Fibrin Glue Mesh Fixation in Hernia Repair

2007 ◽  
Vol 246 (5) ◽  
pp. 906-908 ◽  
Author(s):  
Bengt Novik
2013 ◽  
Vol 79 (11) ◽  
pp. 1177-1180 ◽  
Author(s):  
Nathaniel Stoikes ◽  
David Webb ◽  
Ben Powell ◽  
Guy Voeller

The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m2. Average mesh size was 14.5 cm 3 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.


2019 ◽  
Vol 6 (4) ◽  
pp. 1305
Author(s):  
Rajkumar Parameshwar Narayanakar ◽  
Kushal Kumar Talagavara Radhakrishna ◽  
Madhuri G. Naik

Background: Hernia is one of the oldest maladies known and suffered by humans. It has been known since ages and will be known for centuries to come as long as human beings prompt to stand and walk. Lichtenstein hernia repair is the most common procedure followed surgery but with some devastating complications such as chronic groin pain (CGP). The search for the most appropriate method to fix mesh and to reduce complications is still on and this study aims for the same.Methods: A comparative prospective study conducted in Department of General Surgery, Bangalore medical college & Research institute from November-2016 to May-2018. 100 patients falling into inclusion criteria were taken to study with randomization, 50 in each group (prolene vs Fibrin-glue). Postoperatively patient was assessed for complications, recovery time and Data collected was statistically analyzed using appropriate statistical test and p<0.05 was taken significant.Results: Most common age group presenting with hernia was from 41-50 years (29%) with M: F ration 5.6:1. Laterality being right: left: bilateral:: 58%: 36% :6% respectively. Type of hernia being Indirect: Direct:: 66%: 34% respectively. Duration of surgery, recovery to ADL and postoperative complications like seroma, chronic groin pain, foreign-body sensation was significantly less with fibrin glue compared to prolene group. Postoperative Haematoma, local numbness and recurrence were comparable and the difference in the result was statistically insignificant.Conclusions: Through our study from the above-mentioned benefits, it can be concluded that use of fibrin Glue in mesh fixation is a safe and acceptable method and can be used as a better alternative for prolene suture for mesh fixation in Liechtenstein’s hernioplasty.


2021 ◽  
Vol 11 (2) ◽  
pp. 56-58
Author(s):  
Vladimir Akimov ◽  
Dmitry Krikunov ◽  
Dmitry Parshin ◽  
Behruz Radzhabov ◽  
Vladimir Senko

The article is devoted to the evolution of fixation methods for synthetic mesh endoprostheses in surgery of inguinal hernias. We have analyzed the data on failures and complications of synthetic implants. We paid a special attention to available techniques, such as endoprostheses fixation without sutures as well as to the fixation using various types of glue. Our review is based on its own experimental and clinical data as well as the data from world's best hospitals. We found that the use of fibrin glue frequently leads to formation of seromas and hematomas, whereas albumin-glutaraldehyde glue may result in abscesses and pyogenic inflammatory infections of surgical sites. The authors pointed out the importance of further research for the optimal fixation of the prosthetic mesh in hernia repair.


2007 ◽  
Vol 17 (1) ◽  
pp. 12-15 ◽  
Author(s):  
Emanuele Santoro ◽  
Ferdinando Agresta ◽  
Francesco Buscaglia ◽  
Giacco Mulieri ◽  
Giorgio Mazzarolo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document