scholarly journals Dual Band Kinetic Inductance Bolometers for Submillimeter-wave Imaging: Experimental and Theoretical Optical Response

Author(s):  
S.O. Dabironezare ◽  
J. Hassel ◽  
E. Gandini ◽  
L. Gronberg ◽  
H. Sipola ◽  
...  
Author(s):  
Juha Hassel ◽  
Shahab Oddin Dabironezare ◽  
Erio Gandini ◽  
Leif Grönberg ◽  
Hannu Sipola ◽  
...  

2018 ◽  
Vol 8 (6) ◽  
pp. 746-756 ◽  
Author(s):  
Shahab Oddin Dabironezare ◽  
Juha Hassel ◽  
Erio Gandini ◽  
Leif Gronberg ◽  
Hannu Sipola ◽  
...  

2018 ◽  
Vol 609 ◽  
pp. A115 ◽  
Author(s):  
R. Adam ◽  
A. Adane ◽  
P. A. R. Ade ◽  
P. André ◽  
A. Andrianasolo ◽  
...  

Context. Millimetre-wave continuum astronomy is today an indispensable tool for both general astrophysics studies (e.g. star formation, nearby galaxies) and cosmology (e.g. cosmic microwave background and high-redshift galaxies). General purpose, large-field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the high-resolution interferometers (e.g. ALMA in Chile, NOEMA in the French Alps) and by the coarse angular resolution space-borne or ground-based surveys (e.g. Planck, ACT, SPT). These instruments have to be installed at the focal plane of the largest single-dish telescopes, which are placed at high altitude on selected dry observing sites. In this context, we have constructed and deployed a three-thousand-pixel dual-band (150 GHz and 260 GHz, respectively 2 mm and 1.15 mm wavelengths) camera to image an instantaneous circular field-of-view of 6.5 arcmin in diameter, and configurable to map the linear polarisation at 260 GHz. Aims. First, we are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focussing on the cryogenics, optics, focal plane arrays based on Kinetic Inductance Detectors, and the readout electronics. The focal planes and part of the optics are cooled down to the nominal 150 mK operating temperature by means of an adhoc dilution refrigerator. Secondly, we are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-m IRAM telescope at Pico Veleta, near Granada (Spain). Methods. We have targeted a number of astronomical sources. Starting from beam-maps on primary and secondary calibrators we have then gone to extended sources and faint objects. Both internal (electronic) and on-the-sky calibrations are applied. The general methods are described in the present paper. Results. NIKA2 has been successfully deployed and commissioned, performing in-line with expectations. In particular, NIKA2 exhibits full width at half maximum angular resolutions of around 11 and 17.5 arcsec at respectively 260 and 150 GHz. The noise equivalent flux densities are, at these two respective frequencies, 33±2 and 8±1 mJy s1/2. A first successful science verification run was achieved in April 2017. The instrument is currently offered to the astronomy community and will remain available for at least the following ten years.


2014 ◽  
Author(s):  
G. Coiffard ◽  
K. F. Schuster ◽  
A. Monfardini ◽  
A. Adane ◽  
B. Barbier ◽  
...  

2013 ◽  
Author(s):  
Ken B. Cooper ◽  
Theodore A. Reck ◽  
Cecile Jung-Kubiak ◽  
Choonsup Lee ◽  
Jose V. Siles ◽  
...  

2020 ◽  
Vol 637 ◽  
pp. A71 ◽  
Author(s):  
L. Perotto ◽  
N. Ponthieu ◽  
J. F. Macías-Pérez ◽  
R. Adam ◽  
P. Ade ◽  
...  

Context. NIKA2 is a dual-band millimetre continuum camera of 2 900 kinetic inductance detectors, operating at 150 and 260 GHz, installed at the IRAM 30-m telescope in Spain. Open to the scientific community since October 2017, NIKA2 will provide key observations for the next decade to address a wide range of open questions in astrophysics and cosmology. Aims. Our aim is to present the calibration method and the performance assessment of NIKA2 after one year of observation. Methods. We used a large data set acquired between January 2017 and February 2018 including observations of primary and secondary calibrators and faint sources that span the whole range of observing elevations and atmospheric conditions encountered by the IRAM 30-m telescope. This allowed us to test the stability of the performance parameters against time evolution and observing conditions. We describe a standard calibration method, referred to as the “Baseline” method, to translate raw data into flux density measurements. This includes the determination of the detector positions in the sky, the selection of the detectors, the measurement of the beam pattern, the estimation of the atmospheric opacity, the calibration of absolute flux density scale, the flat fielding, and the photometry. We assessed the robustness of the performance results using the Baseline method against systematic effects by comparing results using alternative methods. Results. We report an instantaneous field of view of 6.5′ in diameter, filled with an average fraction of 84%, and 90% of valid detectors at 150 and 260 GHz, respectively. The beam pattern is characterised by a FWHM of 17.6″ ± 0.1″ and 11.1″ ± 0.2″, and a main-beam efficiency of 47%±3%, and 64%±3% at 150 and 260 GHz, respectively. The point-source rms calibration uncertainties are about 3% at 150 GHz and 6% at 260 GHz. This demonstrates the accuracy of the methods that we deployed to correct for atmospheric attenuation. The absolute calibration uncertainties are of 5%, and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below 1% in both channels. The noise equivalent flux density at 150 and 260 GHz are of 9 ± 1 mJy s1/2 and 30 ± 3 mJy s1/2. This state-of-the-art performance confers NIKA2 with mapping speeds of 1388 ± 174 and 111 ± 11 arcmin2 mJy−2 h−1 at 150 and 260 GHz. Conclusions. With these unique capabilities of fast dual-band mapping at high (better that 18″) angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.


Sign in / Sign up

Export Citation Format

Share Document