Comparison of current controllers based on repetitive-based control and second order generalized integrators for active power filters

Author(s):  
Ana Rodriguez ◽  
Carlos Giron ◽  
Mario Rizo ◽  
Vanessa Saez ◽  
Emilio Bueno ◽  
...  
2019 ◽  
Vol 11 (11) ◽  
pp. 168781401989079
Author(s):  
Yun Chen ◽  
Siyang Li ◽  
Juntao Fei

Because of the heavy use of electrical equipment, harmonic pollution is becoming more and more serious, which brings potential safety risks to our lives. In view of the fact that active power filters can effectively eliminate harmonics, an adaptive second-order sliding mode fuzzy control based on the backstepping method is proposed to eliminate harmonics in this article. The second-order sliding mode control can eliminate chattering in the system and results in a smoother controller. The uncertainties in the system are approximated by a fuzzy control system, and the adaptive laws are designed to ensure the stability of the system. Backstepping control can improve the stability and robustness of closed-loop systems. Simulation results show that the proposed method has better tracking effect, strong robustness, and stability and can effectively eliminate harmonics.


2018 ◽  
Vol 1 (1) ◽  
pp. 54-66
Author(s):  
Rakan Khalil Antar ◽  
Basil Mohammed Saied ◽  
Rafid Ahmed Khalil

A new control strategy for active power filters is proposed, modeled and implemented in order to improve the power quality of a line commutated converter High voltage DC link. The ability of reactive power and harmonics reductions are generally met by using passive and active power filters. In this paper, modified active power filter with a modified harmonics pulse width modulation algorithm is used to minimize the source harmonics and force the AC supply current to be in the same phase with AC voltage source at both sending and receiving sides of a line commutated converter high voltage DC link. Therefore, it is considered as power factor corrector and harmonics eliminator with random variations in the load current. The modified harmonics pulse width modulation algorithm is applicable for active power filter based on a three-phase five-level and seven-level cascaded H-bridge voltage source inverter. Simulation results show that the suggested modified multilevel active power filters improve total harmonics distortion of both voltage and current with almost unity effective power factor at both AC sides of high voltage DC link. Therefore, modified active power filter is an effective tool for power quality improvement and preferable for line commutated converter high voltage DC link at different load conditions.


Author(s):  
Ana-Maria Dumitrescu ◽  
Valeriu Bostan ◽  
Sanda Victorinne Paturca ◽  
Ionel Bostan ◽  
Razvan Matei Magureanu

2015 ◽  
Vol 267 ◽  
pp. 648-654 ◽  
Author(s):  
Marcin Maciążek ◽  
Dariusz Grabowski ◽  
Marian Pasko ◽  
Michał Lewandowski

2013 ◽  
Vol 811 ◽  
pp. 657-660 ◽  
Author(s):  
You Jie Ma ◽  
Hong De Yuan ◽  
Xue Song Zhou

With the wide application of power electronic equipments in power system, more and more harmonic are poured into the power system, which cause power pollution and make the power quality problem increasingly serious. Active power filter (APF) is an important equipment to compensate harmonic and reactive current in power system. One of the key technologies lies in the real-time and accurate control. The fundamental principles of several control strategies of compensate current were presented, and the respective merit and demerit of these control strategies were pointed out with contrast analysis in this paper. Active power filter will achieve a higher performance and a wider application with the continuous development of the control strategy.


Sign in / Sign up

Export Citation Format

Share Document