Modeling the Winding Hot-Spot Temperature and Aging of Enclosed Vault Transformers using a Physics-Based Heat Transfer Model

Author(s):  
Poorva Bedge ◽  
James Spaulding ◽  
Daniel Zimmerle ◽  
Gerald Duggan
Author(s):  
Zhengang Zhao ◽  
Zhengyu Yang ◽  
Yuyuan Wang ◽  
Ke Liang ◽  
Nengsi Jin ◽  
...  

According to the national standard GB/T 1094.7-2008, the method of hot spot measurement of oil-immersed transformer is used to place several temperature sensors inside the gasket within the predicted hot spot position to measure the temperature of winding transformer. The highest temperature measured is regarded as the hot spot temperature of transformer. Since the winding and gasket are bad conductors of heat, there exists certain temperature difference between the gasket and the hot spot temperature of the winding. In order to ensure safe operation of transformer, the thermal environment of temperature measuring point is analyzed and the discrete equation of boundary node is established. The parameters are set according to the heat transfer mode of the oil-immersed transformer and the temperature characteristics of each heat transfer node is analyzed. Gauss-Seidel Iteration method is used to calculate the theoretical value of the measuring point of the oil-immersed transformer and the heat transfer model of the measuring point is established for further analysis. The experimental platform of the oil-immersed transformer simulator is established according to the method described in the national standard and used to measure the hot spot temperature and winding surface temperature. The results show that when the winding temperature is 77 ℃, the heat transfer model of the temperature measuring point is 74.7 ℃ and the experimental temperature of the temperature measuring point is 74.9 ℃. The error between theoretical calculation temperature and experimental temperature is 0.2. As the temperature of the experiment increases, the temperature difference between the temperature point and the winding temperature gradually increases, and the maximum absolute error is 2.1 ℃.


2018 ◽  
Vol 1 (1) ◽  
pp. 142-150
Author(s):  
Murat Tunc ◽  
Ayse Nur Esen ◽  
Doruk Sen ◽  
Ahmet Karakas

A theoretical post-dryout heat transfer model is developed for two-phase dispersed flow, one-dimensional vertical pipe in a post-CHF regime. Because of the presence of average droplet diameter lower bound in a two-phase sparse flow. Droplet diameter is also calculated. Obtained results are compared with experimental values. Experimental data is used two-phase flow steam-water in VVER-1200, reactor coolant system, reactor operating pressure is 16.2 MPa. On heater rod surface, dryout was detected as a result of jumping increase of the heater rod surface temperature. Results obtained display lower droplet dimensions than the experimentally obtained values.


2006 ◽  
Author(s):  
Filip Kitanoski ◽  
Wolfgang Puntigam ◽  
Martin Kozek ◽  
Josef Hager

2021 ◽  
Vol 71 ◽  
pp. 104456
Author(s):  
Zhuoran Zhang ◽  
Pratik Krishnan ◽  
Zeren Jiao ◽  
M. Sam Mannan ◽  
Qingsheng Wang

2016 ◽  
Vol 289 ◽  
pp. 371-380 ◽  
Author(s):  
Alexander Yu. Chebotarev ◽  
Andrey E. Kovtanyuk ◽  
Gleb V. Grenkin ◽  
Nikolai D. Botkin ◽  
Karl-Heinz Hoffmann

2005 ◽  
Vol 45 (9) ◽  
pp. 1291-1296 ◽  
Author(s):  
Hongming WANG ◽  
Guirong LI ◽  
Yucheng LEI ◽  
Yutao ZHAO ◽  
Qixun DAI ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document