STATIC VOLTAGE STABILITY ANALYSIS ON WESTERN KENYA POWER NETWORK WITH WIND POWER PENETRATION

Author(s):  
Noah Serem ◽  
Josiah Munda ◽  
Lawrence Letting
2016 ◽  
Vol 19 (3) ◽  
pp. 5-12
Author(s):  
Binh Thi Thanh Phan ◽  
Thao Thi Thu Huynh ◽  
Au Ngoc Nguyen

The static voltage stability analysis is carried out by V-Q sensitivity or Q-V modal analysis. These analyses are based on the Jacobian matrix of power flow calculation. This is regarded as load bus stability analysis. With DFIG of PQ mode, the wind generation bus is considered as the PQ bus. Due to the limits of converters, these PQ buses became very special and this influences on the voltage stability examining. This paper also examines the penetration level and the location of wind generation injection based on voltage stability. The reliability of the algorithm is illustrated in a study of 14 buses power network.


2021 ◽  
Vol 2021 ◽  
pp. 1-16
Author(s):  
Ombuki Mogaka ◽  
Roy Orenge ◽  
Julius Ndirangu

In recent years, the Kenyan Power Network has witnessed large growths in load demand. Although the increased load demand has somewhat been matched with an increase in transmission and generation capacity, the rate of expansion has not been matched with the rate of increase in load demand due to economic, environmental, and geographical constraints. This has led to the system being prone to instability since it is being operated under stressed conditions. In the recent past, several studies have been carried out on voltage stability analysis and improvement using various conventional methods. However, conventional methods have various limitations in their utilization for voltage stability analysis. One solution to overcome these limitations is to employ a combination of one or more methods so as to get more information and greater degree of accuracy in voltage stability studies. In this paper, a methodology is proposed involving the combination of QV modal analysis, sensitivity analysis (VQ) and power-voltage curves in assessing the static voltage stability analysis taking a case study of the Kenyan Power Network. V-Q sensitivity analysis and QV modal analysis have been used to identify the load regions most susceptible to voltage instability and the corresponding weak buses in the network for various V-Q responses. Reactive power loss sensitivities for branches in the network have been used to determine the critical (weak) lines in the network. Loading margins (LM) and voltage stability margins (VSM) have then been used to determine the proximity to voltage collapse of the voltage weak buses identified by QV modal analysis. The effect of tripping one the critical lines on the voltage weak buses is also investigated. The current high voltage power network under the average peak loading conditions during the year 2019 is considered for the study. The paper also reviews existing voltage stability analysis methods and their limitations.


Author(s):  
Denis Juma ◽  
Bessie Monchusi ◽  
Josiah Munda ◽  
Adisa Jimoh

This paper investigates the impacts of a wind farm connected at Harterbeespoort substation in South Africa on voltage stability of the power network. The site wind speed was determined and analyzed for viability. A comparison is made between the use of Doubly-Fed Induction Generators and Self-excited Induction Generators driven by the wind turbines. The resulting P-V and Q-V curves from load flow studies are presented and analyzed. The models for this study were implemented in DigSILENT PowerFactory.


Sign in / Sign up

Export Citation Format

Share Document