Effect of Le Fort I Maxillary Repositioning on Three-Dimensional Nasal Tip Rotation: A Comparative Study with Implication for the Asian Nose

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Rafael Denadai ◽  
Pang-Yun Chou ◽  
Chuan-Fong Yao ◽  
Ying-An Chen ◽  
Yi-Yu Lin ◽  
...  
2021 ◽  
pp. 103707
Author(s):  
Oliver da Costa Senior ◽  
Lukas Vaes ◽  
Delphine Mulier ◽  
Reinhilde Jacobs ◽  
Constantinus Politis ◽  
...  

1997 ◽  
Vol 34 (1) ◽  
pp. 36-45 ◽  
Author(s):  
Andrew M. Mccance ◽  
James P. Moss ◽  
W. Rick Fright ◽  
Alf D. Linney ◽  
David R. James

The three-dimensional, facial soft-tissue changes of 24 patients with various cleft types following transpalatal Le Fort I osteotomy were measured using laser scanning techniques, radial measurements, and a color millimetric scale. There was a varying degree of midface retrusion in the different cleft groups, and a very similar pattern of retrusion over the nasal complex. Each group of patients showed a varying degree of relapse postsurgically, but there was a failure in all the cleft groups to correct the lack of nasal projection.


2014 ◽  
Vol 43 (2) ◽  
pp. 197-203 ◽  
Author(s):  
B.F. Gaia ◽  
L.R. Pinheiro ◽  
O.S. Umetsubo ◽  
F.F. Costa ◽  
M.G.P. Cavalcanti

2021 ◽  
Author(s):  
Yiu Yan LEUNG ◽  
Jasper Ka Chai LEUNG ◽  
Alvin Tsz Choi LI ◽  
Nathan En Zuo TEO ◽  
Karen Pui Yan LEUNG ◽  
...  

Abstract The design and fabrication of three-dimensional (3D) -printed patient-specific implants (PSIs) for orthognathic surgery are customarily outsourced to commercial companies. We propose a protocol of designing PSIs and surgical guides by orthognathic surgeons-in-charge instead for wafer-less Le Fort I osteotomy. The aim of this prospective study was to evaluate the accuracy and post-operative complications of PSIs that are designed in-house for Le Fort I osteotomy. The post-operative cone beam computer tomography (CBCT) model of the maxilla was superimposed to the virtual surgical planning to compare the discrepancies of pre-determined landmarks, lines and principal axes between the two models. Twenty-five patients (12 males, 13 females) were included. The median linear deviations of the post-operative maxilla of the x, y and z axes were 0.74 mm, 0.75 mm and 0.72 mm, respectively. The deviations in the principal axes for pitch, yaw and roll were 1.40°, 0.90° and 0.60°, respectively. There were no post-operative complications related to the PSIs in the follow-up period. The 3D-printed PSIs designed in-house for wafer-less Le Fort I osteotomy are accurate and safe. Its clinical outcomes and accuracy are comparable to commercial PSIs for orthognathic surgery.


Author(s):  
F.B.D.J. Boos Lima ◽  
C.E.A. Dutra ◽  
V. Pereira-Filho ◽  
E. Hochuli-Vieira ◽  
S.M. Lima Junior

Sign in / Sign up

Export Citation Format

Share Document