An efficient method of automatic distance relay settings for transmission line protection

Author(s):  
Thanakorn Penthong ◽  
Komsan Hongesombut
Author(s):  
Win Win Tun ◽  
Ohn Zin Lin ◽  
Han Su Yin

Transmission lines are an important part of a power system. Transmission lines have high power transmission capacity and they are prone to faults of larger magnitudes. Various faults occur in transmission lines. Therefore, protection relays are necessary to protect transmission lines. The purpose of protection system is to interrupt the faulty section from the healthy section because the fault currents may damage the electrical equipments. One of the protection relays is distance relay and it is mainly used in transmission line. Sometimes these relay are used for backup protection. Distance relays for determining the impedance need the voltage and current. Transmission lines are typically protected by distance protection relay. Distance relays are considered of high speed class and can provide transmission lines. Nowadays, numerical distance relays have been used instead of using electromechanical and static distance relays. The proposed model was verified under different tests such as single line to ground (L-G) fault, double line to ground (L-L-G) fault, line to line (L-L) fault and three phase (L-L-L) fault. SimPower System was used for modelling and simulation of distance relay, transmission lines and faults. The simulation results were obtained from MATLAB software shows the feasibility of analysis of transmission line protection with mho type distance relay for single line to ground fault, double line to ground fault, line to line fault and three phase fault at different location of transmission lines. The difficulties understanding on operation of distance relay can be cleared by using MATLAB/SIMULINK software.  


2014 ◽  
Vol 705 ◽  
pp. 237-242
Author(s):  
Ramchandra P. Hasabe ◽  
Anil P. Vaidya

A new scheme to enhance the solution of the problems associated with Transmission line protection with Statcom connected is presentedin this paper.Static Synchronous Compensator (STATCOM) is a shunt type FACTS device connected at the midpoint of the transmission line to maintain the voltage atdesired level by injecting/absorbing the reactive power. This connection affects the performance of distance protection relay during line faults. Thefault detectionis carried out byusingenergy of the detail coefficients of the phase signals and artificial neutral network algorithm used for fault distance location for all thetypes of faults for transmission line. For each type of fault separate neural network is prepared for finding out the fault location.


Sign in / Sign up

Export Citation Format

Share Document