Short circuit current calculation of non full measured distribution network based on modified power flow algorithm

Author(s):  
Jun Li ◽  
Hong Xiao ◽  
Zhichao Huang ◽  
Shuangjiang Shen ◽  
Tong Zhang
2014 ◽  
Vol 1070-1072 ◽  
pp. 897-901
Author(s):  
Guang Ming Lu ◽  
Wei Zhang ◽  
Jian Feng Yan ◽  
Yong Jun Yu ◽  
Zhi Hong Yu ◽  
...  

In daily operation process,the results of online short-circuit current calculation and fault wave recording is different, the differences between the two results affected the dispatcher’s decision. In-depth analysis of the calculation process and finding the possible causes of the differences should be done. The on-line PSASP short-circuit current calculation based on power flow and scheme was studied. The boundary conditions and calculation models of two methods were studied, the influence of the modeling scope and equivalent circuits to the short-circuit current was also studied. Fault wave recording calculated short-circuit current through forward calculation, the middle to both sides calculation and backward calculation, and the differences of the three calculation mode were also analyzed. Through the above analysis and comparison, online data equivalent to 220kV high voltage side of the transformer greatly impacts short-circuit current, but effective value calculation method of fault wave recording has a little impact on the short-circuit current, mainly in the following reasons, the first one is that non-dispatching power plant is equivalent to a load, the second one is that several different types of load is equivalent to a load using one load model, the third one is that all devices connecting to low voltage side of the 220kV transformers are equivalent to 220kV. Conclusions of the analysis can provide the basis for the practical work of online short-circuit current calculation.


2022 ◽  
Vol 8 ◽  
pp. 1481-1485
Author(s):  
Qi Wang ◽  
Xiaojie Pan ◽  
Bing Zhao ◽  
Pandeng Luo ◽  
Jie Hao ◽  
...  

2013 ◽  
Vol 805-806 ◽  
pp. 1082-1086
Author(s):  
Jun Li ◽  
Zhi Fei Chen ◽  
Jun Xia Qian ◽  
Hui Gang Zhang

Considering that microgrid (MG) can be controlled flexibly, its short circuit-current is limited and power flow is bidirectional. The paper presents a new relay protection scheme of microgrid based specific harmonic injection method. The injective harmonic flows all over microgrid and the amplitude of specific harmonic current will enhance in fault occasion. So the above characteristic can solve the problem of fault position and the symmetric characteristic can complete the identification of fault type. The discussion about the compatibility of microgrid protection and conventional distribution network line protection. At last, the combined microgrid model is built in Matlab/Simulink environment. The simulation result demonstrated that the above method can complete the identification of fault position and type and it also can coordinate with the traditional line protection well.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Shan Yang ◽  
Xiangqian Tong

Power flow calculation and short circuit calculation are the basis of theoretical research for distribution network with inverter based distributed generation. The similarity of equivalent model for inverter based distributed generation during normal and fault conditions of distribution network and the differences between power flow and short circuit calculation are analyzed in this paper. Then an integrated power flow and short circuit calculation method for distribution network with inverter based distributed generation is proposed. The proposed method let the inverter based distributed generation be equivalent toIθbus, which makes it suitable to calculate the power flow of distribution network with a current limited inverter based distributed generation. And the low voltage ride through capability of inverter based distributed generation can be considered as well in this paper. Finally, some tests of power flow and short circuit current calculation are performed on a 33-bus distribution network. The calculated results from the proposed method in this paper are contrasted with those by the traditional method and the simulation method, whose results have verified the effectiveness of the integrated method suggested in this paper.


2013 ◽  
Vol 325-326 ◽  
pp. 624-627 ◽  
Author(s):  
Ming Jun Chen ◽  
Chen Zhu Xuan ◽  
Xin Kai Lian

when the photovoltaic power generation and thermoelectric power factory connect into the distribution network , the system change from one source to several sources. it will change the construction of the system and the system power flow ,and also the size and direction of short-circuit current. It is harder to prepare the grid protection devices and set value for the protection. This paper studied the complex electronic systems which contains wind farms and thermoelectric power factory, analysis the change of voltage and current of each bus when the fault happen after the photovoltaic power generation connected into the system, and also talk about how the fault location affect the system fault component .Then conduct the expression of the fault current of each line to provide the basis for the study of multiterminal supply network protection strategy.


2014 ◽  
Vol 1070-1072 ◽  
pp. 938-942 ◽  
Author(s):  
Shu Zheng ◽  
Zhi Hua Xu ◽  
Jia Jia Liu ◽  
Qiang Fu

A new relay protection based on electronic communication is presented for the access of distributed generation. After distributed generation access to the system, distribution network power flow direction and short-circuit current level will change. This paper describes the effects of distributed generation on distributed network by building feeder system simplified PSCAD/ EMTDC model. According to the analysis, the new relay protection can improve the stability and reliability of distributed network.


2013 ◽  
Vol 756-759 ◽  
pp. 2779-2784
Author(s):  
Nan Hua Yu ◽  
Xiao Ping Zhang ◽  
Xin Yu Wang ◽  
Run Ze Wu ◽  
Wen Xia Liu

DER access to the distribution network will change the characteristics of power flow, the network short-circuit current levels and introduce a large number of harmonic interference in the traditional distribution network, which requires effective communication scheme as a monitor. In this paper, we analyze the requirements of the distribution of business and DER grid monitoring business, combined with the characteristics of a various types of communication, give a communication scheme of distribution network containing DERs. The program can be used as a reference for future distribution communication network construction with certain practical value.