Decoupled sliding mode control for three-phase LCL VSI operating at fixed switching frequency

Author(s):  
Eduardo Alarcon-Gallo ◽  
Luis Garcia de Vicuna ◽  
Miguel Castilla ◽  
Jaume Miret ◽  
Jose Matas ◽  
...  
2016 ◽  
Vol 31 (1) ◽  
pp. 758-769 ◽  
Author(s):  
Ramon Guzman ◽  
Luis Garcia de Vicuna ◽  
Javier Morales ◽  
Miguel Castilla ◽  
Jose Matas

2019 ◽  
Vol 8 (3) ◽  
pp. 8015-8019

In this paper, a Three-Level Hysteresis based Sliding (TLHSM) function approach to regulate output currents of three-phase capacitor powered Voltage Source Inverter (VSI) is analyzed and implemented. VSI functions as shunt active power filter to compensate for harmonic currents generated by a nonlinear load in the power distribution network. The performance of the control is compared with conventional two-level hysteresis-based control through simulation in MATLAB/Simulink. Sliding Mode Control (SMC) is recognized as robust controller with a high stability over a wide range of load and source variations. The set-back of unfixed switching frequency problem with conventional two-level hysteresis control is disregarded in this approach. Switching frequency prediction is observed to be accurate. The tracking error and Total Harmonic Distortion (THD) in source currents are the measurable parameters for evaluation of control effort and is within the limits specified by IEEE519:2014 recommendations.


2017 ◽  
Vol 32 (2) ◽  
pp. 1557-1569 ◽  
Author(s):  
Victor Repecho ◽  
Domingo Biel ◽  
Josep M. Olm ◽  
Enric Fossas Colet

2017 ◽  
Vol 14 (5) ◽  
pp. 459-466 ◽  
Author(s):  
Fiaz Ahmad ◽  
Akhtar Rasool ◽  
Esref Emre Ozsoy ◽  
Asif Sabanoviç ◽  
Meltem Elitas

Purpose This paper aims to propose a robust cascaded controller based on proportional-integral (PI) and continuous sliding mode control. Design/methodology/approach Cascaded control structure is an attractive control scheme for DC-DC power converters. It has a two-loop structure where the outer loop contains PI controller and the inner loop uses sliding mode control (SMC). This structure thus combines the merits of both the control schemes. However, there are some issues that have prohibited its adoption in industry, the discontinuous nature of SMC which leads to variable switching frequency operation and is hard to realize practically. This paper attempts to overcome this issue by changing the discontinuous functionality of SMC to continuous by utilizing the concept of equivalent control. Findings The robustness of the controller designed is verified by considering various cases, namely, ideal case with no uncertainties, sudden variation of input supply voltage, load resistance, reference voltage, circuit-parameters and for noise disturbance. The controller effectiveness is validated by simulating the DC-DC boost and Cuk converters in SimPowerSystems toolbox of MATLAB/Simulink. It is shown that the performance of the proposed controller is satisfactory, and both reference output voltage and inductor current are tracked with little or no sensitivity to disturbances. Originality/value The results for various scenarios are interesting and show that the controller works quite satisfactorily for all the simulated uncertainties.


Sign in / Sign up

Export Citation Format

Share Document