Control of Multifunctional PV-Battery Storage System with Power Quality Enhancement of Utility Grid

Author(s):  
Shubhra ◽  
Bhim Singh
2013 ◽  
Vol 694-697 ◽  
pp. 838-841 ◽  
Author(s):  
Li Xia Lv ◽  
Yue Xia Jin

In order to solve the problems which are caused by wind power and solar power on-grid, such as power quality, stability, reliability and so on, this paper proposes wind and solar micro-grid including energy storage system(ESS). The micro-grid uses two buses: AC bus and DC bus. Micro-source current is connected to the grid with the same inverter, which can reduce the micro-grid control difficulties. The energy storage system connected to the grid through the inverter could directly absorb energy from the grid. The DC side of the energy storage system using bidirectional DC / DC converter, which can keep the DC side of the battery storage stable.


Author(s):  
Salman Hajiaghasi ◽  
Ahmad Salemnia ◽  
Mohsen Hamzeh

Increasing nonlinear loads and power electronic converters lead to various power quality issues in microgrids (MGs). The interlinking converters (ILCs) can participate in these systems to harmonic control and power quality enhancement. However, ILC participation deteriorates the dc link voltage, system stability, and storage lifetime due to oscillatory current phenomena. To address these problems, a new control strategy for a hybrid energy storage system (HESS) is proposed to eliminate the adverse effects of the harmonic control operation of ILC. Specifically, battery and super-capacitor (SC) are used as HESSs that provide low and high power frequency load, respectively. The proposed strategy tries to compensate the current oscillation imposed by ILC with fuzzy control of HESS. In this method, a proportional-resonant (PR) controller integrated with harmonic compensator (HC) is employed to control the ILC for power quality enhancement and oscillatory current elimination. The main advantages of the proposed strategy are to reduce DGs power fluctuations, precise DC bus voltage regulation for generation and load disturbances, improved grid power quality under nonlinear load and transition conditions. The performance of the proposed method for isolated and grid-connected modes is verified using simulation studies in the MATLAB software environment.


IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 107614-107634 ◽  
Author(s):  
Gajendra Singh Chawda ◽  
Abdul Gafoor Shaik ◽  
Om Prakash Mahela ◽  
Sanjeevikumar Padmanaban ◽  
Jens Bo Holm-Nielsen

2014 ◽  
pp. 349-354 ◽  
Author(s):  
A. Yanushkevich ◽  
Z. Müller ◽  
J. Švec ◽  
J. Tlustý ◽  
V. Valouch

2018 ◽  
Vol 1 ◽  
pp. 345-349
Author(s):  
G. Fernández ◽  
◽  
H. Bludszuweit ◽  
J. Torres ◽  
J. Almajano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document