An ABC-Based Subway Timetable Optimization Model for Regenerative Energy Utilization

Author(s):  
Hongjie Liu ◽  
Mengchu Zhou ◽  
Xiwang Guo ◽  
Haoyue Liu ◽  
Tao Tang
2019 ◽  
Vol 20 (9) ◽  
pp. 3247-3257 ◽  
Author(s):  
Hongjie Liu ◽  
MengChu Zhou ◽  
Xiwang Guo ◽  
Zizhen Zhang ◽  
Bin Ning ◽  
...  

Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1876 ◽  
Author(s):  
Hongjie Liu ◽  
Tao Tang ◽  
Jidong Lv ◽  
Ming Chai

Maximizing regenerative energy utilization is an important way to reduce substation energy consumption in subway systems. Timetable optimization and energy storage systems are two main ways to improve improve regenerative energy utilization, but they were studied separately in the past. To further improve energy conservation while maintaining a low cost, this paper presents a strategy to improve regenerative energy utilization by an integration of them, which determines the capacity of each Wayside Energy Storage System (WESS) and correspondingly optimizes the timetable at the same time. We first propose a dual-objective optimization problem to simultaneously minimize substation energy consumption and the total cost of WESS. Then, a mathematical model is formulated with the decision variables as the configuration of WESS and timetable. Afterwards, we design an ϵ -constraint method to transform the dual-objective optimization problem into several single-objective optimization problems, and accordingly design an improved artificial bee colony algorithm to solve them sequentially. Finally, numerical examples based on the actual data from a subway system in China are conducted to show the effectiveness of the proposed method. Experimental results indicate that substation energy consumption is effectively reduced by using WESS together with a correspondingly optimized timetable. Note that substation energy consumption becomes lower when the total size of WESS is larger, and timetable optimization further reduces it. A set of Pareto optimal solutions is obtained for the experimental subway line—based on which, decision makers can make a sensible trade-off between energy conservation and WESS investment accordingly to their preferences.


2018 ◽  
Vol 10 (9) ◽  
pp. 168781401879703 ◽  
Author(s):  
Hongjie Liu ◽  
Tao Tang ◽  
Xiwang Guo ◽  
Xisheng Xia

Maximizing regenerative energy utilization in subway systems has become a hot research topic in recent years. By coordinating traction and braking trains in a substation, regenerative energy is optimally utilized and thus energy consumption from the substation can be reduced. This article proposes a timetable optimization problem to maximize regenerative energy utilization in a subway system with headway and dwell time control. We formulate its mathematical model, and some required constraints are considered in the model. To keep the operation time duration constant, the headway time between different trains can be different. An improved artificial bee colony algorithm is designed to solve the problem. Its main procedure and some related tasks are presented. Numerical experiments based on the data from a subway line in China are conducted, and improved artificial bee colony is compared with a genetic algorithm. Experimental results prove the correctness of the mathematical model and the effectiveness of improved artificial bee colony, which improves regenerative energy utilization for the experimental line and performs better than genetic algorithm.


2018 ◽  
Vol 180 ◽  
pp. 02005 ◽  
Author(s):  
Włodzimierz Jefimowski ◽  
Anatolii Nikitenko

The paper presents the results of economic study of energy storage system (ESS) implemented in 3 kV DC power supply system. Two conceptions of ESS have been investigated: ESS with supercapacitor (SC) and hybrid ESS (HESS) with SC and LFP battery. The investigated locations of energy storage systems are considered among existing traction substations in two railway lines with different density of train operation. The considered aims of energy storage system implementation are decreasing of energy consumption by maximum regenerative energy utilization and reduction of peak 15- min power demand of traction substation. The paper presents a method of regenerative power estimation depending on the location of the considered ESS implementation point. Also the method of optimal location selection of ESS in terms of minimization of Simple Payback Time (SPBT) of investment is presented. Besides the influence of initial cost value as well as energy price on the SPBT value are investigated. The results are compared between two railway lines with different number of trains operating.


2018 ◽  
Vol 2018 ◽  
pp. 1-19 ◽  
Author(s):  
Ziyan Luo ◽  
Xiaoyu Li ◽  
Naihua Xiu

In this paper, we propose a sparse optimization approach to maximize the utilization of regenerative energy produced by braking trains for energy-efficient timetabling in metro railway systems. By introducing the cardinality function and the square of the Euclidean norm function as the objective function, the resulting sparse optimization model can characterize the utilization of the regenerative energy appropriately. A two-stage alternating direction method of multipliers is designed to efficiently solve the convex relaxation counterpart of the original NP-hard problem and then to produce an energy-efficient timetable of trains. The resulting approach is applied to Beijing Metro Yizhuang Line with different instances of service for case study. Comparison with the existing two-step linear program approach is also conducted which illustrates the effectiveness of our proposed sparse optimization model in terms of the energy saving rate and the efficiency of our numerical optimization algorithm in terms of computational time.


2018 ◽  
Vol 180 ◽  
pp. 02013
Author(s):  
Włodzimierz Jefimowski

The paper presents the research results of a few different conception of stationary energy storage system in a 3 kV DC system. The most attention is focused on the comparison between two topologies of the ESS: energy storage system with supercapacitor and with supercapacitor and LFP battery. The variants are compared in terms of energy saving and peak power demand reduction. The implementation of ESS with SC results the decrease of active energy drawn from traction substation. Meanwhile the implementation of ESS with SC and LFP battery leads to achieving of two aims - decreasing of active energy consumption by maximization of regenerative energy utilization and reduction of 15 - min. peak power demand of traction substation.


Sign in / Sign up

Export Citation Format

Share Document