Common mode impedance model of power electronic equipment to evaluate noise reduction effect of a line noise filter

Author(s):  
M. Kanda ◽  
N. Oka ◽  
S. Nitta
2010 ◽  
Vol E93-B (7) ◽  
pp. 1788-1796 ◽  
Author(s):  
Takanori UNO ◽  
Kouji ICHIKAWA ◽  
Yuichi MABUCHI ◽  
Atsushi NAKAMURA ◽  
Yuji OKAZAKI ◽  
...  

2019 ◽  
Vol 139 (12) ◽  
pp. 657-662
Author(s):  
Minghui Chen ◽  
Jianqing Wang ◽  
Daisuke Anzai ◽  
Georg Fischer

2010 ◽  
Vol 130 (5) ◽  
pp. 479-480
Author(s):  
Takanori Uno ◽  
Kouji Ichikawa ◽  
Yuichi Mabuchi ◽  
Atushi Nakamura

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2568
Author(s):  
Tadeas Bednar ◽  
Branko Babusiak ◽  
Michal Labuda ◽  
Milan Smetana ◽  
Stefan Borik

A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm2, 3300 cm2, and 4950 cm2, respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm2, the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system’s financial costs due to the smaller electrode area made of the costly conductive textile.


2021 ◽  
Vol 11 (9) ◽  
pp. 3869
Author(s):  
Chen Niu ◽  
Yongwei Liu ◽  
Dejiang Shang ◽  
Chao Zhang

Superhydrophobic surface is a promising technology, but the effect of superhydrophobic surface on flow noise is still unclear. Therefore, we used alternating free-slip and no-slip boundary conditions to study the flow noise of superhydrophobic channel flows with streamwise strips. The numerical calculations of the flow and the sound field have been carried out by the methods of large eddy simulation (LES) and Lighthill analogy, respectively. Under a constant pressure gradient (CPG) condition, the average Reynolds number and the friction Reynolds number are approximately set to 4200 and 180, respectively. The influence on noise of different gas fractions (GF) and strip number in a spanwise period on channel flow have been studied. Our results show that the superhydrophobic surface has noise reduction effect in some cases. Under CPG conditions, the increase in GF increases the bulk velocity and weakens the noise reduction effect. Otherwise, the increase in strip number enhances the lateral energy exchange of the superhydrophobic surface, and results in more transverse vortices and attenuates the noise reduction effect. In our results, the best noise reduction effect is obtained as 10.7 dB under the scenario of the strip number is 4 and GF is 0.5. The best drag reduction effect is 32%, and the result is obtained under the scenario of GF is 0.8 and strip number is 1. In summary, the choice of GF and the number of strips is comprehensively considered to guarantee the performance of drag reduction and noise reduction in this work.


Sign in / Sign up

Export Citation Format

Share Document