Automatic sequential reactive power compensation and harmonic suppression at loads using appliance clustering and power quality monitoring

Author(s):  
K. Shashikumar ◽  
C. Venkataseshaiah ◽  
K. S. Sim
2020 ◽  
pp. 1-11
Author(s):  
Zhimei Duan ◽  
Xiaojin Yuan ◽  
Rongfei Zhu

Harmonic pollution and reactive power consumption are the two most important factors affecting power quality. Power electronics, as the largest harmonic source, will produce a large number of harmonics while running, and will also lose reactive power, reduce the power factor of the system and affect power quality. Firstly, the current situation of reactive power and harmonic suppression based on fuzzy control is briefly introduced. Then, the harmonic component and power factor of the power grid are taken as two objective functions to model the power grid. The improved particle swarm optimization (PSO) genetic algorithm is used to establish the harmonic suppression and reactive power compensation model. To improve the design efficiency, aiming at the complexity of the algorithm and the field measurement data, the reactive power compensation device is quickly solved on the Hadoop cloud computing platform to achieve the global optimal compensation effect, to improve the convergence speed and global search ability of the particle swarm optimization algorithm. Thus, based on ensuring the power factor, the harmonic component is restrained and the safety and reliability of power grid operation are improved.


2015 ◽  
Vol 9 (1) ◽  
pp. 591-599
Author(s):  
Ma Wenchuan ◽  
Zhitong Li ◽  
Chen Daochang ◽  
Qi Jiaming ◽  
Zhou Qiang ◽  
...  

For resolving the problem that power filter cannot work normally because TCR (thyristor controlled reactor) generates extra third harmonic current under asymmetrical voltage, the paper proposes the estimation method of current capacity that TCR generates extra third harmonic current under asymmetrical voltage. Considering extra third harmonic current under asymmetrical voltage, Optimum method based on genetic algorithm is used to design the parameters of power filter. With reactive power compensation and harmonic suppression project of a steel mill as example, the proposed method is simulated by Matlab. Simulation results show optimized power filter can eliminate extra third harmonic current effects under asymmetrical voltage, meet the requirement of reactive power compensation, reduce harmonics current that load injects into system, and guarantee the power filter safe operation under asymmetrical voltage.


Author(s):  
Carlos. A. Duque ◽  
Leandro Manso Rodrigues Silva ◽  
Guilherme Marcio Soares ◽  
Ildemar C. Deckman ◽  
Jose Luiz R. Pereira ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document