong Sun ◽  
Yue Tang ◽  
Yan Zhang ◽  
...  
Keyword(s):  
2013 ◽  
Vol 32 (4) ◽  
pp. S148-S149
Author(s):  
N.R. Teman ◽  
D.S. Demos ◽  
B.S. Bryner ◽  
B. Faliks ◽  
E.M. Fracz ◽  
...  

2014 ◽  
Vol 98 (1) ◽  
pp. 97-102 ◽  
Author(s):  
Nicholas R. Teman ◽  
David S. Demos ◽  
Benjamin S. Bryner ◽  
Bradley Faliks ◽  
Emilia M. Jahangir ◽  
...  

2019 ◽  
Vol 130 ◽  
pp. 32-43 ◽  
Author(s):  
Elias Begas ◽  
Maria Bounitsi ◽  
Thomas Kilindris ◽  
Evangelos Kouvaras ◽  
Konstantinos Makaritsis ◽  
...  

Author(s):  
Daniel L. Villeneuve ◽  
Brett R. Blackwell ◽  
Jenna E. Cavallin ◽  
Wan‐Yun Cheng ◽  
David J. Feifarek ◽  
...  

2021 ◽  
Vol 12 (3) ◽  
pp. 44
Author(s):  
Leyla Hasandoost ◽  
Daniella Marx ◽  
Paul Zalzal ◽  
Oleg Safir ◽  
Mark Hurtig ◽  
...  

Poly(methyl methacrylate) (PMMA) is used to manage bone loss in revision total knee arthroplasty (rTKA). However, the application of PMMA has been associated with complications such as volumetric shrinkage, necrosis, wear debris, and loosening. Glass polyalkenoate cements (GPCs) have potential bone cementation applications. Unlike PMMA, GPC does not undergo volumetric shrinkage, adheres chemically to bone, and does not undergo an exothermic setting reaction. In this study, two different compositions of GPCs (GPCA and GPCB), based on the patented glass system SiO2-CaO-SrO-P2O5-Ta2O5, were investigated. Working and setting times, pH, ion release, compressive strength, and cytotoxicity of each composition were assessed, and based on the results of these tests, three sets of samples from GPCA were implanted into the distal femur and proximal tibia of three sheep (alongside PMMA as control). Clinical CT scans and micro-CT images obtained at 0, 6, and 12 weeks revealed the varied radiological responses of sheep bone to GPCA. One GPCA sample (implanted in the sheep for 12 weeks) was characterized with no bone resorption. Furthermore, a continuous bone–cement interface was observed in the CT images of this sample. The other implanted GPCA showed a thin radiolucent border at six weeks, indicating some bone resorption occurred. The third sample showed extensive bone resorption at both six and 12 weeks. Possible speculative factors that might be involved in the varied response can be: excessive Zn2+ ion release, low pH, mixing variability, and difficulty in inserting the samples into different parts of the sheep bone.


Author(s):  
Xiu‐Shi Zhang ◽  
En‐Hui Liu ◽  
Xin‐Yu Wang ◽  
Xin‐Xiang Zhou ◽  
Hong‐Xia Zhang ◽  
...  

1976 ◽  
Vol 156 (3) ◽  
pp. 585-592 ◽  
Author(s):  
P D Whitton ◽  
D A Hems

1. A total loss of capacity for net glycogen synthesis was observed in experiments with the perfused liver of starved adrenalectomized rats. 2. This lesion was corrected by insulin or cortisol in vivo (over 2-5h), but not by any agent tested in perfusion. 3. The activity of glycogen synthetase a, and its increase during perfusion, in the presence of glucose plus glucogenic substrates, were proportional to the rate of net glycogen accumulation. 4. This complete inherent loss of capacity for glycogen synthesis after adrenalectomy is greater than any defect in hepatic metabolism yet reported in this situation, and is not explicable by a decrease in the rate of gluconegenesis (which supports glycogen synthesis in the liver of starved rats). The short-term (2-5h) stimulatory effect of glucocorticoids in the intact animal, on hepatic glycogen deposition, may be mediated partly through insulin action, although neither insulin or cortisol appear to act directly on the liver to stimulate glycogen synthesis.