Electric power quality issues: Harmonic analysis for real network

Author(s):  
Constantin Barbulescu ◽  
Marius Cornoiu ◽  
Stefan Kilyeni ◽  
Constantin Stoian ◽  
Petre Stoian
2019 ◽  
Vol 114 ◽  
pp. 04002
Author(s):  
Vyacheslav Zyryanov ◽  
Roman Khatylenko ◽  
Anton Potapenko

The monitoring results of 6 kV diesel power plant mode parameters are presented in the paper. The diesel power plant supplies the drilling unit of the oil production enterprise. The main goal of the paper is to estimate electric power quality indexes connected with voltage unsinusoidality of the monitored off-grid power system, to compare them with specified in State Standard 32144-2013 [1] and to provide high harmonics reduce methods. The real mode parameters measurements of 3600 kVA diesel power plant in different technological processes connected with oil production were used during the research. The MATLAB software and integrated Fourier transform function were applied to elaborate the mode parameters measurements. Based on harmonic analysis generalized results it is obtained that in many technological processes electric power quality indexes fail to meet the requirements of State Standard 32144-2013 [1]. The filter compensating device with reactive power 1350 kvar installed on 6 kV bus doesn’t allow to supply required electric power quality indexes. The DC drive thyristors rectifiers and the frequency converters of the asynchronous motors of the drill unit parts are the main sources of high harmonics in steady-state modes. The harmonic composition essential changes and electric power quality indexes are reduced due to load power dumps and surges. The high harmonics in such modes are caused by transients in synchronous generators providing supply of the considered power system. The quick-operating electric energy storage system with active power filter function [2] has been proposed as a method to reduce the harmonics.


2003 ◽  
Vol 1 (01) ◽  
pp. 193-197 ◽  
Author(s):  
F. Magnago ◽  
◽  
C. Reineri ◽  
S. Lovera ◽  
R. Lima ◽  
...  

2015 ◽  
Vol 135 (5) ◽  
pp. 272-275
Author(s):  
Shoji Nishimura ◽  
Shigeru Inno ◽  
Tatsuki Okamoto

2020 ◽  
Vol 11 (7-2020) ◽  
pp. 58-66
Author(s):  
Vera V. Yaroshevich ◽  
◽  
Aleksei S. Karpov ◽  
Galina P. Fastiy ◽  
Sergei V. Smotrov ◽  
...  

The systematization and analysis of the results of monitoring registrations of electric power quality indicators (PQS) on substation buses feeding large industrial enterprises of the Murmansk region was carried out. The example of existing substations shows the problems of high-energy facilities that have consumers with non-linear parameters. The problems of electromagnetic compatibility of industrial consumers with the mains have been identified. The need for research to identify the causes of non-compliance is proved. A number of the most common and effective measures to limit the distortion of the SCE are proposed.


Sign in / Sign up

Export Citation Format

Share Document