Study on binocular stereo camera calibration method

Author(s):  
Guo Yan Xu ◽  
Li Peng Chen ◽  
Feng Gao
2011 ◽  
Vol 460-461 ◽  
pp. 219-224 ◽  
Author(s):  
Jun Tao Xiong ◽  
Xiang Jun Zou ◽  
Hai Xin Zou ◽  
Yin Le Chen ◽  
Quan Sun

Aiming at the camera calibration of binocular stereo vision system, based on Zhang’s calibration method, the specified points in the calibration template obtained by the Harris operator, a set of camera calibration system combined with VC++ and Matlab was developed. The results of the calibration system, comparing with those of four-step calibration method, was analyzed and showed that: the error of calibration data in this system was within 0~5 mm, which had a high precision calibration, providing a new reference measure for the camera calibration.


2013 ◽  
Vol 475-476 ◽  
pp. 184-187
Author(s):  
Wen Guo Li ◽  
Shao Jun Duan

We present a camera calibration method based on circle plane board. The centres of circles on plane are regarded as the characteristic points, which are used to implement camera calibration. The proposed calibration is more accurate than many previous calibration algorithm because of the merit of the coordinate of circle centre being obtained from thousand of of edge pionts of ellipse, which is very reliable to image noise caused by edge extraction algorithm. Experiments shows the proposed algorithm can obtain high precise inner parameters, and lens distortion parameters.


2014 ◽  
Vol 568-570 ◽  
pp. 320-325 ◽  
Author(s):  
Feng Shan Huang ◽  
Li Chen

A new CCD camera calibration method based on the translation of Coordinate Measuring Machine (CMM) is proposed. The CMM brings the CCD camera to produce the relative translation with respect to the center of the white ceramic standard sphere along the X, Y, Z axis, and the coordinates of the different positions of the calibration characteristic point in the probe coordinate system can be generated. Meanwhile, the camera captures the image of the white ceramic standard sphere at every position, and the coordinates of the calibration characteristic point in the computer frame coordinate system can be registered. The calibration mathematic model was established, and the calibration steps were given and the calibration system was set up. The comparing calibration result shows that precision of this method is equivalent to that of the special calibration method, and the difference between the calibrating data of these two methods is within ±1μm.


Sign in / Sign up

Export Citation Format

Share Document