scholarly journals Statistical Analysis of Partial Discharges from Electrical Trees Grown in a Flexible Epoxy Resin

Author(s):  
S. J. Dodd ◽  
N. Chalashkanov ◽  
J. C. Fothergill
2014 ◽  
Vol 4 (4) ◽  
pp. 662-668 ◽  
Author(s):  
V. A. Kioussis ◽  
M. Danikas ◽  
D. D. Christantoni ◽  
G. E. Vardakis ◽  
Α. Bairaktari

Epoxy resin and mica sheets consist the essential insulation of rotating machine stator bars. Such an insulation, although very resistant to partial discharges, is subjected to considerable electrical stresses and consequently electrical trees may ensue. In this paper, an effort is  made to simulate electrical tree propagation in multiple epoxy resin/mica sheets with the aid of Cellular Automata (CA). An attempt to compare the simulation results with experimental results is also made.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2562
Author(s):  
Abdullahi Abubakar Mas’ud ◽  
Arunachalam Sundaram ◽  
Jorge Alfredo Ardila-Rey ◽  
Roger Schurch ◽  
Firdaus Muhammad-Sukki ◽  
...  

In high-voltage (HV) insulation, electrical trees are an important degradation phenomenon strongly linked to partial discharge (PD) activity. Their initiation and development have attracted the attention of the research community and better understanding and characterization of the phenomenon are needed. They are very damaging and develop through the insulation material forming a discharge conduction path. Therefore, it is important to adequately measure and characterize tree growth before it can lead to complete failure of the system. In this paper, the Gaussian mixture model (GMM) has been applied to cluster and classify the different growth stages of electrical trees in epoxy resin insulation. First, tree growth experiments were conducted, and PD data captured from the initial to breakdown stage of the tree growth in epoxy resin insulation. Second, the GMM was applied to categorize the different electrical tree stages into clusters. The results show that PD dynamics vary with different stress voltages and tree growth stages. The electrical tree patterns with shorter breakdown times had identical clusters throughout the degradation stages. The breakdown time can be a key factor in determining the degradation levels of PD patterns emanating from trees in epoxy resin. This is important in order to determine the severity of electrical treeing degradation, and, therefore, to perform efficient asset management. The novelty of the work presented in this paper is that for the first time the GMM has been applied for electrical tree growth classification and the optimal values for the hyperparameters, i.e., the number of clusters and the appropriate covariance structure, have been determined for the different electrical tree clusters.


1994 ◽  
pp. 635-641 ◽  
Author(s):  
Helena Slowikowska ◽  
T. Łas ◽  
J. Slowikowski ◽  
R. J. Van Brunt

Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5722
Author(s):  
Shihang Wang ◽  
Chuang Zhang ◽  
Hang Fu ◽  
Jiao Xiang ◽  
Jianying Li ◽  
...  

Insulation fails quickly under high-frequency AC high voltage, especially bipolar square-wave voltage with a high dV/dt. It is of great significance to study the failure mechanism of epoxy casting insulation under such kind of voltage. In this paper, pin-plane epoxy casting insulation samples with air gaps were prepared, and the relation between the electrical trees under the high frequency bipolar square-wave voltage and the air gap conditions and voltage frequencies (1~20 kHz) were studied. Results indicated that, with the presence of air gaps, the electrical trees were bush-type and had a relatively slow growth rate, which was different from the fast-growing branch-type trees in the samples without air gap. The electrical tree characteristics related with the size of air gap and voltage frequency were also studied. The electrical tree grew faster under higher voltage frequency or with a smaller air gap. Results proved that discharge introduced a lot of defects for the surface layer of the epoxy resin samples and hence induced the possibility of multi-directional expansion of electrical trees. In addition, the resulting heat accumulation and unique charge transport synergistically affected the electrical tree characteristics under the high frequency bipolar square-wave voltage.


2013 ◽  
Vol 46 (33) ◽  
pp. 335301 ◽  
Author(s):  
H A Illias ◽  
G Chen ◽  
A H A Bakar ◽  
H Mokhlis ◽  
M A Tunio

Author(s):  
J.M. Martinez-Tarifa ◽  
J.A. Ardila-Rey ◽  
A. Prieto-Duque ◽  
J.M. Fresno ◽  
G. Robles

Sign in / Sign up

Export Citation Format

Share Document