Large Power Transformer Magnetic Core Vibration Model by Using Dynamic Genetic Algorithm

Author(s):  
Janis Marks
2019 ◽  
Vol 56 (3) ◽  
pp. 13-25
Author(s):  
J. Marks ◽  
S. Vitolina ◽  
J. Dirba

Abstract Magnetostriction process creates vibrations within magnetic core of a power transformer. This effect can cause delamination of magnetic core layers and increase the vibration amplitudes on the surface of transformer tank. In this paper, a magnetostrictive vibration model is proposed for improved evaluation of the mechanical integrity of magnetic core and the finding of possible mechanical defects. This model is based on the simulation of magnetostrictive vibrations by replacing the magnetic core with mass and spring system, and application of a dynamic genetic algorithm in order to find the necessary system configuration. A case study is provided structurally modelling magnetic core in Matlab and Matlab Simulink with the analysis of simulated vibrations that indicate a possible mechanical defect.


2020 ◽  
Vol 67 (1) ◽  
pp. 42-47
Author(s):  
Anatoliy I. Sopov ◽  
Aleksandr V. Vinogradov

In power transformers, energy losses in the form of heat are about 2 percent of their rated power, and in transformers of large power centers reach hundreds of kilowatts. Heat is dissipated into the environment and heats the street air. Therefore, there is a need to consume this thermal energy as a source of heat supply to nearby facilities. (Research purpose) To develop methods and means of using excess heat of power transformers with improvement of their cooling system design. (Materials and methods) The authors applied following methods: analysis, synthesis, comparison, monographic, mathematical and others. They analyzed various methods for consuming excess heat from power transformers. They identified suitable heat supply sources among power transformers and potential heat consumers. The authors studied the reasons for the formation of excess heat in power transformers and found ways to conserve this heat to increase the efficiency of its selection. (Results and discussion) The authors developed an improved power transformer cooling system design to combine the functions of voltage transformation and electric heating. They conducted experiments to verify the effectiveness of decisions made. A feasibility study was carried out on the implementation of the developed system using the example of the TMG-1000/10/0.4 power transformer. (Conclusions) The authors got a new way to use the excess heat of power transformers to heat the AIC facilities. It was determined that the improved design of the power transformer and its cooling system using the developed solutions made it possible to maximize the amount of heat taken off without quality loss of voltage transformation.


2012 ◽  
Vol 433-440 ◽  
pp. 7287-7292
Author(s):  
You Hua Gao ◽  
Zeng Feng Lai ◽  
Xiao Ming Liu ◽  
Guo Wei Liu ◽  
Ye Wang

To analyze the transient response of transformer windings under very fast transient over-voltage (VFTO), multi-conductor transmission line (MTL) model based on the representation of transformer windings by its individual turns are established. Space discretization is needed for solving the time-domain telegraph equations of MTL. To calculate the voltage distributions along transformer windings, through combining the compact finite difference (CFD) theory and the backward differentiation formulas (BDF). Simulation software ATP is introduced, and the simulation results demonstrate that the proposed approach is feasible.


Author(s):  
Mahfoud Chafai ◽  
Larbi Refoufi ◽  
Hamid Bentarzi