scholarly journals Effects of Environmental Factors on Partial Discharge Activity and Estimation of Insulation Lifetime in Electrical Machines

IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 108491-108502
Author(s):  
Waqar Hassan ◽  
Ghulam Amjad Hussain ◽  
Farhan Mahmood ◽  
Salman Amin ◽  
Matti Lehtonen
2013 ◽  
Vol 62 (4) ◽  
pp. 629-648
Author(s):  
Zbigniew Plutecki ◽  
Sławomir Szymaniec

Abstract The article presents the results of diagnostic measurements of partial discharge signal propagation from the winding insulation in electrical machinery, which were performed using an on-line method. This paper describes the results of experiments and the acquired experience in the monitoring of winding insulation in high power and high voltage electrical machines which are important in industrial production processes. The authors show the measurement techniques employed in their research. Representative measurement results are presented along with their analysis. The authors use an SKF monitoring systems to measure: vibrations, temperature, and humidity, as major factors affecting partial discharge activity in the from winding insulation of electrical machines.


2009 ◽  
Vol 129 (12) ◽  
pp. 922-930 ◽  
Author(s):  
Kai Zhou ◽  
Guangning Wu ◽  
Xiaoxia Guo ◽  
Liren Zhou ◽  
Tao Zhang

Author(s):  
Vincenzo Madonna ◽  
Paolo Giangrande ◽  
Weiduo Zhao ◽  
He Zhang ◽  
Chris Gerada ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document